Deck 12: Raceway Installation
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/47
Play
Full screen (f)
Deck 12: Raceway Installation
1
Section 300.9 states that when installing conduits above grade in a wet location (like outdoors on the side of a house), the interior of the conduit is considered a wet location.
True
2
Type EMT must be supported at least every __________ along the run.(General Rule)
A) 3 feet
B) 5 feet
C) 10 feet
D) 12 feet
A) 3 feet
B) 5 feet
C) 10 feet
D) 12 feet
C
3
To find the maximum number of conductors of the same size and insulation type permitted in various types and sizes of conduit, you would look in __________ of the National Electrical Code.
A) Chapter 8
B) Informative Annex C
C) Informative Annex D
D) the index
A) Chapter 8
B) Informative Annex C
C) Informative Annex D
D) the index
B
4
The securing and supporting requirements for Type FMC are the same as those for Type NM cable.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
5
Nonmetallic sheathed cable is permitted to be installed in a raceway.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
6
Where only two conductors are installed in a raceway, the conduit cannot be filled to more than __________ of the conduit's cross-sectional area according to Table 1 in Chapter 9 of the NEC.
A) 25%
B) 31%
C) 40%
D) 55%
A) 25%
B) 31%
C) 40%
D) 55%
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
7
Although they are not commonly used, threadless couplings and connectors can be used with Type RMC.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
8
Electrical metallic tubing (Type EMT) must be secured within 30 inches of every outlet box, junction box, cabinet, and conduit body.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
9
The NEC considers horizontal runs of Type EMT supported by openings through framing members at intervals not greater than 10' and securely fastened within 3 feet of termination points to be properly supported.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
10
A(n) __________ bend is a conduit bend that is made with two equal-degree bends in such a way so the conduit changes elevation and avoids an obstruction.
A) back-to-back
B) field
C) offset
D) daddle
A) back-to-back
B) field
C) offset
D) daddle
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
11
Rigid metal conduit must be supported at least every __________ feet along a conduit run.(General Rule)
A) 3
B) 8
C) 10
D) 12
A) 3
B) 8
C) 10
D) 12
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
12
The NEC defines Type __________ as an unthreaded thinwall raceway of circular cross section designed for the physical protection and routing of conductors and cables.
A) EMT
B) IMC
C) PVC
D) RMC
A) EMT
B) IMC
C) PVC
D) RMC
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
13
A(n) __________ bend is a conduit bend that results in a conduit going over an object that is blocking the path of the run.
A) back-to-back
B) field
C) offset
D) saddle
A) back-to-back
B) field
C) offset
D) saddle
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
14
Rigid metal conduit must be supported within __________ of outlet boxes, junction boxes, cabinets, and conduit bodies.(General Rule)
A) 8 inches
B) 10 inches
C) 12 inches
D) 36 inches
A) 8 inches
B) 10 inches
C) 12 inches
D) 36 inches
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
15
It is OK to use a metal fish tape to pull or push conductors in a raceway that is connected to an energized loadcenter.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
16
A(n) __________ bend is a conduit bend formed by two 90-degree bends with a straight length of conduit between the two bends.
A) back-to-back
B) field
C) offset
D) saddle
A) back-to-back
B) field
C) offset
D) saddle
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
17
Schedule 80 rigid PVC conduit has a larger inside diameter than Schedule 40 rigid PVC conduit.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
18
The NEC requires that a(n) __________ be used for the protection of conductors sized 4 AWG and larger installed in conduit.
A) antioxidant
B) coupling
C) locknut
D) insulated bushing
A) antioxidant
B) coupling
C) locknut
D) insulated bushing
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
19
A separate equipment grounding conductor must always be installed in runs of Type ENT.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
20
Electricians often refer to Type RMC as "heavy wall" conduit.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
21
__________ is the amount that must be subtracted from a desired stub-up height so the bend will come out right.
A) Sweep
B) Stub height
C) Saddle mark
D) Take-up
A) Sweep
B) Stub height
C) Saddle mark
D) Take-up
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
22
The number of bends in a conduit run from one box to another box cannot exceed a total of ____________________ degrees.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
23
Types RMC, IMC, EMT, and PVC come in standard __________ foot lengths.
A) 5
B) 6
C) 8
D) 10
A) 5
B) 6
C) 8
D) 10
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
24
The metric designator for 6-inch trade-size rigid metal conduit is __________.
A) 100
B) 155
C) 175
D) 208
A) 100
B) 155
C) 175
D) 208
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
25
A steel fish tape should be used when pulling conductors through an installed conduit system and into an energized loadcenter.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
26
Three-point and four-point bends are types of __________ bends.
A) back-to-back
B) offset
C) Saddle
D) None of the above
A) back-to-back
B) offset
C) Saddle
D) None of the above
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
27
When installing more than two conductors in a conduit or tubing, the maximum percentage of fill allowed by the NEC according to Table 1 in Chapter 9 is __________.
A) 25
B) 31
C) 40
D) 60
A) 25
B) 31
C) 40
D) 60
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
28
Type ENT must be supported at intervals not exceeding __________ feet.(General Rule)
A) 10
B) 8
C) 5
D) 3
A) 10
B) 8
C) 5
D) 3
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
29
Any installation of liquidtight flexible metal conduit over ____________________ feet in length requires the installation of an equipment grounding conductor.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
30
The metric designator for 1/2-inch trade-size Type EMT is __________.
A) 12
B) 13
C) 16
D) 28
A) 12
B) 13
C) 16
D) 28
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
31
The most common types of conduit bodies include which of the following?
A) L-shaped bodies ("Ells")
B) T-shaped bodies ("Tees")
C) C-shaped bodies ("Cees")
D) All of the above
A) L-shaped bodies ("Ells")
B) T-shaped bodies ("Tees")
C) C-shaped bodies ("Cees")
D) All of the above
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
32
Conduit systems must be completely installed before the electrical conductors are permitted to be pulled in.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
33
The __________ on a typical conduit hand bender head is where you will place the bending mark when doing the second 90-degree bend of a back-to-back bend.
A) arrow
B) rim notch
C) star point
D) hook
A) arrow
B) rim notch
C) star point
D) hook
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
34
The maximum number of 14 AWG conductors with THHN insulation that you could install in a 3/8-inch trade-size Type FMC is __________ if the connector fittings are inside or __________ if the connector fittings are outside.(Assume the use of a grounding conductor)
A) 1, 2
B) 3, 4
C) 4, 5
D) 5, 6
A) 1, 2
B) 3, 4
C) 4, 5
D) 5, 6
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
35
The __________ on a typical conduit hand bender head is where you will place the bending mark when doing a stub-up bend.
A) arrow
B) rim notch
C) star point
D) hook
A) arrow
B) rim notch
C) star point
D) hook
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
36
The __________ on a typical conduit hand bender head is where you will place the middle bending mark when doing a three-point saddle bend.
A) arrow
B) rim notch
C) star point
D) hook
A) arrow
B) rim notch
C) star point
D) hook
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
37
A(n) __________ plastic cap on the ends of rigid metal conduit designates inch trade sizes.
A) black
B) red
C) blue
D) None of the above
A) black
B) red
C) blue
D) None of the above
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
38
The securing and supporting requirements for liquidtight flexible metal conduit (Type LFMC) are the same as which of the following?
A) Type NM cable
B) Type AC cable
C) Type FMC
D) All of the above
A) Type NM cable
B) Type AC cable
C) Type FMC
D) All of the above
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
39
According to Underwriters Laboratories, lengths of flexible metal conduit longer than __________ have not been judged suitable for equipment grounding purposes.
A) 6 feet
B) 8 feet
C) 10 feet
D) 12 feet
A) 6 feet
B) 8 feet
C) 10 feet
D) 12 feet
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
40
Expansion fittings are generally provided in exposed runs of Type PVC where __________.
A) the run is long
B) the run is subject to large temperature variations during or after installation
C) expansion and contraction measures are provided for the building or other structures
D) All of the above
A) the run is long
B) the run is subject to large temperature variations during or after installation
C) expansion and contraction measures are provided for the building or other structures
D) All of the above
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
41
____________________ is the amount that must be subtracted from a desired stub-up height so the bend will come out right.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
42
The most common conduit bend is a 90-degree bend also known as a(n) ____________________.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
43
The conduit bend used on the conduit ends when the conduit enters a box or other electrical enclosure that is surface mounted is called a(n) _________________________ bend.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
44
Explain the difference between Type FMC and Type AC or Type MC cable.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
45
Describe a conduit body.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
46
Describe the technique that must be used if the length of a conduit run is longer than the length of your longest fish tape.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck
47
Explain the purpose of using cutting oil when threading conduit.
Unlock Deck
Unlock for access to all 47 flashcards in this deck.
Unlock Deck
k this deck