Deck 20: Cross Connections

Full screen (f)
exit full mode
Question
The air gap is the most reliable cross-connection protection.
Use Space or
up arrow
down arrow
to flip the card.
Question
Which of the following backflow protection methods cannot be used on continuous pressure applications?

A)air gap
B)reduced pressure zone backflow preventer
C)atmospheric-type vacuum breaker
D)none of the above
Question
Which backflow prevention method is considered the most efficient and most reliable?

A)air gap
B)double-check valve assembly
C)pressure-type vacuum breaker
D)atmospheric-type vacuum breaker
Question
A contaminated water supply system contains a dangerous substance that is a health hazard.
Question
Give one location where an RPZ backflow preventer should not be installed.
Question
Name the three commonly recognized types of backflow.
Question
Air gaps are typically ____ times the diameter of the supply pipe.

A)1
B)2
C)3
D)4
Question
A polluted system can be referred to as a ____ hazard risk.

A)low
B)medium
C)high
D)toxic
Question
The minimum distance for an air gap is 1 inch.
Question
____ backflow is a reversal of normal flow in a system because downstream pressure is greater than the supply pressure.

A)Back-pressure
B)Gravity
C)Back-siphonage
D)Suction
Question
If a faucet with a ½-inch opening is located 4 inches from an adjacent wall, what is the required air gap distance?

A)1 inch
B)1½ inches
C)2 inches
D)2½ inches
Question
Back-pressure backflow is the same as back-siphonage backflow.
Question
Which of the following backflow prevention methods is approved for all hazards?

A)air gap
B)atmospheric-type vacuum breaker
C)double-check valve assembly
D)pressure-type vacuum breaker
Question
____ occurs when unsafe water flows into the potable water system because the unsafe water is at a higher elevation.

A)Back-pressure backflow
B)Gravity backflow
C)Back-siphonage backflow
D)Capillary backflow
Question
Most dishwashers have a(n)____ as an internal backflow device to protect the potable water supply.

A)air gap
B)reduced pressure zone backflow preventer
C)pressure-type vacuum breaker
D)high loop vacuum breaker
Question
____ backflow is a reversal of normal flow in a system caused by a negative pressure (vacuum)in the potable water supply.

A)Gravity
B)Back-siphonage
C)Back-pressure
D)none of the above
Question
The level of backflow protection required is influenced by the degree of hazard of possible contaminants.
Question
In general, backflow prevention devices should not be installed in pits where flooding could occur.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/18
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 20: Cross Connections
1
The air gap is the most reliable cross-connection protection.
True
2
Which of the following backflow protection methods cannot be used on continuous pressure applications?

A)air gap
B)reduced pressure zone backflow preventer
C)atmospheric-type vacuum breaker
D)none of the above
C
3
Which backflow prevention method is considered the most efficient and most reliable?

A)air gap
B)double-check valve assembly
C)pressure-type vacuum breaker
D)atmospheric-type vacuum breaker
A
4
A contaminated water supply system contains a dangerous substance that is a health hazard.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
5
Give one location where an RPZ backflow preventer should not be installed.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
6
Name the three commonly recognized types of backflow.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
7
Air gaps are typically ____ times the diameter of the supply pipe.

A)1
B)2
C)3
D)4
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
8
A polluted system can be referred to as a ____ hazard risk.

A)low
B)medium
C)high
D)toxic
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
9
The minimum distance for an air gap is 1 inch.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
10
____ backflow is a reversal of normal flow in a system because downstream pressure is greater than the supply pressure.

A)Back-pressure
B)Gravity
C)Back-siphonage
D)Suction
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
11
If a faucet with a ½-inch opening is located 4 inches from an adjacent wall, what is the required air gap distance?

A)1 inch
B)1½ inches
C)2 inches
D)2½ inches
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
12
Back-pressure backflow is the same as back-siphonage backflow.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following backflow prevention methods is approved for all hazards?

A)air gap
B)atmospheric-type vacuum breaker
C)double-check valve assembly
D)pressure-type vacuum breaker
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
14
____ occurs when unsafe water flows into the potable water system because the unsafe water is at a higher elevation.

A)Back-pressure backflow
B)Gravity backflow
C)Back-siphonage backflow
D)Capillary backflow
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
15
Most dishwashers have a(n)____ as an internal backflow device to protect the potable water supply.

A)air gap
B)reduced pressure zone backflow preventer
C)pressure-type vacuum breaker
D)high loop vacuum breaker
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
16
____ backflow is a reversal of normal flow in a system caused by a negative pressure (vacuum)in the potable water supply.

A)Gravity
B)Back-siphonage
C)Back-pressure
D)none of the above
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
17
The level of backflow protection required is influenced by the degree of hazard of possible contaminants.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
18
In general, backflow prevention devices should not be installed in pits where flooding could occur.
Unlock Deck
Unlock for access to all 18 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 18 flashcards in this deck.