Deck 24: Configuring 1756 Control Logix Modular Ethernet Hardware

Full screen (f)
exit full mode
Question
The factory default for switches on the top of the 1756-EN2T and 1756-EN2F modules is ____________________, so on power-up, the module will check and see if DHCP or BOOTP is enabled.
Use Space or
up arrow
down arrow
to flip the card.
Question
Ethernet speed is measured as mbps, which stands for ____________________.
Question
When configuring an Ethernet network, the IP addresses in all devices on the network must be ____________________.
Question
Communication with a device on an Ethernet network using Ethernet communications is not possible until an IP address for the device is known or configured.
Question
If using a Series 7 controller or newer CompactLogix controller, the ____________________ port is an easy way to access the current configuration of an Ethernet module.
Question
ControlLogix modular Ethernet communication module comes from the factory configured as ____________________.
Question
The latest generation of Ethernet modules have a(n) ____________________ for temporary connectivity to a personal computer to access, monitor, upload or download, and online edit the RSLogix 5000 project residing in the associated controller.
Question
A network containing the newer IP modules and running at 100 mbps can support the addition of an older 1756-ENET module.
Question
In the term Ethernet/IP, the "IP" stands for Internet Protocol.
Question
The four number groups in an IP address are referred to as octets.
Question
Today the most popular network for new applications for information transferring among computers, controllers, and human interface devices or variable frequency drives is ____________________.
Question
Briefly compare features that distinguish the ENBT module from the ENET module.
Question
Briefly describe the purpose of using the ping command.
Question
The three rotary switches on the top of a 1756-EN2T or 1756-EN2F module can be used to manually configure the IP address for the module.
Question
In many industrial networks, the module's IP address is configured as ____________________, meaning that the IP address of the device will not change.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 24: Configuring 1756 Control Logix Modular Ethernet Hardware
1
The factory default for switches on the top of the 1756-EN2T and 1756-EN2F modules is ____________________, so on power-up, the module will check and see if DHCP or BOOTP is enabled.
999
2
Ethernet speed is measured as mbps, which stands for ____________________.
million bits per second
3
When configuring an Ethernet network, the IP addresses in all devices on the network must be ____________________.
compatible
4
Communication with a device on an Ethernet network using Ethernet communications is not possible until an IP address for the device is known or configured.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
If using a Series 7 controller or newer CompactLogix controller, the ____________________ port is an easy way to access the current configuration of an Ethernet module.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
ControlLogix modular Ethernet communication module comes from the factory configured as ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
The latest generation of Ethernet modules have a(n) ____________________ for temporary connectivity to a personal computer to access, monitor, upload or download, and online edit the RSLogix 5000 project residing in the associated controller.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
A network containing the newer IP modules and running at 100 mbps can support the addition of an older 1756-ENET module.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
In the term Ethernet/IP, the "IP" stands for Internet Protocol.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
The four number groups in an IP address are referred to as octets.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Today the most popular network for new applications for information transferring among computers, controllers, and human interface devices or variable frequency drives is ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Briefly compare features that distinguish the ENBT module from the ENET module.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Briefly describe the purpose of using the ping command.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
The three rotary switches on the top of a 1756-EN2T or 1756-EN2F module can be used to manually configure the IP address for the module.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
In many industrial networks, the module's IP address is configured as ____________________, meaning that the IP address of the device will not change.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.