1
Dual voltage motors designed for wye-delta starting will supply all 12 T leads at the terminal connection box.
True
2
Dual voltage motors not intended for wye-delta connection will have certain terminals tied internally.
True
3
Open transition starting means that the motor is connected to the power line during the transition from wye to delta.
False
4
What is the most critical part of connecting a wye-delta starter?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Motors that are intended to operate on two voltages such as 240 or 480 volts contain two separate ____________________ of each phase.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
How is wye-delta starting accomplished?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Closed transition starting does not disconnect the motor from the power line.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Figure 26-9

What does the accompanying diagram show?

What does the accompanying diagram show?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
What are the two requirements that must be met before wye-delta starting can be used?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
If the stator windings of a motor are connected in delta during the starting period, the starting current will be ____________________ times the value if the windings were connected in wye.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Figure 26-1

What does the accompanying figure show?

What does the accompanying figure show?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Wye-delta starting is sometimes called ____________________ starting.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
In a wye connection, the line current and phase current are not the same.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Wye-delta starting is often used with large horsepower motors to reduce in-rush current during the starting period and reduce starting ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
If the stator windings are connected in ____________________, the voltage across each phase will be 480 volts because line voltage and phase voltage are the same in a(n) ____________________ connection.