Deck 10: Hydronic Radiant Panel Heating

Full screen (f)
exit full mode
Question
Thermal radiation is constantly emitted from our skin and clothing surfaces to any cooler surfaces around us.
Use Space or
up arrow
down arrow
to flip the card.
Question
Most radiant ceiling panels have low thermal mass allowing them to slowly warm up following a cold start.
Question
Suspended tube systems operate at relatively low water temperatures in comparison to other types of radiant panels.
Question
A hydronic radiant panel is any object warmed by passing heated water through tubing embedded in or attached to it, and which releases at least ____ of that heat to its surroundings as thermal radiation, and has a controlled surface temperature under 300 °F.

A) 80%
B) 60%
C) 50%
D) 40%
Question
In most cases, the system piping method and control technique used are mutually dependent.One cannot be used without the other.
Question
The useful heat output of a radiant panel is expressed as the rate of heat flow into the room per unit of area of radiant panel surface.This is called the room side ____.

A) variance
B) temperature degree
C) heat "sink"
D) heat flux
Question
Another circuit routing pattern for floors is called a ____.This tubing pattern is not designed to bias heat output toward exterior walls.Instead, it is intended to provide the same average heat output over the entire floor area.

A) serpentine
B) zigzag
C) counterflow
D) core
Question
When circuit lengths are significantly different, or when circuits supplied from the same manifold station will operate as separate zones, a(n) ____ manifold station should be used.

A) valveless
B) circuit-balance
C) actuated
D) valved
Question
Gypsum underlayment contains considerably more water than does an equal volume of concrete.
Question
One priciple of tubing design is to install manifold stations in central locations to ____ tubing runs between the manifold station and the room(s) to be heated.

A) straighten
B) minimize
C) maximize
D) economize on
Question
In the case of floor heating, the average surface temperature of the floor should not exceed 85° F in rooms where prolonged foot contact with the floor is likely.
Question
The profiles for baseboard convectors and forced-air systems reveal lower than ideal temperatures near the floor, as well as higher than ideal temperatures near the ceiling.This undesirable effect is called air temperature ____.

A) discharge
B) stratification
C) modulation
D) wastage
Question
The size of the tubing used in a heated slab has a relatively small effect on the slab's heat output.
Question
The availability of insulation in various materials and thicknesses will in part determine the R-value installed.
Question
All hydronic radiant panel systems are created by placing tubing into the ____ of a room.

A) outer perimeter
B) floor, walls, or ceiling
C) areas of thermal loss
D) heat loss zone
Question
The best-known type of hydronic radiant panel is a heated floor.Currently, floors account for over 90% of all hydronic radiant panel installations.
Question
Poured gypsum underlayments have been used for many years to level uneven floor surfaces, as well as to decrease sound transmission and increase the fire resistance of floor assemblies.They are now widely used for ____ radiant floor heating.

A) thin-slab
B) slab-on-grade
C) concrete slab
D) suspended
Question
In some buildings, slab or thin-slab-type radiant panels are not possible.One alternative is called a tube and plate system.Instead of concrete or gypsum, this system uses ____ heat transfer plates to laterally conduct heat away from the tubing.

A) PEX
B) flanged
C) graphite
D) preformed aluminum
Question
Radiant heating is the process of transferring thermal energy from one object to another by ____.

A) convection
B) conduction
C) nuclear radiation
D) thermal radiation
Question
Hydronic radiant panel heating, like other types of hydronic heating, are not easily configured for room-by-room zoning.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 10: Hydronic Radiant Panel Heating
1
Thermal radiation is constantly emitted from our skin and clothing surfaces to any cooler surfaces around us.
True
2
Most radiant ceiling panels have low thermal mass allowing them to slowly warm up following a cold start.
False
3
Suspended tube systems operate at relatively low water temperatures in comparison to other types of radiant panels.
False
4
A hydronic radiant panel is any object warmed by passing heated water through tubing embedded in or attached to it, and which releases at least ____ of that heat to its surroundings as thermal radiation, and has a controlled surface temperature under 300 °F.

A) 80%
B) 60%
C) 50%
D) 40%
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
In most cases, the system piping method and control technique used are mutually dependent.One cannot be used without the other.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The useful heat output of a radiant panel is expressed as the rate of heat flow into the room per unit of area of radiant panel surface.This is called the room side ____.

A) variance
B) temperature degree
C) heat "sink"
D) heat flux
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Another circuit routing pattern for floors is called a ____.This tubing pattern is not designed to bias heat output toward exterior walls.Instead, it is intended to provide the same average heat output over the entire floor area.

A) serpentine
B) zigzag
C) counterflow
D) core
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
When circuit lengths are significantly different, or when circuits supplied from the same manifold station will operate as separate zones, a(n) ____ manifold station should be used.

A) valveless
B) circuit-balance
C) actuated
D) valved
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Gypsum underlayment contains considerably more water than does an equal volume of concrete.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
One priciple of tubing design is to install manifold stations in central locations to ____ tubing runs between the manifold station and the room(s) to be heated.

A) straighten
B) minimize
C) maximize
D) economize on
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
In the case of floor heating, the average surface temperature of the floor should not exceed 85° F in rooms where prolonged foot contact with the floor is likely.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The profiles for baseboard convectors and forced-air systems reveal lower than ideal temperatures near the floor, as well as higher than ideal temperatures near the ceiling.This undesirable effect is called air temperature ____.

A) discharge
B) stratification
C) modulation
D) wastage
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The size of the tubing used in a heated slab has a relatively small effect on the slab's heat output.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
The availability of insulation in various materials and thicknesses will in part determine the R-value installed.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
All hydronic radiant panel systems are created by placing tubing into the ____ of a room.

A) outer perimeter
B) floor, walls, or ceiling
C) areas of thermal loss
D) heat loss zone
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The best-known type of hydronic radiant panel is a heated floor.Currently, floors account for over 90% of all hydronic radiant panel installations.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Poured gypsum underlayments have been used for many years to level uneven floor surfaces, as well as to decrease sound transmission and increase the fire resistance of floor assemblies.They are now widely used for ____ radiant floor heating.

A) thin-slab
B) slab-on-grade
C) concrete slab
D) suspended
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
In some buildings, slab or thin-slab-type radiant panels are not possible.One alternative is called a tube and plate system.Instead of concrete or gypsum, this system uses ____ heat transfer plates to laterally conduct heat away from the tubing.

A) PEX
B) flanged
C) graphite
D) preformed aluminum
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Radiant heating is the process of transferring thermal energy from one object to another by ____.

A) convection
B) conduction
C) nuclear radiation
D) thermal radiation
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Hydronic radiant panel heating, like other types of hydronic heating, are not easily configured for room-by-room zoning.