Deck 9: Lighting Branch Circuit for the Master Bedroom

Full screen (f)
exit full mode
Question
Briefly define what is meant by "gangable" boxes.
Use Space or
up arrow
down arrow
to flip the card.
Question
When installing a ceiling paddle fan, the outlet box must be ____.

A) listed and marked as acceptable for fan support
B) metallic
C) secured by four screws
D) all of the above
Question
The outlet box or outlet box system of a ceiling-suspended fans must not support more than ____ pounds must.

A) 25
B) 35
C) 50
D) 70
Question
The suggested fan size for rooms up to 144 square feet is ____________________ inches, and the suggested fan size for rooms up to 500 square feet is ____________________ inches.
Question
A light dimmer ____ be used as a speed control for a ceiling fan or other motor.

A) should
B) should not
Question
Sliding glass panels ____ considered to be wall space, the same as any other interior or exterior door.

A) are
B) are not
Question
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Sliding glass panel
Question
When replacing an existing luminaire (fixture) with a ceiling-suspended paddle fan, make sure that the existing outlet box is listed and marked as ____________________.
Question
Because a homeowner may later decide to install a ceiling fan at any ceiling outlet box serving a lighting fixture, what precaution or provision for the future do many electricians take during original construction?
Question
During the winter, it is suggested that a paddle fan should ____.

A) push air down
B) draw air up
C) not be used
D) only be used on low
Question
A raised plaster cover (often called a plaster ring or mud ring) is permitted to increase the maximum number of conductors permitted in an outlet box when it is ____.

A) listed as a box extension
B) by the same manufacturer as the box
C) marked with its cubic-inch volume
D) metallic and capable of being grounded
Question
The selection of outlet boxes and switch boxes is made by the electrician. These decisions are based on Code requirements, space allowances, good wiring practices, and ____.

A) homeowner's preferences
B) common sense
C) city building codes
D) cost
Question
How can you tell whether a metallic or nonmetallic outlet box is suitable for safely supporting a ceiling fan?
Question
Ceiling fan speed can be controlled by ____.

A) pull chain on the fan
B) speed control mounted in a wall box
C) remote control similar to TV/VCR type
D) any of the above
Question
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed room divider
Question
Some ceiling fan/light units have one lamp socket, whereas others have ____ lamp sockets.

A) four or five
B) six
C) seven
D) eight to ten
Question
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed glass panel
Question
Receptacle outlets must be installed in any wall space ____ or more in width.

A) 12 in. (300 mm)
B) 18 in. (450 mm)
C) 24 in. (600 mm)
D) 36 in. (900 mm)
Question
Which of the following is NOT a reason that ceiling fans must be specially supported?

A) Weight
B) Torque (twisting motion, particularly when first starting)
C) Safe grounding
D) Vibration
Question
Fan speed controllers have internal circuitry that is engineered specifically for use on inductive circuits. Do not use a standard ____________________ to control fan motors.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 9: Lighting Branch Circuit for the Master Bedroom
1
Briefly define what is meant by "gangable" boxes.
Gangable boxes can be combined to form larger boxes by removing their side walls and screwing them together.
2
When installing a ceiling paddle fan, the outlet box must be ____.

A) listed and marked as acceptable for fan support
B) metallic
C) secured by four screws
D) all of the above
A
3
The outlet box or outlet box system of a ceiling-suspended fans must not support more than ____ pounds must.

A) 25
B) 35
C) 50
D) 70
D
4
The suggested fan size for rooms up to 144 square feet is ____________________ inches, and the suggested fan size for rooms up to 500 square feet is ____________________ inches.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
A light dimmer ____ be used as a speed control for a ceiling fan or other motor.

A) should
B) should not
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Sliding glass panels ____ considered to be wall space, the same as any other interior or exterior door.

A) are
B) are not
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Sliding glass panel
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
When replacing an existing luminaire (fixture) with a ceiling-suspended paddle fan, make sure that the existing outlet box is listed and marked as ____________________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Because a homeowner may later decide to install a ceiling fan at any ceiling outlet box serving a lighting fixture, what precaution or provision for the future do many electricians take during original construction?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
During the winter, it is suggested that a paddle fan should ____.

A) push air down
B) draw air up
C) not be used
D) only be used on low
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
A raised plaster cover (often called a plaster ring or mud ring) is permitted to increase the maximum number of conductors permitted in an outlet box when it is ____.

A) listed as a box extension
B) by the same manufacturer as the box
C) marked with its cubic-inch volume
D) metallic and capable of being grounded
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The selection of outlet boxes and switch boxes is made by the electrician. These decisions are based on Code requirements, space allowances, good wiring practices, and ____.

A) homeowner's preferences
B) common sense
C) city building codes
D) cost
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
How can you tell whether a metallic or nonmetallic outlet box is suitable for safely supporting a ceiling fan?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Ceiling fan speed can be controlled by ____.

A) pull chain on the fan
B) speed control mounted in a wall box
C) remote control similar to TV/VCR type
D) any of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed room divider
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Some ceiling fan/light units have one lamp socket, whereas others have ____ lamp sockets.

A) four or five
B) six
C) seven
D) eight to ten
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed glass panel
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Receptacle outlets must be installed in any wall space ____ or more in width.

A) 12 in. (300 mm)
B) 18 in. (450 mm)
C) 24 in. (600 mm)
D) 36 in. (900 mm)
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Which of the following is NOT a reason that ceiling fans must be specially supported?

A) Weight
B) Torque (twisting motion, particularly when first starting)
C) Safe grounding
D) Vibration
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Fan speed controllers have internal circuitry that is engineered specifically for use on inductive circuits. Do not use a standard ____________________ to control fan motors.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.