Deck 14: Float Switches and Liquid Lever Sensors

Full screen (f)
exit full mode
Question
What controls the operation of a float switch?
Use Space or
up arrow
down arrow
to flip the card.
Question
What is a big advantage of the bubbler system?
Question
Float switches are used to control the action of a(n) ____________________ in accordance with the level of a liquid in a tank or sump.
Question
Figure 14-2 Figure 14-2   The accompanying figure shows a rod operated float switch.<div style=padding-top: 35px>
The accompanying figure shows a rod operated float switch.
Question
In the mercury bulb switch, how is the differential level of the liquid determined?
Question
The ____________________ gauge is ideal for measuring the level of turbulent, aerated, solids-laden, viscous, corrosive fluids.
Question
The bubbler system employs the use of float switches.
Question
What is the principle on which the bubbler system operates?
Question
Figure 14-1 Figure 14-1   The accompanying figure shows a(n) ____________________ operated float switch.<div style=padding-top: 35px>
The accompanying figure shows a(n) ____________________ operated float switch.
Question
What is a big advantage of the microwave level gauge?
Question
In the bubbler system, a(n) ____________________ is used to adjust the maximum air flow.
Question
Float switches can be used to pump water from a tank or sump.
Question
In the bubbler system, the pressure required to bubble air through the pipe is directly proportional to the ____________________ of the liquid.
Question
In a mercury bulb switch, when the liquid level is below the position of the bulb, it is suspended in a horizontal position.
Question
The microwave level gauge operates by emitting a high frequency signal of approximately 24 GHz. into a tank and then measuring the frequency difference of the return signal that bounces off the product.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 14: Float Switches and Liquid Lever Sensors
1
What controls the operation of a float switch?
The operation of a float switch is controlled by the upward or downward movement of a float in a tank of liquid.
2
What is a big advantage of the bubbler system?
A great advantage of the bubbler system is that the pressure switches are located outside the tank, which makes it unnecessary to open the tank to service the system.
3
Float switches are used to control the action of a(n) ____________________ in accordance with the level of a liquid in a tank or sump.
pump
4
Figure 14-2 Figure 14-2   The accompanying figure shows a rod operated float switch.
The accompanying figure shows a rod operated float switch.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
In the mercury bulb switch, how is the differential level of the liquid determined?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
The ____________________ gauge is ideal for measuring the level of turbulent, aerated, solids-laden, viscous, corrosive fluids.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
The bubbler system employs the use of float switches.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
What is the principle on which the bubbler system operates?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
Figure 14-1 Figure 14-1   The accompanying figure shows a(n) ____________________ operated float switch.
The accompanying figure shows a(n) ____________________ operated float switch.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
What is a big advantage of the microwave level gauge?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
In the bubbler system, a(n) ____________________ is used to adjust the maximum air flow.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Float switches can be used to pump water from a tank or sump.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
In the bubbler system, the pressure required to bubble air through the pipe is directly proportional to the ____________________ of the liquid.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
In a mercury bulb switch, when the liquid level is below the position of the bulb, it is suspended in a horizontal position.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
The microwave level gauge operates by emitting a high frequency signal of approximately 24 GHz. into a tank and then measuring the frequency difference of the return signal that bounces off the product.