Deck 18: Controllogix Controllers - Part 4 - Programming Counters

ملء الشاشة (f)
exit full mode
سؤال
A CTD counter will cause the accumulated value to ____ when there is a false to true transition of the counter rung.

A)reset to zero
B)increase by one
C)decrease by one
D)remain the same
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The ControlLogix CTD instruction is typically used with a CTU instruction that references:

A)the same counter structure.
B)a different counter structure.
C)the same data table.
D)a different data table.
سؤال
A counter counts the change of state of an external trigger signal.
سؤال
A counter retains its Accum value if the rung goes false.
سؤال
The acronym CTU stands for a count- up counter.
سؤال
For the counter instruction shown,what is the counter's tag name? <strong>For the counter instruction shown,what is the counter's tag name?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum <div style=padding-top: 35px>

A)Count Up
B)Package_Counter
C)Preset
D)Accum
سؤال
The counter Accum value is reset to zero by a:

A)RES instruction with a different tag name.
B)RES instruction with the same tag name.
C)true to false transition of the counter rung.
D)false to true transition of the counter rung.
سؤال
For the counter instruction shown,which parameter specifies the value the counter must reach before the done bit turns on? <strong>For the counter instruction shown,which parameter specifies the value the counter must reach before the done bit turns on?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum <div style=padding-top: 35px>

A)Count Up
B)Package_Counter
C)Preset
D)Accum
سؤال
The two basic counter types are the right-counter and the left-counter.
سؤال
All counters are non-retentive.
سؤال
The acronym CTD stands for a count- down counter.
سؤال
Counters count:

A)true-to-false transitions of the counter rung.
B)false-to-true transitions of the counter rung.
C)the length of time a counter rung is true.
D)the length of time a counter rung is false.
سؤال
For the counter instruction shown,which parameter indicates the number of transitions of the counter rung? <strong>For the counter instruction shown,which parameter indicates the number of transitions of the counter rung?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum <div style=padding-top: 35px>

A)Count Up
B)Package_Counter
C)Preset
D)Accum
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/13
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 18: Controllogix Controllers - Part 4 - Programming Counters
1
A CTD counter will cause the accumulated value to ____ when there is a false to true transition of the counter rung.

A)reset to zero
B)increase by one
C)decrease by one
D)remain the same
C
2
The ControlLogix CTD instruction is typically used with a CTU instruction that references:

A)the same counter structure.
B)a different counter structure.
C)the same data table.
D)a different data table.
A
3
A counter counts the change of state of an external trigger signal.
True
4
A counter retains its Accum value if the rung goes false.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
5
The acronym CTU stands for a count- up counter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
6
For the counter instruction shown,what is the counter's tag name? <strong>For the counter instruction shown,what is the counter's tag name?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum

A)Count Up
B)Package_Counter
C)Preset
D)Accum
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
7
The counter Accum value is reset to zero by a:

A)RES instruction with a different tag name.
B)RES instruction with the same tag name.
C)true to false transition of the counter rung.
D)false to true transition of the counter rung.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
8
For the counter instruction shown,which parameter specifies the value the counter must reach before the done bit turns on? <strong>For the counter instruction shown,which parameter specifies the value the counter must reach before the done bit turns on?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum

A)Count Up
B)Package_Counter
C)Preset
D)Accum
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
9
The two basic counter types are the right-counter and the left-counter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
10
All counters are non-retentive.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
11
The acronym CTD stands for a count- down counter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
12
Counters count:

A)true-to-false transitions of the counter rung.
B)false-to-true transitions of the counter rung.
C)the length of time a counter rung is true.
D)the length of time a counter rung is false.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
13
For the counter instruction shown,which parameter indicates the number of transitions of the counter rung? <strong>For the counter instruction shown,which parameter indicates the number of transitions of the counter rung?  </strong> A)Count Up B)Package_Counter C)Preset D)Accum

A)Count Up
B)Package_Counter
C)Preset
D)Accum
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 13 في هذه المجموعة.