Deck 11: Instrumentation

ملء الشاشة (f)
exit full mode
سؤال
Which survey meter is appropriate to use when measuring high levels of radiation?

A)Ionization chamber
B)Dose calibrator
C)GM meter
D)Body badge
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The gas in a dose calibrator is usually

A)air.
B)helium.
C)argon.
D)quenching.
سؤال
When performing quality control on a well counter or thyroid probe, constancy is tested by performing a(n)

A)chi-square test.
B)FWHM.
C)intrinsic resolution check.
D)count for each radionuclide used.
سؤال
Quenching gas is used in a(n)

A)dose calibrator.
B)Geiger-Mueller (GM) detector.
C)ionization chamber.
D)pocket dosimeter.
سؤال
Intrinsic efficiency is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system characterized by point spread function and line spread function.
سؤال
When performing quality control on a dose calibrator, it is required that the accuracy test is performed

A)daily.
B)quarterly.
C)annually.
D)at installation.
سؤال
Spatial resolution is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system characterized by point spread function and line spread function.
سؤال
The percent full width at half maximum (FWHM) is often used as a measure of

A)precision.
B)sensitivity.
C)intensity.
D)resolution.
سؤال
When performing quality control on a dose calibrator, the testing of the correct activity over the entire range of radioactivity used in the laboratory is the

A)accuracy test.
B)geometry test.
C)linearity test.
D)constancy test.
سؤال
The anticoincidence component on a pulse-height analyzer determines if

A)more than one photon at the same energy is counted.
B)two photons are counted at the same time.
C)the lower discriminator is triggered, but not the upper energy discriminator.
D)the upper and lower energy discriminators are triggered simultaneously.
سؤال
In a scintillation camera, geometric resolution depends on

A)the size of the patient.
B)the position of the source.
C)the configuration of the holes in a collimator.
D)filtering the image.
سؤال
A PHA includes all of the following EXCEPT

A)lower-level discriminator.
B)upper-level discriminator.
C)anticoincidence circuit.
D)amplifier.
سؤال
When performing quality control on a well counter or thyroid probe, energy resolution is evaluated

A)weekly.
B)monthly.
C)quarterly.
D)annually.
سؤال
When performing quality control on a dose calibrator, it is recommended to test geometry:

A)daily.
B)quarterly.
C)annually.
D)at installation.
سؤال
For a parallel-hole collimator, spatial resolution degrades as

A)the source-to-collimator distance increases.
B)the source-to-collimator distance decreases.
C)the collimator holes decrease in size.
D)the collimator holes increase in number.
سؤال
Extrinsic spatial resolution is monitored using

A)FWHM.
B)quadrant bar phantom.
C)flat field collimator.
D)electronic zoom.
سؤال
When performing quality control on a dose calibrator, it is required that the constancy test is performed

A)daily.
B)quarterly.
C)annually.
D)at installation.
سؤال
Geometric efficiency is defined

A)as the ratio of the number of detected events to the number of source emissions.
B)as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)as the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)as the amount of blurring that is produced by an imaging system, characterized by point spread function and line spread function.
سؤال
Which detector is confined for use in detecting radiation where the exposure levels are below 2000 mR/hr?

A)Ionization chamber
B)Dose calibrator
C)GM meter
D)Body badge
سؤال
Detector efficiency is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)the geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system, characterized by point spread function and line spread function.
سؤال
In the reconstruction of SPECT images, segmenting refers to

A)volume rendering.
B)determining the number of counts per pixel.
C)separating the organ from the background or nearby structures.
D)dividing an organ into different components.
سؤال
The devices that operate in the saturation range include all of the following EXCEPT

A)dose calibrator.
B)ionization chamber.
C)personnel dosimeters.
D)Geiger-Mueller counter.
سؤال
A low-pass filter

A)allows low frequencies to pass and blocks high frequencies.
B)blocks low frequencies and allows high frequencies to pass.
C)smoothes images by reducing low frequencies.
D)reduces noise by blocking low frequencies.
سؤال
Quench gas is used in a Geiger-Mueller counter to

A)enhance ionizations.
B)stop the discharge.
C)alter the voltage.
D)improve the counting of alphas.
سؤال
When the same nonuniformity is back-projected at each of the angles of acquisition, the result is

A)blurring.
B)a star artifact.
C)a ring artifact.
D)streak artifact.
سؤال
If a detector can produce an electronic signal for each individual interaction whose amplitude reflects the amount of energy absorbed, it is said to have spatial resolution.
سؤال
Body contouring or elliptical orbits in SPECT imaging have an advantage over circular orbits because they

A)improve the accuracy of gantry location.
B)reduce the camera-to-patient distance.
C)maximize resolution.
D)minimize noise.
سؤال
Compared to a low-energy collimator, a high-energy collimator will have all of the following EXCEPT

A)thicker septa.
B)longer holes.
C)lower resolution.
D)higher sensitivity.
سؤال
Increased sensitivity for SPECT imaging can be achieved by using a

A)general-purpose collimator.
B)converging collimator.
C)high-energy collimator.
D)high-resolution collimator.
سؤال
In SPECT/CT imaging, it is best if the patient does shallow breathing throughout the scan.
سؤال
When referring to image quality, contrast

A)refers to how well objects can be separated in space.
B)determines whether two objects have different activity concentrations.
C)refers to the ability to see the edge of a structure.
D)occurs because of the random nature of counting statistics.
سؤال
The center-of-rotation measurement

A)determines the number of projections.
B)corresponds to the pixel size at the center of the orbit.
C)corresponds to the radius.
D)determines the offset between the camera center and projections.
سؤال
Ramp-filtered projections are characterized by

A)a star artifact.
B)edge information enhancement.
C)smoothing of edge information.
D)enhancing noise.
سؤال
In multihole low-energy collimators, longer and smaller holes produce

A)better uniformity.
B)better sensitivity.
C)better intrinsic resolution.
D)better spatial resolution.
سؤال
Digitization of the signal of each photomultiplier tube (PMT)

A)increases sensitivity.
B)decreases scan time.
C)increases contrast.
D)increases processing flexibility.
سؤال
When referring to image quality, resolution

A)refers to how well objects can be separated in space.
B)determines whether two objects have different activity concentrations.
C)refers to the ability to see the edge of a structure.
D)occurs because of the random nature of counting statistics.
سؤال
In general, the pixel size should be less than:

A)one-quarter the system resolution.
B)one-third the system resolution.
C)one-quarter the system efficiency.
D)one-third the system efficiency.
سؤال
The 360-degree orbit is most often used in SPECT studies EXCEPT for scans of

A)the brain.
B)the heart.
C)the liver.
D)bone.
سؤال
According to the Nuclear Regulatory Commission (NRC), survey meters must be calibrated:

A)daily.
B)monthly.
C)quarterly.
D)annually.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/39
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Instrumentation
1
Which survey meter is appropriate to use when measuring high levels of radiation?

A)Ionization chamber
B)Dose calibrator
C)GM meter
D)Body badge
Ionization chamber
2
The gas in a dose calibrator is usually

A)air.
B)helium.
C)argon.
D)quenching.
argon.
3
When performing quality control on a well counter or thyroid probe, constancy is tested by performing a(n)

A)chi-square test.
B)FWHM.
C)intrinsic resolution check.
D)count for each radionuclide used.
chi-square test.
4
Quenching gas is used in a(n)

A)dose calibrator.
B)Geiger-Mueller (GM) detector.
C)ionization chamber.
D)pocket dosimeter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
5
Intrinsic efficiency is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system characterized by point spread function and line spread function.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
6
When performing quality control on a dose calibrator, it is required that the accuracy test is performed

A)daily.
B)quarterly.
C)annually.
D)at installation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
7
Spatial resolution is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system characterized by point spread function and line spread function.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
8
The percent full width at half maximum (FWHM) is often used as a measure of

A)precision.
B)sensitivity.
C)intensity.
D)resolution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
9
When performing quality control on a dose calibrator, the testing of the correct activity over the entire range of radioactivity used in the laboratory is the

A)accuracy test.
B)geometry test.
C)linearity test.
D)constancy test.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
10
The anticoincidence component on a pulse-height analyzer determines if

A)more than one photon at the same energy is counted.
B)two photons are counted at the same time.
C)the lower discriminator is triggered, but not the upper energy discriminator.
D)the upper and lower energy discriminators are triggered simultaneously.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
11
In a scintillation camera, geometric resolution depends on

A)the size of the patient.
B)the position of the source.
C)the configuration of the holes in a collimator.
D)filtering the image.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
12
A PHA includes all of the following EXCEPT

A)lower-level discriminator.
B)upper-level discriminator.
C)anticoincidence circuit.
D)amplifier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
13
When performing quality control on a well counter or thyroid probe, energy resolution is evaluated

A)weekly.
B)monthly.
C)quarterly.
D)annually.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
14
When performing quality control on a dose calibrator, it is recommended to test geometry:

A)daily.
B)quarterly.
C)annually.
D)at installation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
15
For a parallel-hole collimator, spatial resolution degrades as

A)the source-to-collimator distance increases.
B)the source-to-collimator distance decreases.
C)the collimator holes decrease in size.
D)the collimator holes increase in number.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
16
Extrinsic spatial resolution is monitored using

A)FWHM.
B)quadrant bar phantom.
C)flat field collimator.
D)electronic zoom.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
17
When performing quality control on a dose calibrator, it is required that the constancy test is performed

A)daily.
B)quarterly.
C)annually.
D)at installation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
18
Geometric efficiency is defined

A)as the ratio of the number of detected events to the number of source emissions.
B)as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)as the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)as the amount of blurring that is produced by an imaging system, characterized by point spread function and line spread function.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
19
Which detector is confined for use in detecting radiation where the exposure levels are below 2000 mR/hr?

A)Ionization chamber
B)Dose calibrator
C)GM meter
D)Body badge
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
20
Detector efficiency is defined as

A)the ratio of the number of detected events to the number of source emissions.
B)the geometric efficiency and is defined as the fraction of emitted photons (gamma or x-rays) that hit the detector; it depends on the detector configuration and its distance from the source.
C)the fraction of gamma rays that are detected when they hit the detector; it depends on the thickness (t) and attenuation coefficient ( μ\mu ) of the detecting material.
D)the amount of blurring that is produced by an imaging system, characterized by point spread function and line spread function.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
21
In the reconstruction of SPECT images, segmenting refers to

A)volume rendering.
B)determining the number of counts per pixel.
C)separating the organ from the background or nearby structures.
D)dividing an organ into different components.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
22
The devices that operate in the saturation range include all of the following EXCEPT

A)dose calibrator.
B)ionization chamber.
C)personnel dosimeters.
D)Geiger-Mueller counter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
23
A low-pass filter

A)allows low frequencies to pass and blocks high frequencies.
B)blocks low frequencies and allows high frequencies to pass.
C)smoothes images by reducing low frequencies.
D)reduces noise by blocking low frequencies.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
24
Quench gas is used in a Geiger-Mueller counter to

A)enhance ionizations.
B)stop the discharge.
C)alter the voltage.
D)improve the counting of alphas.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
25
When the same nonuniformity is back-projected at each of the angles of acquisition, the result is

A)blurring.
B)a star artifact.
C)a ring artifact.
D)streak artifact.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
26
If a detector can produce an electronic signal for each individual interaction whose amplitude reflects the amount of energy absorbed, it is said to have spatial resolution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
27
Body contouring or elliptical orbits in SPECT imaging have an advantage over circular orbits because they

A)improve the accuracy of gantry location.
B)reduce the camera-to-patient distance.
C)maximize resolution.
D)minimize noise.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
28
Compared to a low-energy collimator, a high-energy collimator will have all of the following EXCEPT

A)thicker septa.
B)longer holes.
C)lower resolution.
D)higher sensitivity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
29
Increased sensitivity for SPECT imaging can be achieved by using a

A)general-purpose collimator.
B)converging collimator.
C)high-energy collimator.
D)high-resolution collimator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
30
In SPECT/CT imaging, it is best if the patient does shallow breathing throughout the scan.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
31
When referring to image quality, contrast

A)refers to how well objects can be separated in space.
B)determines whether two objects have different activity concentrations.
C)refers to the ability to see the edge of a structure.
D)occurs because of the random nature of counting statistics.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
32
The center-of-rotation measurement

A)determines the number of projections.
B)corresponds to the pixel size at the center of the orbit.
C)corresponds to the radius.
D)determines the offset between the camera center and projections.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
33
Ramp-filtered projections are characterized by

A)a star artifact.
B)edge information enhancement.
C)smoothing of edge information.
D)enhancing noise.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
34
In multihole low-energy collimators, longer and smaller holes produce

A)better uniformity.
B)better sensitivity.
C)better intrinsic resolution.
D)better spatial resolution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
35
Digitization of the signal of each photomultiplier tube (PMT)

A)increases sensitivity.
B)decreases scan time.
C)increases contrast.
D)increases processing flexibility.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
36
When referring to image quality, resolution

A)refers to how well objects can be separated in space.
B)determines whether two objects have different activity concentrations.
C)refers to the ability to see the edge of a structure.
D)occurs because of the random nature of counting statistics.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
37
In general, the pixel size should be less than:

A)one-quarter the system resolution.
B)one-third the system resolution.
C)one-quarter the system efficiency.
D)one-third the system efficiency.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
38
The 360-degree orbit is most often used in SPECT studies EXCEPT for scans of

A)the brain.
B)the heart.
C)the liver.
D)bone.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
39
According to the Nuclear Regulatory Commission (NRC), survey meters must be calibrated:

A)daily.
B)monthly.
C)quarterly.
D)annually.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 39 في هذه المجموعة.