Deck 44: Packaged Units: Electric Air Conditioning and Gas Heat
1
Most door interlock switches are designed so that they are actually a two-position switch.
True
2
Troubleshooting for electronic circuit boards is ____ accomplished only by determining if the board has the proper input information to obtain an output.
A) always
B) generally
C) never
D) sometimes
A) always
B) generally
C) never
D) sometimes
generally
3
A packaged unit schematic typically contains separate references for the air conditioning compressor and condenser fan.
False
4
Lock-out protection involves the use of a ____ that becomes connected in series with the compressor contactor coil in the event of a problem with the compressor circuit.
A) low-pressure relay
B) CC coil
C) LOR coil
D) high-impedance relay
A) low-pressure relay
B) CC coil
C) LOR coil
D) high-impedance relay
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
The compressor lock-out relay can operate only when the thermostat is set in the heating mode.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
In a basic lock-out circuit, the coil of the lock-out relay may be connected in parallel with the normally ____ safety switches used to help protect the compressor.
A) open
B) semi-closed
C) closed
D) semi-open
A) open
B) semi-closed
C) closed
D) semi-open
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
In troubleshooting for electronic circuit boards, if the inputs and outputs are correct, the problem probably lies somewhere within the circuit board.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
The function of the door interlock switch is to permit the unit to operate only when ____.
A) the AGV is energized
B) the furnace door is closed
C) power is applied
D) the unit is in the heating cycle
A) the AGV is energized
B) the furnace door is closed
C) power is applied
D) the unit is in the heating cycle
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
In the cooling cycle of a packaged unit, the indoor blower fan is controlled by the fan switch.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
When the heating thermostat contact closes, a circuit exists to the time delay relay (TDR) and ____.
A) condensing unit
B) door interlock
C) lock-out relay
D) draft motor relay (DMR)
A) condensing unit
B) door interlock
C) lock-out relay
D) draft motor relay (DMR)