Deck 21: Simulator Design

ملء الشاشة (f)
exit full mode
سؤال
________________________ takes into consideration how an area on the other side of an irradiated wall is going to be used.

A) Workload
B) Occupancy factor
C) Use factor
D) Barrier factor
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A light field radiation field coincidence test is performed in all instances except:

A) when a bulb is replaced
B) when the mirror is realigned
C) when the radiation field appears off center from the film
سؤال
Light photons are produced and transmitted electronically through to a video image at the:

A) output phosphor
B) tube housing
C) photocathode
D) focusing lenses
سؤال
The patient couch table top is created out of this material,which has a low density and low x-ray absorption:

A) plastic carbonate
B) carbon fiber
C) steel
D) polystyrene
سؤال
In the conventional simulator,the _____________ represents the radiation field.

A) blades
B) wires
C) ODI
D) collimator assembly
سؤال
To reduce magnification during fluoroscopy,the image intensifier should be:

A) moved as close to the patient as possible
B) moved as far as possible from the patient
C) rotated in the direction of the central ray
D) centered
سؤال
The accessory holder on the simulator may serve which of the following purposes?
I)function as an electron cone adapter
II)simulate custom block verification
III)absorb scatter radiation from thicker body parts
IV)provide scanning movements for the imaging system

A) I and II only
B) I and III only
C) II and IV only
D) I,II,III,and IV
سؤال
Which of the following represents the path of a photon when it enters the image intensifier?

A) input phosphor,electrostatic lenses,photocathode,anode,output screen
B) input phosphor,photocathode,electrostatic lenses,anode,output screen
C) input phosphor,anode,electrostatic lenses,photocathode,output screen
D) anode,input phosphor,electrostatic lenses,photocathode,output screen
سؤال
Conventional simulators are designed to simulate the ____________,geometric,and optical properties of a variety of treatment units.

A) x-ray
B) mechanical
C) comfort
D) linear design
سؤال
Positioning lasers are located: I.side (lateral)
II)overhead
III)sagittal
IV)coronal

A) I and II
B) I,II,and III
C) II and III
D) all of the above
سؤال
A light field radiation field coincidence test verifies:

A) that the light from the blades represents the radiation field
B) that the field wires define the radiation field
C) the symmetry of the radiation beam
D) all of the above
سؤال
_____________________ takes into consideration how much a machine will run in a normal week.

A) Workload
B) Occupancy factor
C) Use factor
D) Barrier factor
سؤال
Which of the following is true about an isocenter?
I)It is a single point in space.
II)The gantry rotates around the isocenter.
III)The axis of gantry rotation,collimator rotation,and treatment couch rotation meet.
IV)Lasers are aligned at the isocenter.

A) I and II
B) II and III
C) III and IV
D) I,II,III,and IV
سؤال
When determining the shielding requirements for a simulation room,thicker shielding is needed in the _____________.

A) primary walls
B) secondary walls
C) tertiary walls
D) ceiling
سؤال
One 50-keV photon at the input screen can be converted into _____________ light photons at the output screen.

A) 10,000
B) 20,000
C) 100,000
D) 200,000
سؤال
The conventional simulator can define treatment fields by using:

A) blades
B) wires
C) ODI
D) collimator assembly
سؤال
Digital fluoroscopy is similar to conventional fluoroscopy; however,there is a ________________ to transmit the electrical charge.

A) charge capture device
B) computer capture detector
C) computer coupled detector
D) charge coupled device
سؤال
Most patient support assemblies can support approximately ____ lbs.

A) 250
B) 350
C) 450
D) 550
سؤال
When the primary x-ray beams strike the input screen of the image intensifier,what is emitted?

A) electrons
B) light
C) photons
D) protons
سؤال
The ___________________ in the image intensifier emits electrons when it is stimulated by light photons.

A) input phosphor
B) output phosphor
C) photocathode
D) electrostatic lenses
سؤال
As recommended by Martin,to produce a high-quality digital radiograph,slice thickness and spacing should be ___ mm through the region containing the tumor.

A) 1
B) 2
C) 3
D) 4
سؤال
The matrix size is determined by the number of:

A) voxels
B) Hounsfield units
C) detectors on the scanner
D) pixels
سؤال
The difference in completing an axial scan as compared to spiral CT is that the:

A) aperture size is larger in an axial scanner
B) detector size is larger in the spiral CT scanner
C) gantry is rotating in a diagonal
D) table moves for the spiral CT
سؤال
CT numbers are also known as:

A) Hounsfield units
B) Godfrey units
C) attenuation coefficient units
سؤال
The CT number for dense bone is:

A) -1000
B) -100
C) 0
D) 1000
سؤال
As the field of view increases and the matrix size remains constant,the spatial resolution:

A) increases
B) decreases
C) stays the same
سؤال
A(n)____________ allows the computed tomography (CT)x-ray tube to rotate in a continuous motion without the concern of cables becoming tangled.

A) spiral ring
B) slip ring
C) aperture ring
D) electrical power ring
سؤال
The CT number for water is:

A) -1000
B) -100
C) 0
D) 1000
سؤال
Most CT scanners today are _______-generation imaging systems.

A) first
B) second
C) third
D) fourth
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/29
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 21: Simulator Design
1
________________________ takes into consideration how an area on the other side of an irradiated wall is going to be used.

A) Workload
B) Occupancy factor
C) Use factor
D) Barrier factor
B
Occupancy factor will vary if the room adjacent to the simulator is a closet or has an employee there for 40 hours per week.
2
A light field radiation field coincidence test is performed in all instances except:

A) when a bulb is replaced
B) when the mirror is realigned
C) when the radiation field appears off center from the film
C
A light field radiation field coincidence test is not performed if the radiation field appears off center from the film.The image intensifier is probably off center.
3
Light photons are produced and transmitted electronically through to a video image at the:

A) output phosphor
B) tube housing
C) photocathode
D) focusing lenses
A
The light photons are converted from electrons at the output phosphor,which is then converted into an electronic image on a television screen.
4
The patient couch table top is created out of this material,which has a low density and low x-ray absorption:

A) plastic carbonate
B) carbon fiber
C) steel
D) polystyrene
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
5
In the conventional simulator,the _____________ represents the radiation field.

A) blades
B) wires
C) ODI
D) collimator assembly
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
6
To reduce magnification during fluoroscopy,the image intensifier should be:

A) moved as close to the patient as possible
B) moved as far as possible from the patient
C) rotated in the direction of the central ray
D) centered
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
7
The accessory holder on the simulator may serve which of the following purposes?
I)function as an electron cone adapter
II)simulate custom block verification
III)absorb scatter radiation from thicker body parts
IV)provide scanning movements for the imaging system

A) I and II only
B) I and III only
C) II and IV only
D) I,II,III,and IV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which of the following represents the path of a photon when it enters the image intensifier?

A) input phosphor,electrostatic lenses,photocathode,anode,output screen
B) input phosphor,photocathode,electrostatic lenses,anode,output screen
C) input phosphor,anode,electrostatic lenses,photocathode,output screen
D) anode,input phosphor,electrostatic lenses,photocathode,output screen
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
9
Conventional simulators are designed to simulate the ____________,geometric,and optical properties of a variety of treatment units.

A) x-ray
B) mechanical
C) comfort
D) linear design
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
10
Positioning lasers are located: I.side (lateral)
II)overhead
III)sagittal
IV)coronal

A) I and II
B) I,II,and III
C) II and III
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
11
A light field radiation field coincidence test verifies:

A) that the light from the blades represents the radiation field
B) that the field wires define the radiation field
C) the symmetry of the radiation beam
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
12
_____________________ takes into consideration how much a machine will run in a normal week.

A) Workload
B) Occupancy factor
C) Use factor
D) Barrier factor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following is true about an isocenter?
I)It is a single point in space.
II)The gantry rotates around the isocenter.
III)The axis of gantry rotation,collimator rotation,and treatment couch rotation meet.
IV)Lasers are aligned at the isocenter.

A) I and II
B) II and III
C) III and IV
D) I,II,III,and IV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
14
When determining the shielding requirements for a simulation room,thicker shielding is needed in the _____________.

A) primary walls
B) secondary walls
C) tertiary walls
D) ceiling
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
15
One 50-keV photon at the input screen can be converted into _____________ light photons at the output screen.

A) 10,000
B) 20,000
C) 100,000
D) 200,000
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
16
The conventional simulator can define treatment fields by using:

A) blades
B) wires
C) ODI
D) collimator assembly
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
17
Digital fluoroscopy is similar to conventional fluoroscopy; however,there is a ________________ to transmit the electrical charge.

A) charge capture device
B) computer capture detector
C) computer coupled detector
D) charge coupled device
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
18
Most patient support assemblies can support approximately ____ lbs.

A) 250
B) 350
C) 450
D) 550
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
19
When the primary x-ray beams strike the input screen of the image intensifier,what is emitted?

A) electrons
B) light
C) photons
D) protons
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
20
The ___________________ in the image intensifier emits electrons when it is stimulated by light photons.

A) input phosphor
B) output phosphor
C) photocathode
D) electrostatic lenses
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
21
As recommended by Martin,to produce a high-quality digital radiograph,slice thickness and spacing should be ___ mm through the region containing the tumor.

A) 1
B) 2
C) 3
D) 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
22
The matrix size is determined by the number of:

A) voxels
B) Hounsfield units
C) detectors on the scanner
D) pixels
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
23
The difference in completing an axial scan as compared to spiral CT is that the:

A) aperture size is larger in an axial scanner
B) detector size is larger in the spiral CT scanner
C) gantry is rotating in a diagonal
D) table moves for the spiral CT
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
24
CT numbers are also known as:

A) Hounsfield units
B) Godfrey units
C) attenuation coefficient units
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
25
The CT number for dense bone is:

A) -1000
B) -100
C) 0
D) 1000
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
26
As the field of view increases and the matrix size remains constant,the spatial resolution:

A) increases
B) decreases
C) stays the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
27
A(n)____________ allows the computed tomography (CT)x-ray tube to rotate in a continuous motion without the concern of cables becoming tangled.

A) spiral ring
B) slip ring
C) aperture ring
D) electrical power ring
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
28
The CT number for water is:

A) -1000
B) -100
C) 0
D) 1000
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
29
Most CT scanners today are _______-generation imaging systems.

A) first
B) second
C) third
D) fourth
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.