Deck 1: Mathematics and Statistics

ملء الشاشة (f)
exit full mode
سؤال
A new gamma camera/computer system that uses a new method of calculating cardiac ejection fraction (EF) is installed in a nuclear medicine department.The department decides to calculate EF for the next 25 patients on both the old gamma camera and the new gamma camera before discontinuing the use of the old camera.In the future, if it is desirable to convert the new EF value to that which would have been obtained on the old gamma camera (e.g., to assess if the patient's EF had changed), the mathematical analysis to be used is called a(n)

A)independent t-test.
B)linear regression.
C)standard error.
D)chi-square.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
If the HVL for some radionuclide in lead is 0.30 mm, what thickness of lead shielding is necessary to reduce the radiation exposure from 8 mR/hr to 1 mR/hr?

A)0.30 mm
B)0.45 mm
C)0.60 mm
D)0.90 mm
سؤال
A technologist is sitting near a bone mineral densitometer, which is a point source of x-rays.If the x-ray intensity at 1 m from the x-ray beam is 0.20 mR/hr, to what distance from the x-ray beam should the technologist move to decrease total weekly exposure to the occupational limit of 2 mR for a 40-hour workweek?

A)0.5 m
B)1.5 m
C)2.0 m
D)2.5 m
سؤال
A nuclear medicine test produces a positive test result in only 80 of the 100 patients known to be ill.Similarly, the test produces a negative test result in only 190 of the 200 patients known to be not ill.Which is correct?

A)Sensitivity = 80%, specificity = 95%, accuracy = 90%, prevalence = 33%
B)Sensitivity = 90%, specificity = 95%, accuracy = 90%, prevalence = 33%
C)Sensitivity = 90%, specificity = 80%, accuracy = 90%, prevalence = 33%
D)Sensitivity = 90%, specificity = 80%, accuracy = 70%, prevalence = 33%
سؤال
What is the standard deviation of 40,000 counts?

A)4000 counts
B)2000 counts
C)400 counts
D)200 counts
سؤال
The radiation intensity from a point source of 99mTc is 9 mR/hr at 3 m from the source.If the distance is changed to 9 m, what is the new radiation intensity?

A)0.5 mR/hr
B)1.0 mR/hr
C)2.0 mR/hr
D)3.0 mR/hr
سؤال
What is the coefficient of variation of 40,000 counts?

A)2%
B)1%
C)0.5%
D)0.25%
سؤال
One radiologist is known to be a lax reader compared with another radiologist who is known to be a strict reader.In comparing these radiologists, how would one expect their sensitivity and specificity to compare?

A)The lax reader would have lower sensitivity and higher specificity.
B)The lax reader would have higher sensitivity and lower specificity.
C)The readers would be expected to have the same sensitivity and specificity.
D)Not enough information is given to answer the question.
سؤال
How many counts should be acquired into each pixel of a nuclear medicine flood image if it is desired to be 95% confident that the true count in each pixel is within 1% of the measured counts in each pixel?

A)100,000 counts
B)40,000 counts
C)10,000 counts
D)4000 counts
سؤال
One group of 20 patients is given a drug that is thought to have an effect on kidney function, and another group of 20 patients is given a placebo (i.e., sugar pill, which is known not to have an effect on kidney function).The nuclear medicine gamma camera is used to calculate the glomerular filtration rate (GFR) in these two groups of patients.What would be the proper statistical test to use to test the hypothesis that no difference in GFR exists between these two groups of patients?

A)Chi-square test
B)Paired t-test
C)Independent t-test
D)Linear regression analysis
سؤال
The dose equivalent for occupational whole-body exposure is commonly limited to 50 mSv.How many rem is this?

A)5000 rem
B)500 rem
C)50 rem
D)5 rem
سؤال
A patient was injected with 131I on Monday at 10:00 AM.On Tuesday at 10:00 AM, the thyroid probe was placed over the thyroid and produced 100,000 counts.On Thursday at 10:00 AM, the probe showed 25,000 counts.What is the effective half-life in this patient's thyroid?

A)12 hours
B)24 hours
C)48 hours
D)72 hours
سؤال
A source of <strong>A source of   is delivered to the nuclear medicine department calibrated for 100 mCi at 8:00 AM on Monday.If this radioactivity is injected into a patient at noon on Tuesday, what radioactivity will the patient receive?</strong> A)80 mCi B)85 mCi C)90 mCi D)95 mCi <div style=padding-top: 35px> is delivered to the nuclear medicine department calibrated for 100 mCi at 8:00 AM on Monday.If this radioactivity is injected into a patient at noon on Tuesday, what radioactivity will the patient receive?

A)80 mCi
B)85 mCi
C)90 mCi
D)95 mCi
سؤال
A 99Mo-99mTc generator is calibrated for 1.00 Ci of 99Mo at 7:00 AM Monday.The generator is eluted daily Monday through Friday at 8:00 AM, but the workload is especially heavy on Friday so the generator is eluted again at 3:00 PM to obtain more 99mTc.Assuming 100% elution efficiency, how many mCi of 99mTc will be eluted at 3:00 PM Friday?

A)930 mCi
B)710 mCi
C)160 mCi
D)80 mCi
سؤال
The linear attenuation coefficient in lead for 99mTc gamma rays (140 keV) is 23 cm-1.What percentage of these gamma rays will be absorbed by a lead apron that contains 0.60 mm of lead?

A)75%
B)50%
C)25%
D)12.5%
سؤال
The gamma camera seems to be producing erratic results.A 57Co flood source is counted 10 times, producing the following count values: 1000, 975, 1032, 1096, 982, 997, 1012, 1090, 994, 977.What is the chi-square value for these counts?

A)19.3
B)18.3
C)17.3
D)16.3
سؤال
A radioactive source of 137Cs (t1/2= 30 y) was calibrated on October 23, 2000, to contain 10 μ\mu Ci.This is used as a daily accuracy check source in the dose calibrator.Presuming the dose calibrator is working properly, what activity should the dose calibrator show on April 23, 2006?

A)9.6 μ\mu Ci
B)8.8 μ\mu Ci
C)5.4 μ\mu Ci
D)2.2 μ\mu Ci
سؤال
A patient's thyroid is counted with the thyroid probe and produces 8000 counts.Then the patient is removed and background is found to be 2000 counts.The (net counts) ± (standard deviation in the net counts) in this patient is

A)10,000 ± 100 counts.
B)10,000 ± 77 counts.
C)6000 ± 77 counts.
D)6000 ± 100 counts.
سؤال
Which expression describes the operation of the gamma camera in question 16?

A)Operating properly
B)Showing too much variation
C)Showing too little variation
D)Not enough information to answer the question
سؤال
A 99Mo-99mTc generator is eluted Monday at 7:00 AM, producing 1.8 Ci of 99mTc in the eluate vial, in 20 ml saline.What volume of eluate should be withdrawn from the eluate vial into a syringe in order to inject a patient with 20 mCi of 99mTc at 3:00 PM? (Given the half-life of 99mTc is 6.02 hours.)

A)0.56 ml
B)0.66 ml
C)0.76 ml
D)0.86 ml
سؤال
What is the proper number of significant figures for the quotient (6.1 *10-2)/(0.1232)?

A)0.49513
B)0.4951
C)0.495
D)0.50
سؤال
Using the regression equation in Problem 31, if your training program exam score was 84, what does the regression equation predict for your board score?

A)92
B)82
C)72
D)62
سؤال
What is the proper number of decimal places in the sum of (0.3) + (3.5264)?

A)3.8264
B)3.826
C)3.83
D)3.8
سؤال
It is known that 75% of a radionuclide decays away in 12 hours.If starting with 10 mCi, how much will be left after 6 hours?

A)7.5 mCi
B)5 mCi
C)2.5 mCi
D)1.25 mCi
سؤال
Readers are encouraged to use Microsoft Excel to solve this problem.In a nuclear medicine technology training program, the students wonder if their final exam grade in their training program is related to their subsequent board score on the NMTCB exam.The five students attain the following pairs of scores (exam score, board score) = (72, 60), (84, 74), (88, 71), (68, 60), (91, 79).What is the linear correlation coefficient, r, between exam score and board score?

A)0.99
B)0.95
C)0.86
D)0.75
سؤال
A 5-ml sample of a standard diluted 1:10,000 produces 27,200 counts in the well counter.A 5-ml sample of patient plasma, counted for the same time as the diluted standard sample, produces 99,100 counts.What is the plasma volume?

A)10.8 liter
B)2.74 liter
C)1.73 liter
D)0.91 liter
سؤال
Convert 5 mBq to kBq and GBq.

A)50 kBq and 0.5 GBq
B)500 kBq and 0.05 GBq
C)5000 kBq and 0.005 GBq
D)5 * 104 and 5 * 10-4 GBq
سؤال
The biological half-life of 131I in a particular patient is 30 days.The physical half-life is 193 hours.If the patient's thyroid is counted with the thyroid probe detector, what effective half-life will be observed?

A)26 days
B)6.3 days
C)5.1 days
D)1.2 days
سؤال
A patient may have had a kidney function test last month that showed a kidney clearance rate of 45 milliliters per minute (ml/min).The patient returns today and has a kidney clearance rate of 60 ml/min.What is the percent increase in kidney function?

A)7%
B)14%
C)25%
D)33%
سؤال
Readers are encouraged to use Microsoft Excel to solve this problem.What is the slope and intercept in the regression equation for problem 31? (board score) = intercept + (slope) * (exam score)

A)Intercept = 7.15, slope = 0.502
B)Intercept = 6.15, slope = 0.602
C)Intercept = 5.15, slope = 0.702
D)Intercept = 4.15, slope = 0.802
سؤال
A thyroid uptake dose of 10 μ\mu Ci is equal to how much radioactivity in SI units?

A)37 kBq
B)370 kBq
C)3.7 MBq
D)37 MBq
سؤال
Readers are encouraged to use Microsoft Excel to solve this problem.What is the coefficient of variation (CV) of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)34%
B)31%
C)28%
D)12%
سؤال
Using Table 1-9 in the book, does a linear correlation coefficient r = 0.95 for n = 5 data points indicate a statistically significant linear relationship between the x and y variables?

A)Yes
B)No
C)There is not enough information to answer the question.
D)None
سؤال
A source of 18F (t1/2 = approximately 2 hr) is noted to contain 3 mCi at noon.What was the radioactivity at 8:00 AM that same day?

A)24 mCi
B)18 mCi
C)12 mCi
D)6 mCi
سؤال
Readers are encouraged to use Microsoft Excel to solve this problem.What is the standard deviation of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)4.02
B)3.26
C)2.15
D)1.92
سؤال
Using Table 1-9 in the book, what is the P value for the linear correlation coefficient r in question 31?

A)P = 0.001
B)0.01 < P < 0.05
C)0.05 < P < 0.1
D)P > 0.10
سؤال
A radioactive source decays from 20 mCi to 2.5 mCi in 18 hours.What is the physical half-life?

A)8 hours
B)7 hours
C)6 hours
D)5 hours
سؤال
A long-lived radioactive source is counted for 1 minute and yields 10,000 counts.If this source is counted immediately again, there is a 95% probability that the result will be in the range:

A)9950 to 10,050
B)9900 to 10,100
C)9800 to 10,200
D)9700 to 10,300
سؤال
Readers are encouraged to use Microsoft Excel to solve this problem.What is the mean of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)9.01
B)6.28
C)5.97
D)4.83
سؤال
A sample shows a count rate of 36,000 cpm during a 3-minute counting period.Express this as the count rate ± standard deviation.

A)36,000 ± 220 cpm
B)36,000 ± 110 cpm
C)12,000 ± 55 cpm
D)12,000 ± 28 cpm
سؤال
The morning elution of the 99Mo-99mTc generator yields 850 mCi of 99mTc radioactivity in 20 ml of saline eluate.What volume should be withdrawn from the eluate vial into a patient syringe to immediately perform a 25-mCi patient scan?

A)0.2 ml
B)0.30 ml
C)0.59 ml
D)1.7 ml
سؤال
An intensity setting of 250 on a display screen may produce a suitable image for a bar phantom with 500K counts in the acquisition.Now it is desired to change to 350K counts in the image.The intensity on the screen is known to change linearly with the intensity control setting.What intensity setting should be used for the new 350K-count image?

A)100,000
B)150,000
C)175,000
D)200,000
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/42
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 1: Mathematics and Statistics
1
A new gamma camera/computer system that uses a new method of calculating cardiac ejection fraction (EF) is installed in a nuclear medicine department.The department decides to calculate EF for the next 25 patients on both the old gamma camera and the new gamma camera before discontinuing the use of the old camera.In the future, if it is desirable to convert the new EF value to that which would have been obtained on the old gamma camera (e.g., to assess if the patient's EF had changed), the mathematical analysis to be used is called a(n)

A)independent t-test.
B)linear regression.
C)standard error.
D)chi-square.
linear regression.
2
If the HVL for some radionuclide in lead is 0.30 mm, what thickness of lead shielding is necessary to reduce the radiation exposure from 8 mR/hr to 1 mR/hr?

A)0.30 mm
B)0.45 mm
C)0.60 mm
D)0.90 mm
0.90 mm
3
A technologist is sitting near a bone mineral densitometer, which is a point source of x-rays.If the x-ray intensity at 1 m from the x-ray beam is 0.20 mR/hr, to what distance from the x-ray beam should the technologist move to decrease total weekly exposure to the occupational limit of 2 mR for a 40-hour workweek?

A)0.5 m
B)1.5 m
C)2.0 m
D)2.5 m
0.5 m
4
A nuclear medicine test produces a positive test result in only 80 of the 100 patients known to be ill.Similarly, the test produces a negative test result in only 190 of the 200 patients known to be not ill.Which is correct?

A)Sensitivity = 80%, specificity = 95%, accuracy = 90%, prevalence = 33%
B)Sensitivity = 90%, specificity = 95%, accuracy = 90%, prevalence = 33%
C)Sensitivity = 90%, specificity = 80%, accuracy = 90%, prevalence = 33%
D)Sensitivity = 90%, specificity = 80%, accuracy = 70%, prevalence = 33%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is the standard deviation of 40,000 counts?

A)4000 counts
B)2000 counts
C)400 counts
D)200 counts
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
6
The radiation intensity from a point source of 99mTc is 9 mR/hr at 3 m from the source.If the distance is changed to 9 m, what is the new radiation intensity?

A)0.5 mR/hr
B)1.0 mR/hr
C)2.0 mR/hr
D)3.0 mR/hr
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
7
What is the coefficient of variation of 40,000 counts?

A)2%
B)1%
C)0.5%
D)0.25%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
8
One radiologist is known to be a lax reader compared with another radiologist who is known to be a strict reader.In comparing these radiologists, how would one expect their sensitivity and specificity to compare?

A)The lax reader would have lower sensitivity and higher specificity.
B)The lax reader would have higher sensitivity and lower specificity.
C)The readers would be expected to have the same sensitivity and specificity.
D)Not enough information is given to answer the question.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
9
How many counts should be acquired into each pixel of a nuclear medicine flood image if it is desired to be 95% confident that the true count in each pixel is within 1% of the measured counts in each pixel?

A)100,000 counts
B)40,000 counts
C)10,000 counts
D)4000 counts
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
10
One group of 20 patients is given a drug that is thought to have an effect on kidney function, and another group of 20 patients is given a placebo (i.e., sugar pill, which is known not to have an effect on kidney function).The nuclear medicine gamma camera is used to calculate the glomerular filtration rate (GFR) in these two groups of patients.What would be the proper statistical test to use to test the hypothesis that no difference in GFR exists between these two groups of patients?

A)Chi-square test
B)Paired t-test
C)Independent t-test
D)Linear regression analysis
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
11
The dose equivalent for occupational whole-body exposure is commonly limited to 50 mSv.How many rem is this?

A)5000 rem
B)500 rem
C)50 rem
D)5 rem
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
12
A patient was injected with 131I on Monday at 10:00 AM.On Tuesday at 10:00 AM, the thyroid probe was placed over the thyroid and produced 100,000 counts.On Thursday at 10:00 AM, the probe showed 25,000 counts.What is the effective half-life in this patient's thyroid?

A)12 hours
B)24 hours
C)48 hours
D)72 hours
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
13
A source of <strong>A source of   is delivered to the nuclear medicine department calibrated for 100 mCi at 8:00 AM on Monday.If this radioactivity is injected into a patient at noon on Tuesday, what radioactivity will the patient receive?</strong> A)80 mCi B)85 mCi C)90 mCi D)95 mCi is delivered to the nuclear medicine department calibrated for 100 mCi at 8:00 AM on Monday.If this radioactivity is injected into a patient at noon on Tuesday, what radioactivity will the patient receive?

A)80 mCi
B)85 mCi
C)90 mCi
D)95 mCi
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
14
A 99Mo-99mTc generator is calibrated for 1.00 Ci of 99Mo at 7:00 AM Monday.The generator is eluted daily Monday through Friday at 8:00 AM, but the workload is especially heavy on Friday so the generator is eluted again at 3:00 PM to obtain more 99mTc.Assuming 100% elution efficiency, how many mCi of 99mTc will be eluted at 3:00 PM Friday?

A)930 mCi
B)710 mCi
C)160 mCi
D)80 mCi
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
15
The linear attenuation coefficient in lead for 99mTc gamma rays (140 keV) is 23 cm-1.What percentage of these gamma rays will be absorbed by a lead apron that contains 0.60 mm of lead?

A)75%
B)50%
C)25%
D)12.5%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
16
The gamma camera seems to be producing erratic results.A 57Co flood source is counted 10 times, producing the following count values: 1000, 975, 1032, 1096, 982, 997, 1012, 1090, 994, 977.What is the chi-square value for these counts?

A)19.3
B)18.3
C)17.3
D)16.3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
17
A radioactive source of 137Cs (t1/2= 30 y) was calibrated on October 23, 2000, to contain 10 μ\mu Ci.This is used as a daily accuracy check source in the dose calibrator.Presuming the dose calibrator is working properly, what activity should the dose calibrator show on April 23, 2006?

A)9.6 μ\mu Ci
B)8.8 μ\mu Ci
C)5.4 μ\mu Ci
D)2.2 μ\mu Ci
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
18
A patient's thyroid is counted with the thyroid probe and produces 8000 counts.Then the patient is removed and background is found to be 2000 counts.The (net counts) ± (standard deviation in the net counts) in this patient is

A)10,000 ± 100 counts.
B)10,000 ± 77 counts.
C)6000 ± 77 counts.
D)6000 ± 100 counts.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
19
Which expression describes the operation of the gamma camera in question 16?

A)Operating properly
B)Showing too much variation
C)Showing too little variation
D)Not enough information to answer the question
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
20
A 99Mo-99mTc generator is eluted Monday at 7:00 AM, producing 1.8 Ci of 99mTc in the eluate vial, in 20 ml saline.What volume of eluate should be withdrawn from the eluate vial into a syringe in order to inject a patient with 20 mCi of 99mTc at 3:00 PM? (Given the half-life of 99mTc is 6.02 hours.)

A)0.56 ml
B)0.66 ml
C)0.76 ml
D)0.86 ml
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
21
What is the proper number of significant figures for the quotient (6.1 *10-2)/(0.1232)?

A)0.49513
B)0.4951
C)0.495
D)0.50
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
22
Using the regression equation in Problem 31, if your training program exam score was 84, what does the regression equation predict for your board score?

A)92
B)82
C)72
D)62
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
23
What is the proper number of decimal places in the sum of (0.3) + (3.5264)?

A)3.8264
B)3.826
C)3.83
D)3.8
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
24
It is known that 75% of a radionuclide decays away in 12 hours.If starting with 10 mCi, how much will be left after 6 hours?

A)7.5 mCi
B)5 mCi
C)2.5 mCi
D)1.25 mCi
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
25
Readers are encouraged to use Microsoft Excel to solve this problem.In a nuclear medicine technology training program, the students wonder if their final exam grade in their training program is related to their subsequent board score on the NMTCB exam.The five students attain the following pairs of scores (exam score, board score) = (72, 60), (84, 74), (88, 71), (68, 60), (91, 79).What is the linear correlation coefficient, r, between exam score and board score?

A)0.99
B)0.95
C)0.86
D)0.75
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
26
A 5-ml sample of a standard diluted 1:10,000 produces 27,200 counts in the well counter.A 5-ml sample of patient plasma, counted for the same time as the diluted standard sample, produces 99,100 counts.What is the plasma volume?

A)10.8 liter
B)2.74 liter
C)1.73 liter
D)0.91 liter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
27
Convert 5 mBq to kBq and GBq.

A)50 kBq and 0.5 GBq
B)500 kBq and 0.05 GBq
C)5000 kBq and 0.005 GBq
D)5 * 104 and 5 * 10-4 GBq
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
28
The biological half-life of 131I in a particular patient is 30 days.The physical half-life is 193 hours.If the patient's thyroid is counted with the thyroid probe detector, what effective half-life will be observed?

A)26 days
B)6.3 days
C)5.1 days
D)1.2 days
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
29
A patient may have had a kidney function test last month that showed a kidney clearance rate of 45 milliliters per minute (ml/min).The patient returns today and has a kidney clearance rate of 60 ml/min.What is the percent increase in kidney function?

A)7%
B)14%
C)25%
D)33%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
30
Readers are encouraged to use Microsoft Excel to solve this problem.What is the slope and intercept in the regression equation for problem 31? (board score) = intercept + (slope) * (exam score)

A)Intercept = 7.15, slope = 0.502
B)Intercept = 6.15, slope = 0.602
C)Intercept = 5.15, slope = 0.702
D)Intercept = 4.15, slope = 0.802
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
31
A thyroid uptake dose of 10 μ\mu Ci is equal to how much radioactivity in SI units?

A)37 kBq
B)370 kBq
C)3.7 MBq
D)37 MBq
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
32
Readers are encouraged to use Microsoft Excel to solve this problem.What is the coefficient of variation (CV) of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)34%
B)31%
C)28%
D)12%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
33
Using Table 1-9 in the book, does a linear correlation coefficient r = 0.95 for n = 5 data points indicate a statistically significant linear relationship between the x and y variables?

A)Yes
B)No
C)There is not enough information to answer the question.
D)None
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
34
A source of 18F (t1/2 = approximately 2 hr) is noted to contain 3 mCi at noon.What was the radioactivity at 8:00 AM that same day?

A)24 mCi
B)18 mCi
C)12 mCi
D)6 mCi
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
35
Readers are encouraged to use Microsoft Excel to solve this problem.What is the standard deviation of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)4.02
B)3.26
C)2.15
D)1.92
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
36
Using Table 1-9 in the book, what is the P value for the linear correlation coefficient r in question 31?

A)P = 0.001
B)0.01 < P < 0.05
C)0.05 < P < 0.1
D)P > 0.10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
37
A radioactive source decays from 20 mCi to 2.5 mCi in 18 hours.What is the physical half-life?

A)8 hours
B)7 hours
C)6 hours
D)5 hours
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
38
A long-lived radioactive source is counted for 1 minute and yields 10,000 counts.If this source is counted immediately again, there is a 95% probability that the result will be in the range:

A)9950 to 10,050
B)9900 to 10,100
C)9800 to 10,200
D)9700 to 10,300
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
39
Readers are encouraged to use Microsoft Excel to solve this problem.What is the mean of the following five numbers: 6.40, 7.20, 3.50, 9.20, 5.10?

A)9.01
B)6.28
C)5.97
D)4.83
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
40
A sample shows a count rate of 36,000 cpm during a 3-minute counting period.Express this as the count rate ± standard deviation.

A)36,000 ± 220 cpm
B)36,000 ± 110 cpm
C)12,000 ± 55 cpm
D)12,000 ± 28 cpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
41
The morning elution of the 99Mo-99mTc generator yields 850 mCi of 99mTc radioactivity in 20 ml of saline eluate.What volume should be withdrawn from the eluate vial into a patient syringe to immediately perform a 25-mCi patient scan?

A)0.2 ml
B)0.30 ml
C)0.59 ml
D)1.7 ml
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
42
An intensity setting of 250 on a display screen may produce a suitable image for a bar phantom with 500K counts in the acquisition.Now it is desired to change to 350K counts in the image.The intensity on the screen is known to change linearly with the intensity control setting.What intensity setting should be used for the new 350K-count image?

A)100,000
B)150,000
C)175,000
D)200,000
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.