Deck 14: Three-Phase Transformers

Full screen (f)
exit full mode
Question
A true three-phase transformer contains six separate transformers wound on a single core.
Use Space or
up arrow
down arrow
to flip the card.
Question
The amount of magnetic flux produced by one object that influences another is called magnetic ____.

A) coupling
B) induction
C) current
D) balance
Question
When all three lines of a delta-wye connection are carrying the same amount of amperage, what is the neutral current value?

A) zero
B) two
C) four
D) six
Question
Which of the following would most likely be used to show the power distribution system of a large industrial plant?

A) schematic
B) one line diagram
C) cutaway drawing
D) orthographic projection diagram
Question
If the output voltage of a delta secondary is 240 volts, and one winding of the delta connection has been reversed, the voltmeter will indicate a voltage of ____.

A) 214
B) 300
C) 480
D) 577
Question
A three-phase load that has unequal current flow through the phases is said to be ____.

A) volatile
B) neutral
C) positive
D) unbalanced
Question
The disadvantage for three-phase transformers is that if a single transformer should fail, the entire transformer must be repaired or replaced.
Question
What is the output power of an open delta connection?

A) 26.8%
B) 86.6%
C) 100%
D) 125.5%
Question
A voltmeter is a low-impedance device.
Question
As a general rule, three-phase transformers will have one side connected as a ____.

A) neutral
B) wye
C) delta
D) ground
Question
Which of the following is a three-phase connection formed by connecting the start end of a phase winding to the finish end of another?

A) primary
B) wye
C) alpha
D) delta
Question
Which term is used for the voltage measured from the center tap of one transformer in a delta connection to the junction of the transformer(s) that are not center tapped?

A) center tap
B) high leg
C) grounder
D) coupling
Question
A tap in the center of a transformer winding that will provide one half of the rated voltage of the winding is called a ____ tap.

A) secondary
B) balance
C) center
D) primary
Question
Which of the following is a three-phase connection formed by connecting one end of each phase together to form a center point?

A) delta
B) alpha
C) wye
D) series
Question
Three-phase transformer connections are often used to supply single-phase loads, which tend to unbalance the system.
Question
Single-phase transformers connected in three-phase configurations are called three-phase transformer ____.

A) secondaries
B) primaries
C) banks
D) cores
Question
Which of the following is a three-phase transformer connection requiring only two transformers?

A) open wye
B) open delta
C) closed delta
D) closed wye
Question
If power is applied to the transformer bank before the delta connection is closed, the voltmeter should indicate ____ volts.

A) 0
B) 1.12
C) 2.36
D) 4
Question
Delta connections should be checked for proper polarity after applying power.
Question
Checking a delta connection for proper connection is called ____.

A) loading
B) cropping
C) mitigating
D) phasing
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 14: Three-Phase Transformers
1
A true three-phase transformer contains six separate transformers wound on a single core.
False
2
The amount of magnetic flux produced by one object that influences another is called magnetic ____.

A) coupling
B) induction
C) current
D) balance
A
3
When all three lines of a delta-wye connection are carrying the same amount of amperage, what is the neutral current value?

A) zero
B) two
C) four
D) six
A
4
Which of the following would most likely be used to show the power distribution system of a large industrial plant?

A) schematic
B) one line diagram
C) cutaway drawing
D) orthographic projection diagram
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
If the output voltage of a delta secondary is 240 volts, and one winding of the delta connection has been reversed, the voltmeter will indicate a voltage of ____.

A) 214
B) 300
C) 480
D) 577
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
A three-phase load that has unequal current flow through the phases is said to be ____.

A) volatile
B) neutral
C) positive
D) unbalanced
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
The disadvantage for three-phase transformers is that if a single transformer should fail, the entire transformer must be repaired or replaced.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
What is the output power of an open delta connection?

A) 26.8%
B) 86.6%
C) 100%
D) 125.5%
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
A voltmeter is a low-impedance device.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
As a general rule, three-phase transformers will have one side connected as a ____.

A) neutral
B) wye
C) delta
D) ground
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Which of the following is a three-phase connection formed by connecting the start end of a phase winding to the finish end of another?

A) primary
B) wye
C) alpha
D) delta
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Which term is used for the voltage measured from the center tap of one transformer in a delta connection to the junction of the transformer(s) that are not center tapped?

A) center tap
B) high leg
C) grounder
D) coupling
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
A tap in the center of a transformer winding that will provide one half of the rated voltage of the winding is called a ____ tap.

A) secondary
B) balance
C) center
D) primary
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following is a three-phase connection formed by connecting one end of each phase together to form a center point?

A) delta
B) alpha
C) wye
D) series
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Three-phase transformer connections are often used to supply single-phase loads, which tend to unbalance the system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Single-phase transformers connected in three-phase configurations are called three-phase transformer ____.

A) secondaries
B) primaries
C) banks
D) cores
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Which of the following is a three-phase transformer connection requiring only two transformers?

A) open wye
B) open delta
C) closed delta
D) closed wye
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
If power is applied to the transformer bank before the delta connection is closed, the voltmeter should indicate ____ volts.

A) 0
B) 1.12
C) 2.36
D) 4
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Delta connections should be checked for proper polarity after applying power.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Checking a delta connection for proper connection is called ____.

A) loading
B) cropping
C) mitigating
D) phasing
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.