Deck 12: Gas Appliances, Regulators, Meters and Appliance Controls

Full screen (f)
exit full mode
Question
Which type of burner does not use any primary air for combustion?

A)absorption
B)injection
C)luminous
D)power
Use Space or
up arrow
down arrow
to flip the card.
Question
If a gas regulator is installed outside, the vent opening should face which direction? Why?
Question
Which of the following results when the blower is arranged to blow air into the combustion chamber?

A)induced draft
B)reduced draft
C)forced draft
D)primary air
Question
Who created the injection burner?

A)Bunsen
B)Benson
C)Einstein
D)Franklin
Question
Which type of burner is most often used for small-fired appliances?

A)absorption
B)injection
C)luminous
D)power
Question
Which type of burner uses a motor-driven blower to deliver primary and secondary air to the combustion zone?

A)absorption
B)injection
C)luminous
D)power
Question
Which of the following meters is  used for smaller loads and lower pressures?

A)rotary
B)displacement
C)placement
D)manual
Question
Absorption units use a mixture of ____________________ and water as refrigerant and require special training and tools to service.
Question
Many standing pilot appliances are being replaced with ____________________ devices because of the growing need for fuel economy and efficiency.
Question
What safety device trips closed when the line pressure exceeds a set value?
Question
Which of the following is defined as a reduction in the primary air intake area that reduces the amount of gas being burned and results in a smaller, soft, and lazy flame?

A)overfiring
B)underfiring
C)spud
D)high efficiency
Question
The principal control device used to achieve lower pressures in gas supply systems is called a(n)____________________.
Question
Which automatic control is a control module capable of monitoring its entire system?

A)thermocouple
B)bimetal disk
C)integrated furnace controller
D)electric pilot igniter
Question
Which of the following meters is used for large volumes and are suitable for any pressure?

A)rotary
B)displacement
C)placement
D)manual
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 12: Gas Appliances, Regulators, Meters and Appliance Controls
1
Which type of burner does not use any primary air for combustion?

A)absorption
B)injection
C)luminous
D)power
C
2
If a gas regulator is installed outside, the vent opening should face which direction? Why?
The vent should face down to prevent rainwater from entering the assembly.
3
Which of the following results when the blower is arranged to blow air into the combustion chamber?

A)induced draft
B)reduced draft
C)forced draft
D)primary air
C
4
Who created the injection burner?

A)Bunsen
B)Benson
C)Einstein
D)Franklin
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
Which type of burner is most often used for small-fired appliances?

A)absorption
B)injection
C)luminous
D)power
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
Which type of burner uses a motor-driven blower to deliver primary and secondary air to the combustion zone?

A)absorption
B)injection
C)luminous
D)power
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following meters is  used for smaller loads and lower pressures?

A)rotary
B)displacement
C)placement
D)manual
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
Absorption units use a mixture of ____________________ and water as refrigerant and require special training and tools to service.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
Many standing pilot appliances are being replaced with ____________________ devices because of the growing need for fuel economy and efficiency.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
What safety device trips closed when the line pressure exceeds a set value?
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
Which of the following is defined as a reduction in the primary air intake area that reduces the amount of gas being burned and results in a smaller, soft, and lazy flame?

A)overfiring
B)underfiring
C)spud
D)high efficiency
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
The principal control device used to achieve lower pressures in gas supply systems is called a(n)____________________.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
Which automatic control is a control module capable of monitoring its entire system?

A)thermocouple
B)bimetal disk
C)integrated furnace controller
D)electric pilot igniter
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following meters is used for large volumes and are suitable for any pressure?

A)rotary
B)displacement
C)placement
D)manual
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 14 flashcards in this deck.