Deck 3: Outlets, Lighting, Appliances, and Heating

Full screen (f)
exit full mode
Question
Even when receptacles are installed outside exposed to weather, it is not necessary to install a cover for them because they are resistant to adverse weather conditions.
Use Space or
up arrow
down arrow
to flip the card.
Question
A conductor that connects to a branch-circuit or feeder conductor to serve a specific load is called a(n) ____________________.
Question
The device that is capable of detecting an arcing condition in a circuit is called a(n) ____________________.
Question
Determine the minimum number of 10-ampere, 120-volt rated general illumination branch-circuits required for an office space of 762m2 in area.Hint: the unit load for this office space is 39 VA/m2.
Question
Electric heating cables are sometimes installed in concrete or poured masonry floors.
Question
Outside of their suitability for use in wet locations, flexible cords with the letter W in the type designation are also ____________________.
Question
The two types of AFCIs are the branch/feeder type and the combination type.
Question
A(n) ____________________ contains two or more circuits that share a common neutral conductor.
Question
Consider that wall spaces in a kitchen are 600 mm or more.What does the end of the kitchen counter require?
Question
Generally, how does one determine if a load is continuous or not?
Question
Porcelain lamp receptacles with bare lamps are a good choice for clothes closets.
Question
Determine the minimum number of general illumination branch-circuits required in a dwelling that is 195 meters square assuming circuits rated at 20 amperes.Hint: according to Table 220.12, the minimum unit load for dwelling general illumination is 33 VA/m2.
Question
The minimum circuit rating for a household electric range is 80 amperes.
Question
The purpose of a(n) ____________________ is to detect a potentially fire-producing arcing condition anywhere in the circuit wiring of the dwelling or in equipment attached to the circuit.
Question
Ground fault equipment protection is required for outdoor snow-melting and de-icing equipment for the purpose of __________________.
Question
How is the minimum number of circuits for general illumination for a dwelling determined?
Question
Which Articles of CODE are used to determine the minimum number of circuits required in a dwelling?
Question
If an appliance has a demand load higher than 60 amperes, then what happens to the load?
Question
A load is considered to be continuous, when the overcurrent device protecting the circuit is loaded to less than or equal to ____________________%.
Question
When comparing electric discharge luminaries to incandescent lamps, the heat produced by incandescent lamps is usually ____________________ (less/greater).
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 3: Outlets, Lighting, Appliances, and Heating
1
Even when receptacles are installed outside exposed to weather, it is not necessary to install a cover for them because they are resistant to adverse weather conditions.
False
2
A conductor that connects to a branch-circuit or feeder conductor to serve a specific load is called a(n) ____________________.
tap
3
The device that is capable of detecting an arcing condition in a circuit is called a(n) ____________________.
arc-fault circuit interrupter
AFCI
arc-fault circuit interrupter (AFCI)
4
Determine the minimum number of 10-ampere, 120-volt rated general illumination branch-circuits required for an office space of 762m2 in area.Hint: the unit load for this office space is 39 VA/m2.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Electric heating cables are sometimes installed in concrete or poured masonry floors.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Outside of their suitability for use in wet locations, flexible cords with the letter W in the type designation are also ____________________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
The two types of AFCIs are the branch/feeder type and the combination type.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
A(n) ____________________ contains two or more circuits that share a common neutral conductor.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Consider that wall spaces in a kitchen are 600 mm or more.What does the end of the kitchen counter require?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Generally, how does one determine if a load is continuous or not?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Porcelain lamp receptacles with bare lamps are a good choice for clothes closets.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Determine the minimum number of general illumination branch-circuits required in a dwelling that is 195 meters square assuming circuits rated at 20 amperes.Hint: according to Table 220.12, the minimum unit load for dwelling general illumination is 33 VA/m2.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The minimum circuit rating for a household electric range is 80 amperes.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
The purpose of a(n) ____________________ is to detect a potentially fire-producing arcing condition anywhere in the circuit wiring of the dwelling or in equipment attached to the circuit.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Ground fault equipment protection is required for outdoor snow-melting and de-icing equipment for the purpose of __________________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
How is the minimum number of circuits for general illumination for a dwelling determined?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Which Articles of CODE are used to determine the minimum number of circuits required in a dwelling?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
If an appliance has a demand load higher than 60 amperes, then what happens to the load?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
A load is considered to be continuous, when the overcurrent device protecting the circuit is loaded to less than or equal to ____________________%.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
When comparing electric discharge luminaries to incandescent lamps, the heat produced by incandescent lamps is usually ____________________ (less/greater).
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.