Requirements in 517.40(C) through 517.44 do not apply to freestanding buildings used as nursing homes and limited care facilities, provided that ____.
Question 2
Multiple Choice
Generator accessories, including but not limited to the ____, electrically operated louvers, and other generator accessories essential for generator operation, shall be arranged for automatic connection to the alternate power source and connected to the life safety branch.
Question 3
Multiple Choice
A system of feeders and branch circuits supplying power for lighting, receptacles, and equipment essential for life safety that is automatically connected to alternate power sources by one or more transfer switches during interruption of the normal power source is called a ____.
Question 4
Multiple Choice
For essential electrical systems under ____, deletion of the time-lag intervals feature for delayed automatic connection to the equipment branch shall be permitted.
Question 5
Multiple Choice
All branch circuits serving patient care spaces shall be provided with a(n) ____ by installation in a metal raceway system or a cable having a metallic armor or sheath assembly.
Question 6
Multiple Choice
At least one of the receptacles of a patient bed location must be connected to (1) the normal system branch circuit as required or (2) a critical branch circuit supplied by ____ not associated with other receptacles at the same patient bed location.
Question 7
Multiple Choice
Critical care spaces served from ____ shall not be required to have circuits from the normal system.
Question 8
Multiple Choice
Essential electrical systems for hospitals shall be comprised of ____ capable of supplying a limited amount of lighting and power service that is considered essential for life and safety and effective hospital operation during the time the normal electrical service is interrupted for any reason.
Question 9
Multiple Choice
Branch circuits serving only special-purpose outlets or receptacles (such as portable X-ray outlets) do not require ____.
Question 10
Multiple Choice
The branch circuit serving patient bed locations shall ____.
Question 11
Multiple Choice
Receptacles located within the rooms, bathrooms, playrooms, and activity rooms of pediatric units, other than nurseries, shall be listed tamper resistant or shall ____.
Question 12
Multiple Choice
The ____ of the essential electrical system shall supply power for lighting, receptacles, and equipment in a hospital.
Question 13
Multiple Choice
Demand calculations for sizing of the alternate power source(s) for a hospital shall be based on any of the following: (1) prudent demand factors and historical data, (2) ____, (3) Article 220 feeder calculation procedures, or (4) any combination of the preceding.
Question 14
Multiple Choice
Electrical installation criteria and wiring methods for health care facilities are ____ for a standard commercial or industrial project.
Question 15
Multiple Choice
Ground-fault protection of equipment shall be provided for solidly grounded wye electric services of more than 150 volts to ground but not exceeding ____ volts phase-to-phase for each service disconnect rated 1000 amperes or more.