Deck 6: The Control Transformer

Full screen (f)
exit full mode
Question
There is a turns ratio of ____________________ between each primary winding and the secondary winding.
Use Space or
up arrow
down arrow
to flip the card.
Question
When one side of the control transformer is not grounded, it is generally referred to as a(n) ____________________ system.
Question
Control transformers generally have screw terminals connected to the primary and secondary leads.
Question
How do you determine the rated current of a transformer?
Question
Why is it that the secondary fuse size can be set at a lower percentage of the rated current?
Question
Many industries prefer to ground the control system and it is a very common practice.
Question
What is the voltage on which most magnetic control systems operate?
Question
Most control transformers are made with one primary winding and two secondary windings.
Question
High impedance voltmeters can indicate some amount of voltage caused by the capacitance of the ground and induced voltage produced by surrounding magnetic fields. These are generally referred to as ____________________ voltages.
Question
Magnetic control systems generally operate on 240 volts.
Question
Control transformers are generally protected by fuses or ____________________.
Question
When one side of the secondary winding of a control transformer is grounded, the control system is referred to as a(n) ____________________ system.
Question
How is accurate voltage measurement made in a float control system?
Question
How is voltage tested if one side of the control transformer is grounded?
Question
Protection can be placed on the primary or secondary side of the control transformer.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 6: The Control Transformer
1
There is a turns ratio of ____________________ between each primary winding and the secondary winding.
2:1,2 to 1,two to one
2
When one side of the control transformer is not grounded, it is generally referred to as a(n) ____________________ system.
floating
3
Control transformers generally have screw terminals connected to the primary and secondary leads.
True
4
How do you determine the rated current of a transformer?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Why is it that the secondary fuse size can be set at a lower percentage of the rated current?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Many industries prefer to ground the control system and it is a very common practice.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
What is the voltage on which most magnetic control systems operate?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Most control transformers are made with one primary winding and two secondary windings.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
High impedance voltmeters can indicate some amount of voltage caused by the capacitance of the ground and induced voltage produced by surrounding magnetic fields. These are generally referred to as ____________________ voltages.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Magnetic control systems generally operate on 240 volts.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Control transformers are generally protected by fuses or ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
When one side of the secondary winding of a control transformer is grounded, the control system is referred to as a(n) ____________________ system.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
How is accurate voltage measurement made in a float control system?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
How is voltage tested if one side of the control transformer is grounded?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Protection can be placed on the primary or secondary side of the control transformer.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.