سؤال
Aspirin-induced bleeding and Willebrand disease (VWD), type 1, are detected reliably by:

A) Bleeding time
B) Point-of-care testing (POCT)
C) PFA 100 Platelet Function Analyzer
D) Nephelometry
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Which single instrument development has been the most important improvement in coagulation instrumentation?

A) Multiple-sample dilutions
B) Improved flagging
C) Random access testing
D) Graphing of clot formation
سؤال
Which of the following assays uses indirect measurement using a chromogenic substrate to quantitate heparin?

A) Protein C
B) Thrombin time (TT)
C) Anti-Xa assay
D) Fibrinogen assay
سؤال
Examples of instrument malfunction flags include all of the following except:

A) Temperature error
B) Probe not aspirating
C) No end point detected
D) Hemolysis
سؤال
Using which principle does plasma become more opaque as a clot forms and the amount of light being detected decreases?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
سؤال
Automatic performance of certain tests based on the results of other tests is called:

A) Reflex testing
B) Interpretive liberty
C) Programming flexibility
D) Random access
سؤال
Who should select the coagulation instruments for a given laboratory?

A) Laboratory director
B) Department manager
C) Clinical laboratory scientists
D) All of the previously listed individuals working together
سؤال
Which of the following is the most common clot detection principle used for coagulation testing?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
سؤال
Diagnostica Stago coagulation instruments are based on what clot detection principle?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Nephelometric
سؤال
Which of the following most improved safety for laboratory scientists?

A) Closed tube sampling
B) Random access
C) Expanded computer capabilities
D) Improved flagging capabilities
سؤال
All of the following are considered routine coagulation tests that are available in most large and small clinical laboratories except:

A) Prothrombin time (PT)
B) Fibrinogen assay
C) Partial thromboplastin time (PTT)
D) Antithrombin assay
سؤال
What is the greatest disadvantage to photo-optical coagulation instruments?

A) High cost
B) Complexity of operation
C) Availability is limited
D) Interference from lipemia, hemolysis, and hyperbilirubinemia
سؤال
Which of the following principles measures the actual coagulation protein rather than fibrin formation?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
سؤال
Which of the following is true regarding advances in automated coagulation instrumentation?

A) Less staff training is required to operate and maintain the equipment than earlier semiautomatic instruments.
B) Single-sample testing is possible because of increased precision.
C) Newer instruments are less expensive.
D) Accuracy is so improved that controls do not need to be run.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 47: Coagulation Instrumentation
1
Aspirin-induced bleeding and Willebrand disease (VWD), type 1, are detected reliably by:

A) Bleeding time
B) Point-of-care testing (POCT)
C) PFA 100 Platelet Function Analyzer
D) Nephelometry
PFA 100 Platelet Function Analyzer
2
Which single instrument development has been the most important improvement in coagulation instrumentation?

A) Multiple-sample dilutions
B) Improved flagging
C) Random access testing
D) Graphing of clot formation
Random access testing
3
Which of the following assays uses indirect measurement using a chromogenic substrate to quantitate heparin?

A) Protein C
B) Thrombin time (TT)
C) Anti-Xa assay
D) Fibrinogen assay
Anti-Xa assay
4
Examples of instrument malfunction flags include all of the following except:

A) Temperature error
B) Probe not aspirating
C) No end point detected
D) Hemolysis
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
5
Using which principle does plasma become more opaque as a clot forms and the amount of light being detected decreases?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
6
Automatic performance of certain tests based on the results of other tests is called:

A) Reflex testing
B) Interpretive liberty
C) Programming flexibility
D) Random access
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
7
Who should select the coagulation instruments for a given laboratory?

A) Laboratory director
B) Department manager
C) Clinical laboratory scientists
D) All of the previously listed individuals working together
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which of the following is the most common clot detection principle used for coagulation testing?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
9
Diagnostica Stago coagulation instruments are based on what clot detection principle?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Nephelometric
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
10
Which of the following most improved safety for laboratory scientists?

A) Closed tube sampling
B) Random access
C) Expanded computer capabilities
D) Improved flagging capabilities
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
11
All of the following are considered routine coagulation tests that are available in most large and small clinical laboratories except:

A) Prothrombin time (PT)
B) Fibrinogen assay
C) Partial thromboplastin time (PTT)
D) Antithrombin assay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
12
What is the greatest disadvantage to photo-optical coagulation instruments?

A) High cost
B) Complexity of operation
C) Availability is limited
D) Interference from lipemia, hemolysis, and hyperbilirubinemia
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following principles measures the actual coagulation protein rather than fibrin formation?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which of the following is true regarding advances in automated coagulation instrumentation?

A) Less staff training is required to operate and maintain the equipment than earlier semiautomatic instruments.
B) Single-sample testing is possible because of increased precision.
C) Newer instruments are less expensive.
D) Accuracy is so improved that controls do not need to be run.