Deck 22: Installing and Configuring a Usb Driver for 1756-L7 Series Controllers

Full screen (f)
exit full mode
Question
The path displayed in the RSLogix 5000 project Path toolbar is referred to as the ____________________ path.
Use Space or
up arrow
down arrow
to flip the card.
Question
When the gears to the left of the Path toolbar are turning, this signifies that the controller is ____________________.
Question
The initial install of the USB driver on the personal computer is required before using RSLinx to configure the driver.
Question
After clicking + to the left of the USB driver in the RSWho screen, the controller should be displayed in both the right and left panes.
Question
When configuring a driver, verify that RSLinx is current for the version of RSLogix 5000 software being used.
Question
Clicking the ____________________ button in the Who Active window sets the path in the Path toolbar.
Question
One way to configure a new path is to click the network icon on the Language Element toolbar.
Question
RSLogix 5000 software version 20 is the minimum in order to incorporate the 1756-L73 series controllers into a project and configure USB communications.
Question
If a controller icon is not currently displayed in the RSWho screen, this indicates that communications was established at one time, but not in the current session.
Question
A Rockwell Automation 9300-USBS USB to serial adapter is used to communicate between a personal computer with a standard serial port and a programmable automation controller (PAC) with a USB port.
Question
After downloading a RSLogix 5000 project, put the controller in ____________________ mode.
Question
One way to configure the desired communications path is to click Communications from the RSLogix 5000 software Menu Bar and then click ____________________.
Question
If the Go Online, Upload..., and Download buttons are grayed in the Who Active window, this indicates that a valid communications path has yet to be configured.
Question
Before you can upload, download, or go online with a controller, you must verify whether the correct ____________________ path is displayed in the RSLogix 5000 project Path toolbar
Question
The earliest controllers that featured a USB port were the 1756-L6 series controllers.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Installing and Configuring a Usb Driver for 1756-L7 Series Controllers
1
The path displayed in the RSLogix 5000 project Path toolbar is referred to as the ____________________ path.
current
2
When the gears to the left of the Path toolbar are turning, this signifies that the controller is ____________________.
online
3
The initial install of the USB driver on the personal computer is required before using RSLinx to configure the driver.
True
4
After clicking + to the left of the USB driver in the RSWho screen, the controller should be displayed in both the right and left panes.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
When configuring a driver, verify that RSLinx is current for the version of RSLogix 5000 software being used.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Clicking the ____________________ button in the Who Active window sets the path in the Path toolbar.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
One way to configure a new path is to click the network icon on the Language Element toolbar.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
RSLogix 5000 software version 20 is the minimum in order to incorporate the 1756-L73 series controllers into a project and configure USB communications.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
If a controller icon is not currently displayed in the RSWho screen, this indicates that communications was established at one time, but not in the current session.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
A Rockwell Automation 9300-USBS USB to serial adapter is used to communicate between a personal computer with a standard serial port and a programmable automation controller (PAC) with a USB port.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
After downloading a RSLogix 5000 project, put the controller in ____________________ mode.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
One way to configure the desired communications path is to click Communications from the RSLogix 5000 software Menu Bar and then click ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
If the Go Online, Upload..., and Download buttons are grayed in the Who Active window, this indicates that a valid communications path has yet to be configured.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Before you can upload, download, or go online with a controller, you must verify whether the correct ____________________ path is displayed in the RSLogix 5000 project Path toolbar
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
The earliest controllers that featured a USB port were the 1756-L6 series controllers.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.