Deck 5: Understanding Control Logix I-O Addressing

Full screen (f)
exit full mode
Question
In order to operate, every module must have an owner that holds the I/O configuration for the module.
Use Space or
up arrow
down arrow
to flip the card.
Question
The backplane in a ControlLogix chassis is a ControlNet network called "ControlMatrix."
Question
As the chassis modules are configured, they are assigned names. What are two points to keep in mind regarding these names?
Question
If a ControlLogix consists of a single chassis, it is referred to as the ____________________.
Question
Analog module ports are referred to as____________________.
Question
When configuring the I/O for the local chassis, any I/O in a remote chassis that will communicate with the local chassis must also be configured.
Question
Starting with RSLogix 5000 software version ____________________, identification of the controller scoped tags collection changes from the word controller in parentheses to a controller icon displayed to the left of the project name.
Question
Each I/O module is in ____________________ mode until it receives its I/O configuration.
Question
The last piece of the I/O tag string is the bit number with valid entries from 0 to 31.
Question
Briefly compare slot numbering in a ControlLogix modular chassis to slot numbering in a CompactLogix controller.
Question
An analog tag can be an integer, real number, or I/O bit.
Question
Controller scoped tags are global tags. What is meant by the term "global tags?"
Question
What is the format of a typical digital I/O tag?
Question
The specific input tags assigned to an input module depend on the type of input module being configured. Briefly distinguish between tags for standard modules and diagnostic modules.
Question
I/O information is referred to as ____________________.
Question
Communication modules are referred to as ____________________.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/16
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Understanding Control Logix I-O Addressing
1
In order to operate, every module must have an owner that holds the I/O configuration for the module.
True
2
The backplane in a ControlLogix chassis is a ControlNet network called "ControlMatrix."
False
3
As the chassis modules are configured, they are assigned names. What are two points to keep in mind regarding these names?
As the chassis modules are configured, they are assigned a name. The following points apply to these assigned names:
1) Programmers can name modules whatever they wish as long as each name is unique.
2) The module name cannot contain the word "local."
3) The module's name is not used as part of the module's tags.
4
If a ControlLogix consists of a single chassis, it is referred to as the ____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
5
Analog module ports are referred to as____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
6
When configuring the I/O for the local chassis, any I/O in a remote chassis that will communicate with the local chassis must also be configured.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
7
Starting with RSLogix 5000 software version ____________________, identification of the controller scoped tags collection changes from the word controller in parentheses to a controller icon displayed to the left of the project name.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
8
Each I/O module is in ____________________ mode until it receives its I/O configuration.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
9
The last piece of the I/O tag string is the bit number with valid entries from 0 to 31.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
10
Briefly compare slot numbering in a ControlLogix modular chassis to slot numbering in a CompactLogix controller.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
11
An analog tag can be an integer, real number, or I/O bit.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
12
Controller scoped tags are global tags. What is meant by the term "global tags?"
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
13
What is the format of a typical digital I/O tag?
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
14
The specific input tags assigned to an input module depend on the type of input module being configured. Briefly distinguish between tags for standard modules and diagnostic modules.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
15
I/O information is referred to as ____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
16
Communication modules are referred to as ____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 16 flashcards in this deck.