Deck 4: Factors Affecting Radiographic Quality

ملء الشاشة (f)
exit full mode
سؤال
Which of these statements is FALSE?

A) Structures should be magnified to enhance interpretation.
B) An area of interest must be recorded completely with sufficient surrounding structures for a frame of reference.
C) A radiograph should be of proper density, contrast, and definition.
D) An image should be free of errors.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Which of the following indicates a radiographic image that is black and white with few shades of gray in between?

A) Short resolution
B) Long resolution
C) Short scale
D) Long scale
سؤال
An original radiograph is exposed at 8 mA for 1.0 seconds. If the mA is increased to 10, which of the following exposure times would be correct to maintain radiographic density?

A) 0.4
B) 0.6
C) 0.8
D) 1.0
سؤال
Each of the following results in image unsharpness EXCEPT one. Which one is the EXCEPTION?

A) Patient movement during exposure
B) Image receptor positioned close to the teeth
C) A short PID
D) The use of intensifying screens
سؤال
Each of the following is a term used to describe visual image characteristics EXCEPT one. Which one is the EXCEPTION?

A) Sharpness
B) Contrast
C) Milliamperage
D) Density
سؤال
A radiographic film with a small crystal size

A) creates sharpness.
B) causes magnification.
C) decreases exposure time.
D) increases contrast.
سؤال
Which of these is NOT a shadow-casting principle?

A) A large focal spot
B) Long target-image receptor distance
C) Short object-image receptor distance
D) Parallel object-image receptor relationship
سؤال
Which of these statements regarding radiographic contrast is FALSE?

A) There are few shades of gray in a radiograph with short-scale contrast.
B) Short-scale contrast describes a radiograph in which the density differences between adjacent areas are large.
C) There are many shades of gray in a radiograph with long-scale contrast.
D) Long-scale contrast describes a radiograph in which the density differences between adjacent areas are large.
سؤال
Which of the following is recommended for increasing radiographic contrast while maintaining radiographic density?

A) Increase kVp and increase exposure time.
B) Decrease kVp and decrease exposure time.
C) Increase kVp and decrease exposure time.
D) Decrease kVp and increase exposure time.
سؤال
Image magnification can be decreased by:

A) increasing the target-object distance.
B) increasing the object-image receptor distance.
C) decreasing the target-surface distance.
D) increasing the focal spot size.
سؤال
Which of the following statements about dental radiographic exposure variables is true?

A) Increasing the mA darkens the radiograph.
B) Decreasing exposure time darkens the radiograph.
C) Exposure time is difficult to change on most machines.
D) Milliamperage affects radiographic contrast.
سؤال
Which of the following refers to a radiographic image that is black and white with many shades of gray in between?

A) Low contrast
B) High contrast
C) Low density
D) High density
سؤال
When changing the PID length from 8 inches (20.5 cm) to 16 inches (41 cm), what corresponding change must be made to maintain image density?

A) Decrease exposure time.
B) Increase exposure time.
C) Decrease kilovoltage.
D) Increase kilovoltage.
سؤال
The inverse square law states that the intensity of the radiation:

A) increases as the distance from its source increases because the beam of radiation converges.
B) decreases as the distance away from its source increases because the beam of radiation diverges.
C) increases as the distance away from its source increases because the beam of radiation diverges.
D) decreases as the distance away from its source increases because the beam of radiation converges.
سؤال
Which kVp setting produces long-scale image contrast?

A) 65 kVp
B) 75 kVp
C) 85 kVp
D) 95 kVp
سؤال
The difference in densities between adjacent areas on the radiograph is termed:

A) sharpness.
B) density.
C) resolution.
D) contrast.
سؤال
Which of these statements is FALSE?

A) Increasing the target-image receptor distance reduces penumbra.
B) Radiation intensity is directly proportional to the square of the distance from the source.
C) A long PID increases image sharpness.
D) A recessed tube increases the target-image receptor distance.
سؤال
Radiolucent images appear dark or black because:

A) hard radiation was allowed to reach the image receptor.
B) dense structures stopped x-rays from reaching the image receptor.
C) soft radiation was stopped before reaching the image receptor.
D) less dense structures permitted more x-rays to reach the image receptor.
سؤال
The degree of overall blackness of a radiographic image is termed:

A) sharpness.
B) density.
C) resolution.
D) contrast.
سؤال
Each of the following appear radiopaque EXCEPT one. Which one is the EXCEPTION?

A) Bone
B) Dentin
C) Pulp
D) Enamel
سؤال
Radiographic density (film darkening) is decreased when the milliamperage or exposure time is increased.
سؤال
The term "short-scale contrast" describes a radiograph in which density differences between adjacent areas are small.
سؤال
That portion of the radiographic image that appears light is called "radiolucent."
سؤال
Theoretically, the ideal focal spot would be a point source.
سؤال
Only one film should be placed in contact with the intensifying screens used for extraoral radiography.
سؤال
Grids absorb scattered x-rays.
سؤال
Slight movement of the tube head during exposure of a radiograph effectively increases the size of the focal spot on the target within the tube head.
سؤال
Thicker intensifying screens increase the sharpness of extraoral radiographs.
سؤال
A small focal spot reduces penumbra.
سؤال
White areas on a radiographic image are termed radiolucent.
سؤال
Some clinicians prefer a radiographic image that is of low contrast, and others prefer a radiographic image that is of high contrast.
سؤال
Sharpness/definition refers to the detail and clarity of the structures on a radiograph.
سؤال
Radiographic image unsharpness is generally caused by movement of the patient, image receptor, or tube head during exposure.
سؤال
The film should be in close physical contact with the intensifying screens.
سؤال
Digital imaging sharpness can be affected by pixel size and distribution.
سؤال
The target-object distance is the distance between the focal spot on the target and the skin surface of the patient.
سؤال
The target-image receptor distance should be short to create radiographs with the best definition.
سؤال
Penumbra is a device used in extraoral radiography to prevent scatter radiation from fogging the image receptor.
سؤال
A radiographic image with many shades of gray is said to have low contrast.
سؤال
Increasing the kVP results in a more penetrating x-ray beam.
سؤال
What is radiographic density?
سؤال
What is long-scale contrast?
سؤال
What is penumbra?
سؤال
What types of tissues or structures appear radiopaque on radiographs?
سؤال
The quality of the beam of radiation is determined by which exposure factor?
سؤال
What types of tissues or structures appear radiolucent on radiographs?
سؤال
Why should the x-ray film be placed parallel to the long axis of the tooth?
سؤال
What is the relationship between kVp and contrast?
سؤال
What is short-scale contrast?
سؤال
What is radiographic contrast?
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/50
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 4: Factors Affecting Radiographic Quality
1
Which of these statements is FALSE?

A) Structures should be magnified to enhance interpretation.
B) An area of interest must be recorded completely with sufficient surrounding structures for a frame of reference.
C) A radiograph should be of proper density, contrast, and definition.
D) An image should be free of errors.
Structures should be magnified to enhance interpretation.
2
Which of the following indicates a radiographic image that is black and white with few shades of gray in between?

A) Short resolution
B) Long resolution
C) Short scale
D) Long scale
Short scale
3
An original radiograph is exposed at 8 mA for 1.0 seconds. If the mA is increased to 10, which of the following exposure times would be correct to maintain radiographic density?

A) 0.4
B) 0.6
C) 0.8
D) 1.0
0.8
4
Each of the following results in image unsharpness EXCEPT one. Which one is the EXCEPTION?

A) Patient movement during exposure
B) Image receptor positioned close to the teeth
C) A short PID
D) The use of intensifying screens
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
5
Each of the following is a term used to describe visual image characteristics EXCEPT one. Which one is the EXCEPTION?

A) Sharpness
B) Contrast
C) Milliamperage
D) Density
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
6
A radiographic film with a small crystal size

A) creates sharpness.
B) causes magnification.
C) decreases exposure time.
D) increases contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of these is NOT a shadow-casting principle?

A) A large focal spot
B) Long target-image receptor distance
C) Short object-image receptor distance
D) Parallel object-image receptor relationship
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which of these statements regarding radiographic contrast is FALSE?

A) There are few shades of gray in a radiograph with short-scale contrast.
B) Short-scale contrast describes a radiograph in which the density differences between adjacent areas are large.
C) There are many shades of gray in a radiograph with long-scale contrast.
D) Long-scale contrast describes a radiograph in which the density differences between adjacent areas are large.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
9
Which of the following is recommended for increasing radiographic contrast while maintaining radiographic density?

A) Increase kVp and increase exposure time.
B) Decrease kVp and decrease exposure time.
C) Increase kVp and decrease exposure time.
D) Decrease kVp and increase exposure time.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
10
Image magnification can be decreased by:

A) increasing the target-object distance.
B) increasing the object-image receptor distance.
C) decreasing the target-surface distance.
D) increasing the focal spot size.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
11
Which of the following statements about dental radiographic exposure variables is true?

A) Increasing the mA darkens the radiograph.
B) Decreasing exposure time darkens the radiograph.
C) Exposure time is difficult to change on most machines.
D) Milliamperage affects radiographic contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
12
Which of the following refers to a radiographic image that is black and white with many shades of gray in between?

A) Low contrast
B) High contrast
C) Low density
D) High density
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
13
When changing the PID length from 8 inches (20.5 cm) to 16 inches (41 cm), what corresponding change must be made to maintain image density?

A) Decrease exposure time.
B) Increase exposure time.
C) Decrease kilovoltage.
D) Increase kilovoltage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
14
The inverse square law states that the intensity of the radiation:

A) increases as the distance from its source increases because the beam of radiation converges.
B) decreases as the distance away from its source increases because the beam of radiation diverges.
C) increases as the distance away from its source increases because the beam of radiation diverges.
D) decreases as the distance away from its source increases because the beam of radiation converges.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
15
Which kVp setting produces long-scale image contrast?

A) 65 kVp
B) 75 kVp
C) 85 kVp
D) 95 kVp
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
16
The difference in densities between adjacent areas on the radiograph is termed:

A) sharpness.
B) density.
C) resolution.
D) contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
17
Which of these statements is FALSE?

A) Increasing the target-image receptor distance reduces penumbra.
B) Radiation intensity is directly proportional to the square of the distance from the source.
C) A long PID increases image sharpness.
D) A recessed tube increases the target-image receptor distance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
18
Radiolucent images appear dark or black because:

A) hard radiation was allowed to reach the image receptor.
B) dense structures stopped x-rays from reaching the image receptor.
C) soft radiation was stopped before reaching the image receptor.
D) less dense structures permitted more x-rays to reach the image receptor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
19
The degree of overall blackness of a radiographic image is termed:

A) sharpness.
B) density.
C) resolution.
D) contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
20
Each of the following appear radiopaque EXCEPT one. Which one is the EXCEPTION?

A) Bone
B) Dentin
C) Pulp
D) Enamel
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
21
Radiographic density (film darkening) is decreased when the milliamperage or exposure time is increased.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
22
The term "short-scale contrast" describes a radiograph in which density differences between adjacent areas are small.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
23
That portion of the radiographic image that appears light is called "radiolucent."
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
24
Theoretically, the ideal focal spot would be a point source.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
25
Only one film should be placed in contact with the intensifying screens used for extraoral radiography.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
26
Grids absorb scattered x-rays.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
27
Slight movement of the tube head during exposure of a radiograph effectively increases the size of the focal spot on the target within the tube head.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
28
Thicker intensifying screens increase the sharpness of extraoral radiographs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
29
A small focal spot reduces penumbra.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
30
White areas on a radiographic image are termed radiolucent.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
31
Some clinicians prefer a radiographic image that is of low contrast, and others prefer a radiographic image that is of high contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
32
Sharpness/definition refers to the detail and clarity of the structures on a radiograph.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
33
Radiographic image unsharpness is generally caused by movement of the patient, image receptor, or tube head during exposure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
34
The film should be in close physical contact with the intensifying screens.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
35
Digital imaging sharpness can be affected by pixel size and distribution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
36
The target-object distance is the distance between the focal spot on the target and the skin surface of the patient.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
37
The target-image receptor distance should be short to create radiographs with the best definition.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
38
Penumbra is a device used in extraoral radiography to prevent scatter radiation from fogging the image receptor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
39
A radiographic image with many shades of gray is said to have low contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
40
Increasing the kVP results in a more penetrating x-ray beam.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
41
What is radiographic density?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
42
What is long-scale contrast?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
43
What is penumbra?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
44
What types of tissues or structures appear radiopaque on radiographs?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
45
The quality of the beam of radiation is determined by which exposure factor?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
46
What types of tissues or structures appear radiolucent on radiographs?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
47
Why should the x-ray film be placed parallel to the long axis of the tooth?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
48
What is the relationship between kVp and contrast?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
49
What is short-scale contrast?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
50
What is radiographic contrast?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.