Deck 27: Service-Entrance Equipment

Full screen (f)
exit full mode
Question
What are service lateral conductors?
Use Space or
up arrow
down arrow
to flip the card.
Question
Using an electric rate of $0.07824 per kWh, calculate the cost of running ten 100W lamps for six hours.
Question
A panelboard must not be installed in a(n) ____________________.
Question
If extra support is not to be provided, the mast service conduit must be at least ____ in. in diameter.

A) 1
B) 1-1/2
C) 2
D) 2-1/2
Question
When using a metal water pipe as a grounding electrode, a(n) ____________________ is required.
Question
A main service disconnect shall not be installed in a ____.

A) bedroom
B) laundry room
C) garage
D) bathroom
Question
Under no circumstances shall the service entrance conductors be less than ____ ft. above finished grade.

A) 6
B) 8
C) 10
D) 12
Question
A working space not less than ____ in. wide and 3 ft deep must be provided in front of electrical equipment, such as panelboards A and B in this residence.

A) 16
B) 24
C) 30
D) 36
Question
NEC 300.4(F) states that if ____ AWG or larger ungrounded circuit conductors enter a cabinet, box enclosure or raceway, an insulating bushing or equivalent must be used.

A) 4
B) 6
C) 8
D) 10
Question
____________________ conductors are permitted to be attached to and supported by the service mast.
Question
For a one-family residence, the minimum size main service disconnecting means is ____ three-wire.

A) 30-ampere
B) 60-ampere
C) 100-ampere
D) 150-ampere
Question
A 4 AWG bare copper conductor at least 20 ft (6.0 m) long installed identically to the steel reinforcing rod is also permitted as a concrete-encased grounding electrode. This is often referred to as a(n) ____________________ ground.
Question
For typical residential wiring, the grounding electrode conductor is run between the ____________________ neutral/ground terminal bar and the grounding electrode system.
Question
An exterior raceway containing service entrance conductors must be ____________________ and arranged to drain.
Question
Bonding at service-entrance equipment is very important because service-entrance conductors do not have ____________________ at their line side, other than the electric utility company's primary transformer fuses.
Question
It is extremely important that a disconnect or panelboard used as service equipment be marked "____________________."
Question
NEC ____________________ provides rules for working space around electrical equipment.
Question
Ground clamps used for bonding and grounding must be ____.

A) approved
B) copper
C) steel
D) listed for the purpose
Question
Ground rods must be at least ____ ft. in length

A) 6
B) 8
C) 10
D) 12
Question
What is a service drop?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 27: Service-Entrance Equipment
1
What are service lateral conductors?
If installed by the electric utility, the conductors installed between the pad-mounted transformer and the meter are called service lateral conductors.
2
Using an electric rate of $0.07824 per kWh, calculate the cost of running ten 100W lamps for six hours.
Cost = watts × hours used × cost per kWh/1000
10 lamps at 100W = 1,000W
Cost = watts × hours used × cost per kWh/1000 10 lamps at 100W = 1,000W   46.9¢ 46.9¢
3
A panelboard must not be installed in a(n) ____________________.
bathroom
4
If extra support is not to be provided, the mast service conduit must be at least ____ in. in diameter.

A) 1
B) 1-1/2
C) 2
D) 2-1/2
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
When using a metal water pipe as a grounding electrode, a(n) ____________________ is required.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
A main service disconnect shall not be installed in a ____.

A) bedroom
B) laundry room
C) garage
D) bathroom
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Under no circumstances shall the service entrance conductors be less than ____ ft. above finished grade.

A) 6
B) 8
C) 10
D) 12
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
A working space not less than ____ in. wide and 3 ft deep must be provided in front of electrical equipment, such as panelboards A and B in this residence.

A) 16
B) 24
C) 30
D) 36
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
NEC 300.4(F) states that if ____ AWG or larger ungrounded circuit conductors enter a cabinet, box enclosure or raceway, an insulating bushing or equivalent must be used.

A) 4
B) 6
C) 8
D) 10
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
____________________ conductors are permitted to be attached to and supported by the service mast.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
For a one-family residence, the minimum size main service disconnecting means is ____ three-wire.

A) 30-ampere
B) 60-ampere
C) 100-ampere
D) 150-ampere
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
A 4 AWG bare copper conductor at least 20 ft (6.0 m) long installed identically to the steel reinforcing rod is also permitted as a concrete-encased grounding electrode. This is often referred to as a(n) ____________________ ground.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
For typical residential wiring, the grounding electrode conductor is run between the ____________________ neutral/ground terminal bar and the grounding electrode system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
An exterior raceway containing service entrance conductors must be ____________________ and arranged to drain.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Bonding at service-entrance equipment is very important because service-entrance conductors do not have ____________________ at their line side, other than the electric utility company's primary transformer fuses.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
It is extremely important that a disconnect or panelboard used as service equipment be marked "____________________."
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
NEC ____________________ provides rules for working space around electrical equipment.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Ground clamps used for bonding and grounding must be ____.

A) approved
B) copper
C) steel
D) listed for the purpose
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Ground rods must be at least ____ ft. in length

A) 6
B) 8
C) 10
D) 12
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
What is a service drop?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.