Deck 4: Technical Aspects of the Ekg

ملء الشاشة (f)
exit full mode
سؤال
If artifact is present in leads I,II,and AVR,the most likely source of the artifact is on the

A)Right arm.
B)Left arm.
C)Right leg.
D)Left leg.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Somatic tremor artifact is commonly caused by

A)Patient movement.
B)Respirations.
C)Lotion on the skin interfering with the signal.
D)Electrical interference.
سؤال
Your patient is smiling and visiting with family,but the cardiac monitor shows that the patient's heart has completely stopped.The rhythm on the monitor is thus

A)Artifact.
B)A life-threatening emergency.
C)Dangerous,but it can wait awhile.
D)"Toothbrush tachycardia."
سؤال
The most important benefit of a three-channel recorder when doing a 12-lead EKG is

A)It is less work for the technician.
B)All leads can be recorded simultaneously.
C)Three leads can be recorded before changing the paper.
D)It is less painful for the patient.
سؤال
Muscle artifact can be minimized by monitoring the patient in lead

A)I.
B)II.
C)AVR.
D)V1 or MCL1.
سؤال
Muscle artifact is seen most often in

A)The precordial leads.
B)The frontal leads.
C)Leads whose positive electrode is on the right leg.
D)Leads whose negative electrode is on the right arm.
سؤال
Your patient for a 12-lead EKG has no legs as a result of bilateral amputations.Where should you put the leg electrodes?

A)On the arms
B)On the lower abdomen above where the legs would be
C)On the artificial legs
D)On the upper chest
سؤال
The artifact caused by the jiggling of wires during toothbrushing is called

A)CPR artifact.
B)"Toothbrush asystole."
C)PVCs.
D)"Toothbrush Tachycardia."
سؤال
Your patient is having chills.What kind of artifact can this produce?

A)60-cycle interference
B)Baseline sway
C)Broken recording
D)Somatic tremors
سؤال
Some modern EKG machines are Bluetooth-capable,allowing EMS workers to

A)Listen to their favorite music station while on the job.
B)Control the artifact on the EKG.
C)Hear the EKG's interpretation via special headphones.
D)Transmit the EKG to the nearest hospital so workers can prepare for the patient's arrival.
سؤال
Electrical shock is LEAST likely to be caused by which of the following?

A)Frayed electrical cord on the EKG machine
B)Broken grounding prong on the electrical cord
C)Properly maintained EKG machine
D)Ungrounded hospital bed on which the patient is lying
سؤال
If your patient's cardiac rhythm is life-threatening,your FIRST action should be to

A)Check the monitor wires and patches.
B)Exchange the cardiac monitor for a new one.
C)Check the patient-assess vital signs and see how he/she feels.
D)Notify the family of the patient's deteriorating condition.
سؤال
On your patient's 12-lead EKG,lead I's waves and complexes are completely negative.AVR's waves and complexes are completely positive.The most likely cause of this is

A)Dextrocardia (Heart is on the right side of the body instead of the left).
B)Axis deviation from an MI.
C)Axis deviation from ventricular tachycardia.
D)Right and left arm leads inadvertently reversed.
سؤال
If there is artifact in leads II,III,and AVF,on which limb(s)would you expect to find the cause of the artifact?

A)Right arm
B)Right arm and left leg
C)Left leg
D)Left arm
سؤال
The "gain" setting on the EKG machine is concerned with

A)The amplitude of the waves and complexes.
B)The size of the patient.
C)Einthoven's law.
D)Electrical conduction through the bundle branches.
سؤال
A digital converter on the EKG machine

A)Controls the amount of artifact.
B)Controls the calibration of the machine.
C)Is the pen that prints out the EKG tracing.
D)Converts the analog signal to a digital one.
سؤال
Normal paper speed for printing out the EKG is

A)25 mm/sec.
B)50 mm/sec.
C)10 mm/sec.
D)20 mm/sec.
سؤال
A patient is short of breath and his nurse tells you he must have the head of bed (HOB)at 90 degrees for his 12-lead EKG.You

A)Leave,telling the nurse to call you when the HOB can be lowered flat.
B)Roll the HOB flat and do the EKG,then roll the HOB back up.
C)Call the physician and ask why the HOB can't be lowered.
D)Do the EKG at 90 degrees and document this position on the EKG.
سؤال
The most common cause for the P wave,QRS complex,and T wave to be inverted in lead I is

A)Dextrocardia.
B)Incorrect lead placement.
C)Myocardial infarction.
D)Left bundle branch block.
سؤال
Sixty-cycle interference is commonly caused by

A)Patient movement.
B)Respirations.
C)Lotion on the skin interfering with the signal.
D)Electrical interference.
سؤال
Electrically speaking,the heart is a

A)Transmitter.
B)Receiver.
C)Cable.
D)Galvanometer.
سؤال
Small adhesive patches with conductive gel on the skin side are

A)Cables.
B)Electrodes.
C)Conduits.
D)Oscilloscopes.
سؤال
Using an EKG machine with frayed wires is not dangerous if the wires are taped together.
سؤال
Artifact is a sign that the patient is in distress.
سؤال
It is possible to have artifact in the midst of a dangerous rhythm.
سؤال
Macroshock and microshock are two kinds of electrical shock the patient can sustain from faulty equipment.
سؤال
CPR artifact is seen only during CPR.
سؤال
Artifact is an unwanted interference or jitter on the EKG tracing.
سؤال
If artifact is seen in leads I,III,and AVL,the problem is on which limb?

A)Right arm
B)Right leg
C)Left arm
D)Left leg
سؤال
Life-threatening dysrhythmias will cause symptoms of decreased cardiac output.
سؤال
Artifact can mimic dysrhythmias.
سؤال
"Toothbrush tachycardia" can be lethal.
سؤال
Artifact in Leads I,III,and AVL is caused by a loose or detached electrode patch or wire on the left arm.
سؤال
To minimize artifact,what must be done?

A)Attach electrode patches securely
B)Tell the patient not to breathe during the EKG
C)Tell the patient not to move during the EKG
D)All but B
سؤال
Artifact does not cause symptoms of decreased cardiac output.
سؤال
Sometimes,the presence of artifact can be verified by changing the lead.
سؤال
If you think the rhythm is artifact,check your patient for any symptoms of decreased cardiac output first,then check his monitor wires and patches and observe the rhythm in another lead.
سؤال
Microshock is different from macroshock in that microshock is

A)A higher-voltage electrical shock.
B)A lower-voltage electrical shock.
C)Caused by inadequate grounding of electrical equipment.
D)Incapable of causing death.
سؤال
A rhythm that looks lethal cannot be artifact.
سؤال
Chills can cause somatic tremor artifact.
سؤال
Broken recording is caused by _____.
سؤال
If artifact is seen in leads I,III,and AVL,you should direct your corrective efforts to which limb or limbs? _____.
سؤال
Electrically speaking,the EKG machine is a _____ and the heart is a transmitter.
سؤال
The EKG machine control feature that controls the size of the waves and complexes is the _____.
سؤال
The word "somatic" means _____.
سؤال
A thick-looking pattern on the EKG paper that looks like someone used a thick Magic Marker to write the baseline is typical of what kind of artifact? _____.
سؤال
Baseline sway is caused by lotion or sweat on the skin interfering with the _____ reaching the EKG machine.
سؤال
Troubleshooting involves determining and alleviating the cause of _____.
سؤال
CPR artifact is caused by chest compressions obscuring the real _______.
سؤال
_____ is unwanted jitter or interference on the EKG tracing.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/50
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 4: Technical Aspects of the Ekg
1
If artifact is present in leads I,II,and AVR,the most likely source of the artifact is on the

A)Right arm.
B)Left arm.
C)Right leg.
D)Left leg.
A
2
Somatic tremor artifact is commonly caused by

A)Patient movement.
B)Respirations.
C)Lotion on the skin interfering with the signal.
D)Electrical interference.
A
3
Your patient is smiling and visiting with family,but the cardiac monitor shows that the patient's heart has completely stopped.The rhythm on the monitor is thus

A)Artifact.
B)A life-threatening emergency.
C)Dangerous,but it can wait awhile.
D)"Toothbrush tachycardia."
A
4
The most important benefit of a three-channel recorder when doing a 12-lead EKG is

A)It is less work for the technician.
B)All leads can be recorded simultaneously.
C)Three leads can be recorded before changing the paper.
D)It is less painful for the patient.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
5
Muscle artifact can be minimized by monitoring the patient in lead

A)I.
B)II.
C)AVR.
D)V1 or MCL1.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
6
Muscle artifact is seen most often in

A)The precordial leads.
B)The frontal leads.
C)Leads whose positive electrode is on the right leg.
D)Leads whose negative electrode is on the right arm.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
7
Your patient for a 12-lead EKG has no legs as a result of bilateral amputations.Where should you put the leg electrodes?

A)On the arms
B)On the lower abdomen above where the legs would be
C)On the artificial legs
D)On the upper chest
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
8
The artifact caused by the jiggling of wires during toothbrushing is called

A)CPR artifact.
B)"Toothbrush asystole."
C)PVCs.
D)"Toothbrush Tachycardia."
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
9
Your patient is having chills.What kind of artifact can this produce?

A)60-cycle interference
B)Baseline sway
C)Broken recording
D)Somatic tremors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
10
Some modern EKG machines are Bluetooth-capable,allowing EMS workers to

A)Listen to their favorite music station while on the job.
B)Control the artifact on the EKG.
C)Hear the EKG's interpretation via special headphones.
D)Transmit the EKG to the nearest hospital so workers can prepare for the patient's arrival.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
11
Electrical shock is LEAST likely to be caused by which of the following?

A)Frayed electrical cord on the EKG machine
B)Broken grounding prong on the electrical cord
C)Properly maintained EKG machine
D)Ungrounded hospital bed on which the patient is lying
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
12
If your patient's cardiac rhythm is life-threatening,your FIRST action should be to

A)Check the monitor wires and patches.
B)Exchange the cardiac monitor for a new one.
C)Check the patient-assess vital signs and see how he/she feels.
D)Notify the family of the patient's deteriorating condition.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
13
On your patient's 12-lead EKG,lead I's waves and complexes are completely negative.AVR's waves and complexes are completely positive.The most likely cause of this is

A)Dextrocardia (Heart is on the right side of the body instead of the left).
B)Axis deviation from an MI.
C)Axis deviation from ventricular tachycardia.
D)Right and left arm leads inadvertently reversed.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
14
If there is artifact in leads II,III,and AVF,on which limb(s)would you expect to find the cause of the artifact?

A)Right arm
B)Right arm and left leg
C)Left leg
D)Left arm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
15
The "gain" setting on the EKG machine is concerned with

A)The amplitude of the waves and complexes.
B)The size of the patient.
C)Einthoven's law.
D)Electrical conduction through the bundle branches.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
16
A digital converter on the EKG machine

A)Controls the amount of artifact.
B)Controls the calibration of the machine.
C)Is the pen that prints out the EKG tracing.
D)Converts the analog signal to a digital one.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
17
Normal paper speed for printing out the EKG is

A)25 mm/sec.
B)50 mm/sec.
C)10 mm/sec.
D)20 mm/sec.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
18
A patient is short of breath and his nurse tells you he must have the head of bed (HOB)at 90 degrees for his 12-lead EKG.You

A)Leave,telling the nurse to call you when the HOB can be lowered flat.
B)Roll the HOB flat and do the EKG,then roll the HOB back up.
C)Call the physician and ask why the HOB can't be lowered.
D)Do the EKG at 90 degrees and document this position on the EKG.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
19
The most common cause for the P wave,QRS complex,and T wave to be inverted in lead I is

A)Dextrocardia.
B)Incorrect lead placement.
C)Myocardial infarction.
D)Left bundle branch block.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
20
Sixty-cycle interference is commonly caused by

A)Patient movement.
B)Respirations.
C)Lotion on the skin interfering with the signal.
D)Electrical interference.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
21
Electrically speaking,the heart is a

A)Transmitter.
B)Receiver.
C)Cable.
D)Galvanometer.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
22
Small adhesive patches with conductive gel on the skin side are

A)Cables.
B)Electrodes.
C)Conduits.
D)Oscilloscopes.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
23
Using an EKG machine with frayed wires is not dangerous if the wires are taped together.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
24
Artifact is a sign that the patient is in distress.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
25
It is possible to have artifact in the midst of a dangerous rhythm.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
26
Macroshock and microshock are two kinds of electrical shock the patient can sustain from faulty equipment.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
27
CPR artifact is seen only during CPR.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
28
Artifact is an unwanted interference or jitter on the EKG tracing.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
29
If artifact is seen in leads I,III,and AVL,the problem is on which limb?

A)Right arm
B)Right leg
C)Left arm
D)Left leg
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
30
Life-threatening dysrhythmias will cause symptoms of decreased cardiac output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
31
Artifact can mimic dysrhythmias.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
32
"Toothbrush tachycardia" can be lethal.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
33
Artifact in Leads I,III,and AVL is caused by a loose or detached electrode patch or wire on the left arm.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
34
To minimize artifact,what must be done?

A)Attach electrode patches securely
B)Tell the patient not to breathe during the EKG
C)Tell the patient not to move during the EKG
D)All but B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
35
Artifact does not cause symptoms of decreased cardiac output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
36
Sometimes,the presence of artifact can be verified by changing the lead.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
37
If you think the rhythm is artifact,check your patient for any symptoms of decreased cardiac output first,then check his monitor wires and patches and observe the rhythm in another lead.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
38
Microshock is different from macroshock in that microshock is

A)A higher-voltage electrical shock.
B)A lower-voltage electrical shock.
C)Caused by inadequate grounding of electrical equipment.
D)Incapable of causing death.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
39
A rhythm that looks lethal cannot be artifact.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
40
Chills can cause somatic tremor artifact.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
41
Broken recording is caused by _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
42
If artifact is seen in leads I,III,and AVL,you should direct your corrective efforts to which limb or limbs? _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
43
Electrically speaking,the EKG machine is a _____ and the heart is a transmitter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
44
The EKG machine control feature that controls the size of the waves and complexes is the _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
45
The word "somatic" means _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
46
A thick-looking pattern on the EKG paper that looks like someone used a thick Magic Marker to write the baseline is typical of what kind of artifact? _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
47
Baseline sway is caused by lotion or sweat on the skin interfering with the _____ reaching the EKG machine.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
48
Troubleshooting involves determining and alleviating the cause of _____.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
49
CPR artifact is caused by chest compressions obscuring the real _______.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
50
_____ is unwanted jitter or interference on the EKG tracing.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.