Deck 13: Starting Three-Phase, Squirrel-Cage Induction Motors

Full screen (f)
exit full mode
Question
NEC® requirements regarding starting protection for squirrel-cage induction motors state: The maximum size of fuses permitted to protect motors are rated at 300% of the ____________________ current of the motor for nontime-delay fuses, and 175% for time-delay fuses.
Use Space or
up arrow
down arrow
to flip the card.
Question
Which type of diagram is preferred by many electricians when troubleshooting, and why?
Question
Connecting thermal sensors, called ____________________, are used in an overload monitoring system designed to measure the amount of current flowing to the motor through the contactor.
Question
What are the main components of a magnetic switch used for starting a three-phase AC motor?
Question
Motors can be automatically controlled by using a magnetic starter or may be manually controlled by using a(n) ____________________ type of controller.
Question
Which type of diagram shows physical location as well as general wire routing?
Question
The magnetic switch is called a motor starter if it has overload protection.
Question
____________________ refers to the simplest starting arrangement in which the three-phase AC motor is connected across full line voltage for operation in one direction of rotation.
Question
Referring to the various types of rotor construction and associated code letters, code letter A has high starting torque and relatively low starting current.
Question
If the motor controller is in a higher ambient temperature than the motor it controls, what adjustment should be made by an electrician when choosing the correct heater size?
Question
The National Electrical Code® requires the use of two overload units as running-overload protection Table 430.37.
Question
In addition to the standard contacts, a starter may be provided with externally attached auxiliary contacts, sometimes called ____________________.
Question
In general terms, explain two ways that auxiliary contacts are used.
Question
To reverse the direction of rotation of three-phase motors, interchange any three of the four line lead connections to the motor terminals.
Question
In the case of 125% or 115% overload thermal protection, the Code does allow the electrical personnel to increase the ratings if the original selection does not allow the motor to operate.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Starting Three-Phase, Squirrel-Cage Induction Motors
1
NEC® requirements regarding starting protection for squirrel-cage induction motors state: The maximum size of fuses permitted to protect motors are rated at 300% of the ____________________ current of the motor for nontime-delay fuses, and 175% for time-delay fuses.
full-load
full load
2
Which type of diagram is preferred by many electricians when troubleshooting, and why?
Many electricians find it easier to troubleshoot from a schematic, or elementary, diagram, as it shows the electrical sequence of operation more clearly.
3
Connecting thermal sensors, called ____________________, are used in an overload monitoring system designed to measure the amount of current flowing to the motor through the contactor.
heaters
4
What are the main components of a magnetic switch used for starting a three-phase AC motor?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Motors can be automatically controlled by using a magnetic starter or may be manually controlled by using a(n) ____________________ type of controller.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Which type of diagram shows physical location as well as general wire routing?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
The magnetic switch is called a motor starter if it has overload protection.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
____________________ refers to the simplest starting arrangement in which the three-phase AC motor is connected across full line voltage for operation in one direction of rotation.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
Referring to the various types of rotor construction and associated code letters, code letter A has high starting torque and relatively low starting current.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
If the motor controller is in a higher ambient temperature than the motor it controls, what adjustment should be made by an electrician when choosing the correct heater size?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
The National Electrical Code® requires the use of two overload units as running-overload protection Table 430.37.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
In addition to the standard contacts, a starter may be provided with externally attached auxiliary contacts, sometimes called ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
In general terms, explain two ways that auxiliary contacts are used.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
To reverse the direction of rotation of three-phase motors, interchange any three of the four line lead connections to the motor terminals.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
In the case of 125% or 115% overload thermal protection, the Code does allow the electrical personnel to increase the ratings if the original selection does not allow the motor to operate.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.