Deck 15: Electrical Services

Full screen (f)
exit full mode
Question
Some fuses are designed to delay for a period of time before they open. These fuses are often referred to as time-delay fuses or ____ fuses.

A) breaker
B) measured-response
C) slow-blow
D) quick-start
Use Space or
up arrow
down arrow
to flip the card.
Question
The type of three-phase service is determined by the type of secondary transformer connection supplied by the power company.
Question
The wire size is determined by the ____ rating of the circuit.

A) voltage
B) ampere
C) reactance
D) turns ratio
Question
When aluminum is used for the bus material, an antioxidant compound should be used to prevent ____.

A) splitting
B) corrosion
C) melting
D) sparking
Question
Standard size circuit breakers are approximately ____ inch(es) in width.

A) 0.5
B) 1
C) 2
D) 4
Question
The fall-of-potential test requires the use of a ground resistance meter.
Question
There are three main tests used to measure ground resistance. One of these is the ____.

A) Wenner five-point test
B) Hall generator test
C) four-point fall-of-potential test
D) clamp-on ground resistance test
Question
When making a 240-V single-phase connection with neutral, the ____ conductors are connected to the poles of the circuit breaker.

A) white and bare
B) black and red
C) black and white
D) red and white
Question
Many circuit breaker panels are designed to employ half-size circuit breakers.
Question
Table 14-2 <strong>Table 14-2   Assume a branch circuit rated at 90 A is to be installed using copper wire with type THW insulation. Use the accompanying table to determine what size conductor should be used for this installation.</strong> A) #2 AWG copper conductor B) #3 AWG copper conductor C) #4 AWG copper conductor D) #6 AWG copper conductor <div style=padding-top: 35px>
Assume a branch circuit rated at 90 A is to be installed using copper wire with type THW insulation. Use the accompanying table to determine what size conductor should be used for this installation.

A) #2 AWG copper conductor
B) #3 AWG copper conductor
C) #4 AWG copper conductor
D) #6 AWG copper conductor
Question
Fuses are connected in series with the load.
Question
The three-phase three-wire system is made by connecting the ____ windings of a three-phase transformer bank in ____ and connecting the three lines to a three-phase panel.

A) secondary; either wye or delta
B) secondary; wye
C) primary; delta
D) primary; wye
Question
Table 14-2 <strong>Table 14-2   A branch circuit rated at 150 A is to be installed using aluminum wire with type THHW insulation. Use the accompanying table to determine what size conductor should be used for this installation.</strong> A) #1/0 AWG conductor B) #2/0 AWG conductor C) #3/0 AWG conductor D) #4/0 AWG conductor <div style=padding-top: 35px>
A branch circuit rated at 150 A is to be installed using aluminum wire with type THHW insulation. Use the accompanying table to determine what size conductor should be used for this installation.

A) #1/0 AWG conductor
B) #2/0 AWG conductor
C) #3/0 AWG conductor
D) #4/0 AWG conductor
Question
Proper grounding helps protect against ____ currents, electrical noise, and lightning strikes.

A) continuous
B) transient
C) transformed
D) closed loop
Question
____-pole circuit breakers are used to connect three-phase circuits.

A) Single
B) Double
C) Three
D) Variable
Question
The clamp-on ground resistance test has several advantages over the three-point fall-of-potential test.
Question
In theory, the system ground is considered to have a resistance of ____.

A) zero
B) one
C) ten
D) infinity
Question
Circuit breakers that operate by heat are known as ____ circuit breakers.

A) fuse
B) magnetic
C) electrical
D) thermal
Question
The three-phase four-wire high-leg connection is made by connecting the secondary windings of a three-phase transformer bank in delta or open delta and center tapping one of the transformer secondaries to provide a(n) ____ conductor.

A) ungrounded
B) bussed
C) neutral
D) hot
Question
In a single-phase service, ____ V is available from the center tap to either end of the secondary winding.

A) 60
B) 100
C) 120
D) 240
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Electrical Services
1
Some fuses are designed to delay for a period of time before they open. These fuses are often referred to as time-delay fuses or ____ fuses.

A) breaker
B) measured-response
C) slow-blow
D) quick-start
C
2
The type of three-phase service is determined by the type of secondary transformer connection supplied by the power company.
True
3
The wire size is determined by the ____ rating of the circuit.

A) voltage
B) ampere
C) reactance
D) turns ratio
B
4
When aluminum is used for the bus material, an antioxidant compound should be used to prevent ____.

A) splitting
B) corrosion
C) melting
D) sparking
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Standard size circuit breakers are approximately ____ inch(es) in width.

A) 0.5
B) 1
C) 2
D) 4
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The fall-of-potential test requires the use of a ground resistance meter.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
There are three main tests used to measure ground resistance. One of these is the ____.

A) Wenner five-point test
B) Hall generator test
C) four-point fall-of-potential test
D) clamp-on ground resistance test
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
When making a 240-V single-phase connection with neutral, the ____ conductors are connected to the poles of the circuit breaker.

A) white and bare
B) black and red
C) black and white
D) red and white
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Many circuit breaker panels are designed to employ half-size circuit breakers.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Table 14-2 <strong>Table 14-2   Assume a branch circuit rated at 90 A is to be installed using copper wire with type THW insulation. Use the accompanying table to determine what size conductor should be used for this installation.</strong> A) #2 AWG copper conductor B) #3 AWG copper conductor C) #4 AWG copper conductor D) #6 AWG copper conductor
Assume a branch circuit rated at 90 A is to be installed using copper wire with type THW insulation. Use the accompanying table to determine what size conductor should be used for this installation.

A) #2 AWG copper conductor
B) #3 AWG copper conductor
C) #4 AWG copper conductor
D) #6 AWG copper conductor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Fuses are connected in series with the load.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The three-phase three-wire system is made by connecting the ____ windings of a three-phase transformer bank in ____ and connecting the three lines to a three-phase panel.

A) secondary; either wye or delta
B) secondary; wye
C) primary; delta
D) primary; wye
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
Table 14-2 <strong>Table 14-2   A branch circuit rated at 150 A is to be installed using aluminum wire with type THHW insulation. Use the accompanying table to determine what size conductor should be used for this installation.</strong> A) #1/0 AWG conductor B) #2/0 AWG conductor C) #3/0 AWG conductor D) #4/0 AWG conductor
A branch circuit rated at 150 A is to be installed using aluminum wire with type THHW insulation. Use the accompanying table to determine what size conductor should be used for this installation.

A) #1/0 AWG conductor
B) #2/0 AWG conductor
C) #3/0 AWG conductor
D) #4/0 AWG conductor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Proper grounding helps protect against ____ currents, electrical noise, and lightning strikes.

A) continuous
B) transient
C) transformed
D) closed loop
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
____-pole circuit breakers are used to connect three-phase circuits.

A) Single
B) Double
C) Three
D) Variable
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The clamp-on ground resistance test has several advantages over the three-point fall-of-potential test.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
In theory, the system ground is considered to have a resistance of ____.

A) zero
B) one
C) ten
D) infinity
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Circuit breakers that operate by heat are known as ____ circuit breakers.

A) fuse
B) magnetic
C) electrical
D) thermal
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
The three-phase four-wire high-leg connection is made by connecting the secondary windings of a three-phase transformer bank in delta or open delta and center tapping one of the transformer secondaries to provide a(n) ____ conductor.

A) ungrounded
B) bussed
C) neutral
D) hot
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
In a single-phase service, ____ V is available from the center tap to either end of the secondary winding.

A) 60
B) 100
C) 120
D) 240
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.