Deck 3: Photovoltaic System Examples

Full screen (f)
exit full mode
Question
List inverter system designs.
Use Space or
up arrow
down arrow
to flip the card.
Question
What is a monopole subarray?
Question
Define the term qualified person.
Question
The output of the ac module shall be considered an inverter ____.

A) output cycle
B) source cycle
C) output circuit
D) source circuit
Question
A central inverter system is defined simply as a PV system with a(n) ____.

A) tangential inverter system
B) longitudinal inverter system
C) axial inverter system
D) single inverter system
Question
With an AC module system, we do not calculate the system components as we would do with a standard system.
Question
AC module systems shall be permitted to have a single detection device to detect AC ____ and disconnect the AC power from the module.

A) false cycles
B) high temperatures
C) ground faults
D) high pressures
Question
An array is an assembly of panels or ____ mechanically integrated with a support structure and other components as required (foundation, tracker, etc.) that will form a direct current power producing unit.

A) modules
B) inverters
C) generators
D) oscillators
Question
AFCP devices must detect and interrupt the DC arc faults and then disconnect or disable the inverters or ____ and all the system components in the faulted circuit.

A) polarity controllers
B) charge protectors
C) circuit protectors
D) charge controllers
Question
In an electrical system, fuses are used to protect the wiring and equipment from excessive pressure.
Question
In a string system, if one of the string inverters is out for service, the other inverter(s) will stay on line producing an output.
Question
It is required that each inverter or interconnecting system must have a(n) ____ or circuit breaker.

A) bussman fuse
B) ignition fuse
C) plug fuse
D) dedicated fuse
Question
Every solar panel is a(n) ____.

A) electrical inverter
B) electrical generator
C) electrical cell
D) electrical micro-inverter
Question
How does NEC article 690.2 define an alternating current (AC) module?
Question
In a string inverter system, the inverter should be as close to the array as possible to reduce ____.

A) DC cycles due to temperature
B) DC losses due to voltage drop
C) DC fluctuations due to temperature
D) DC imbalances due to voltage drop
Question
All PV systems are potentially dangerous from an installation and maintenance point of view.
Question
What does the acronym AFCP stand for?
Question
In a string array system, there are a number of ____ in the or on the building of the installation.

A) grid-based tools
B) circle inverters
C) grid-tied inverters
D) square inverters
Question
Any discernible electrical portion of an array can be considered a subpole.
Question
There is a potential danger of combining the circuits of two ____ where the sum of the voltages, without consideration of the polarity, will exceed the rating of the conductor insulation.

A) monopole subarrays
B) counterarrays
C) multipole subarrays
D) multiarrays
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 3: Photovoltaic System Examples
1
List inverter system designs.
These include Micro-Inverter, String Inverter, and Central Inverter designs.
2
What is a monopole subarray?
A monopole subarray is a PV array having an output circuit with two conductors, one negative and one positive.
3
Define the term qualified person.
Qualified person is defined in Article 100 as someone that has skills and knowledge in electrical systems installation and has received safety training.
4
The output of the ac module shall be considered an inverter ____.

A) output cycle
B) source cycle
C) output circuit
D) source circuit
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
A central inverter system is defined simply as a PV system with a(n) ____.

A) tangential inverter system
B) longitudinal inverter system
C) axial inverter system
D) single inverter system
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
With an AC module system, we do not calculate the system components as we would do with a standard system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
AC module systems shall be permitted to have a single detection device to detect AC ____ and disconnect the AC power from the module.

A) false cycles
B) high temperatures
C) ground faults
D) high pressures
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
An array is an assembly of panels or ____ mechanically integrated with a support structure and other components as required (foundation, tracker, etc.) that will form a direct current power producing unit.

A) modules
B) inverters
C) generators
D) oscillators
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
AFCP devices must detect and interrupt the DC arc faults and then disconnect or disable the inverters or ____ and all the system components in the faulted circuit.

A) polarity controllers
B) charge protectors
C) circuit protectors
D) charge controllers
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
In an electrical system, fuses are used to protect the wiring and equipment from excessive pressure.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
In a string system, if one of the string inverters is out for service, the other inverter(s) will stay on line producing an output.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
It is required that each inverter or interconnecting system must have a(n) ____ or circuit breaker.

A) bussman fuse
B) ignition fuse
C) plug fuse
D) dedicated fuse
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
Every solar panel is a(n) ____.

A) electrical inverter
B) electrical generator
C) electrical cell
D) electrical micro-inverter
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
How does NEC article 690.2 define an alternating current (AC) module?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
In a string inverter system, the inverter should be as close to the array as possible to reduce ____.

A) DC cycles due to temperature
B) DC losses due to voltage drop
C) DC fluctuations due to temperature
D) DC imbalances due to voltage drop
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
All PV systems are potentially dangerous from an installation and maintenance point of view.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
What does the acronym AFCP stand for?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
In a string array system, there are a number of ____ in the or on the building of the installation.

A) grid-based tools
B) circle inverters
C) grid-tied inverters
D) square inverters
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Any discernible electrical portion of an array can be considered a subpole.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
There is a potential danger of combining the circuits of two ____ where the sum of the voltages, without consideration of the polarity, will exceed the rating of the conductor insulation.

A) monopole subarrays
B) counterarrays
C) multipole subarrays
D) multiarrays
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.