Deck 4: Panelboards

Full screen (f)
exit full mode
Question
If there is any question as to the exact value of the short-circuit current available at a point, a circuit breaker with interrupt rating is to be installed.

A) no
B) low
C) medium
D) high
Use Space or
up arrow
down arrow
to flip the card.
Question
The voltage ratings of the breakers must be higher than that of the system. Breakers are usually rated at 250 or volts.

A) 300
B) 400
C) 500
D) 600
Question
In general, in a circuit breaker, a low setting may be times the overload rating.

A) two to four
B) six to eight
C) ten to twelve
D) fourteen to sixteen
Question
Two single-pole breakers require installation space that of a double-pole breaker.

A) a quarter
B) one-half
C) equal to
D) double
Question
What should the selection of a circuit breaker be based on?
Question
Panelboards that are not lighting panelboards are known as or distribution panelboards.

A) circuit-breaker
B) power
C) fused
D) feeder
Question
What requirements should be followed for lighting and appliance panelboards?
Question
The main for a panelboard may be either a(n) or a circuit breaker.

A) fuse
B) appliance
C) busbar
D) pole
Question
Briefly discuss panelboard installations that do not require a main protective device and then outline situations in which individual protection is required.
Question
If subfeed lugs are used, the electrician must ensure that the lugs are suitable for making .

A) taps
B) multiple connections
C) one connection
D) lighting boards
Question
When a subfeeder serves more than one panelboard, then connections must be made in the subfeeder for .

A) each panelboard
B) every other panelboard
C) each set of three panelboards
D) each set of four panelboards
Question
The temperature rating of conductors must be selected and coordinated after consideration of the of any connected termination, conductor, or device.

A) lowest temperature rating
B) highest temperature rating
C) current load
D) voltage load
Question
For a three-pole circuit breaker, pole(s) is (are) required for each breaker used.

A) one
B) two
C) three
D) four
Question
Adjustments of the determine the degree of protection provided by the circuit breaker if a short circuit occurs.

A) magnetic trip
B) double pole
C) triple pole
D) overcurrent
Question
The trip rating of the circuit breaker cannot exceed the ampacity of the in the panelboard.

A) fuses
B) appliances
C) switches
D) busbars
Question
Panelboards are available with standard main ratings of 100, 225, 400, 600, 800, and amperes.

A) 900
B) 1000
C) 1100
D) 1200
Question
What rules should be followed to set the magnetic trip?
Question
As a general rule, a panelboard for which more than 10 percent of its overcurrent devices are rated at amperes or less, and for which neutral connections are provided, is defined as a lighting and appliance branch-circuit panelboard.

A) 10
B) 20
C) 30
D) 40
Question
Circuit control and protection must be provided for all circuits and the power-consuming devices connected to these circuits.

A) lighting
B) appliance
C) busway
D) overcurrent
Question
When planning or diagramming a floor-mounted transformer supplying a power panelboard, what are important components to include?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 4: Panelboards
1
If there is any question as to the exact value of the short-circuit current available at a point, a circuit breaker with interrupt rating is to be installed.

A) no
B) low
C) medium
D) high
D
2
The voltage ratings of the breakers must be higher than that of the system. Breakers are usually rated at 250 or volts.

A) 300
B) 400
C) 500
D) 600
D
3
In general, in a circuit breaker, a low setting may be times the overload rating.

A) two to four
B) six to eight
C) ten to twelve
D) fourteen to sixteen
C
4
Two single-pole breakers require installation space that of a double-pole breaker.

A) a quarter
B) one-half
C) equal to
D) double
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
What should the selection of a circuit breaker be based on?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Panelboards that are not lighting panelboards are known as or distribution panelboards.

A) circuit-breaker
B) power
C) fused
D) feeder
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
What requirements should be followed for lighting and appliance panelboards?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
The main for a panelboard may be either a(n) or a circuit breaker.

A) fuse
B) appliance
C) busbar
D) pole
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Briefly discuss panelboard installations that do not require a main protective device and then outline situations in which individual protection is required.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
If subfeed lugs are used, the electrician must ensure that the lugs are suitable for making .

A) taps
B) multiple connections
C) one connection
D) lighting boards
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
When a subfeeder serves more than one panelboard, then connections must be made in the subfeeder for .

A) each panelboard
B) every other panelboard
C) each set of three panelboards
D) each set of four panelboards
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The temperature rating of conductors must be selected and coordinated after consideration of the of any connected termination, conductor, or device.

A) lowest temperature rating
B) highest temperature rating
C) current load
D) voltage load
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
For a three-pole circuit breaker, pole(s) is (are) required for each breaker used.

A) one
B) two
C) three
D) four
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Adjustments of the determine the degree of protection provided by the circuit breaker if a short circuit occurs.

A) magnetic trip
B) double pole
C) triple pole
D) overcurrent
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
The trip rating of the circuit breaker cannot exceed the ampacity of the in the panelboard.

A) fuses
B) appliances
C) switches
D) busbars
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Panelboards are available with standard main ratings of 100, 225, 400, 600, 800, and amperes.

A) 900
B) 1000
C) 1100
D) 1200
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
What rules should be followed to set the magnetic trip?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
As a general rule, a panelboard for which more than 10 percent of its overcurrent devices are rated at amperes or less, and for which neutral connections are provided, is defined as a lighting and appliance branch-circuit panelboard.

A) 10
B) 20
C) 30
D) 40
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Circuit control and protection must be provided for all circuits and the power-consuming devices connected to these circuits.

A) lighting
B) appliance
C) busway
D) overcurrent
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
When planning or diagramming a floor-mounted transformer supplying a power panelboard, what are important components to include?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.