Deck 9: Hydronic Heating and Controls

Full screen (f)
exit full mode
Question
Which type of tank operates at atmospheric pressure and is located at highest point of system?

A)compression tank
B)drain tank
C)expansion tank
D)downfeed tank
Use Space or
up arrow
down arrow
to flip the card.
Question
Which of the following is a valve located at the lowest point of the system to provide a drain for the system?

A)drain cock
B)direct return
C)flow fitting
D)flow control valve
Question
A balancing valve is designed to add flow resistance to one circuit in a water system, diverting more flow towards another portion.
Question
Which type of valve consists of a check valve with a fairly heavy closure disk?

A)flow control valve
B)drain cock
C)high limit control valve
D)low-water valve
Question
What is the primary difference between hot water and steam heating systems?

A)hot water systems run at temperatures, pressures above saturation temperature of water
B)hot water systems run at temperatures, pressures below saturation temperature of water
C)boilers feature an open container
D)boilers feature a closed container
Question
What is the purpose of a multiple zone system?

A)creates two different heat temperatures in a boiler
B)permits independent heating in sections of a building
C)allows for multiple boilers to be installed
D)permits both heating and cooling as needed
Question
Which of the following is an example of a terminal unit?

A)convector
B)air vent
C)float
D)seat
Question
Which of the following is installed on a terminal and controls flow through the terminal?

A)relief valve
B)pressure-reducing valve
C)flow control valve
D)radiator valve
Question
When installing forced hot water heating systems, which of the following must happen?

A)minimum operating pressure must be high enough to maintain water at highest terminals
B)air vents should be installed at each terminal and at system high points
C)compression tank should be installed to provide air to minimize pressure variations
D)all of the above
Question
In what situation would natural or gravity circulation most likely be encountered?

A)in ultra-modern buildings
B)in forced circulation systems when pumps are off
C)in forced circulation system when pumps are at full speed
D)none of the above
Question
A downfeed system is a hydronic system with the supply main below the terminals.
Question
Air bound is a condition in which so much air has collected in the system that the flow of water is stopped.
Question
Which of the following uses a liquid-to-air heat exchanger to transfer heat to a space?

A)fan coils
B)aquastat
C)940
D)circuit
Question
Which of the following turns off a burner when the boiler reaches a set temperature?

A)flow fitting
B)high limit control
C)low-water fuel cutoff
D)flow control valve
Question
Modern fan coil unit controls provide what type of benefit?

A)allow control of individual units spread throughout building
B)allow for holistic view of building, with better control
C)allows for computer-controlled temperature management
D)all of the above
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 9: Hydronic Heating and Controls
1
Which type of tank operates at atmospheric pressure and is located at highest point of system?

A)compression tank
B)drain tank
C)expansion tank
D)downfeed tank
C
2
Which of the following is a valve located at the lowest point of the system to provide a drain for the system?

A)drain cock
B)direct return
C)flow fitting
D)flow control valve
A
3
A balancing valve is designed to add flow resistance to one circuit in a water system, diverting more flow towards another portion.
True
4
Which type of valve consists of a check valve with a fairly heavy closure disk?

A)flow control valve
B)drain cock
C)high limit control valve
D)low-water valve
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
What is the primary difference between hot water and steam heating systems?

A)hot water systems run at temperatures, pressures above saturation temperature of water
B)hot water systems run at temperatures, pressures below saturation temperature of water
C)boilers feature an open container
D)boilers feature a closed container
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
What is the purpose of a multiple zone system?

A)creates two different heat temperatures in a boiler
B)permits independent heating in sections of a building
C)allows for multiple boilers to be installed
D)permits both heating and cooling as needed
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following is an example of a terminal unit?

A)convector
B)air vent
C)float
D)seat
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Which of the following is installed on a terminal and controls flow through the terminal?

A)relief valve
B)pressure-reducing valve
C)flow control valve
D)radiator valve
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
When installing forced hot water heating systems, which of the following must happen?

A)minimum operating pressure must be high enough to maintain water at highest terminals
B)air vents should be installed at each terminal and at system high points
C)compression tank should be installed to provide air to minimize pressure variations
D)all of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
In what situation would natural or gravity circulation most likely be encountered?

A)in ultra-modern buildings
B)in forced circulation systems when pumps are off
C)in forced circulation system when pumps are at full speed
D)none of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
A downfeed system is a hydronic system with the supply main below the terminals.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Air bound is a condition in which so much air has collected in the system that the flow of water is stopped.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following uses a liquid-to-air heat exchanger to transfer heat to a space?

A)fan coils
B)aquastat
C)940
D)circuit
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following turns off a burner when the boiler reaches a set temperature?

A)flow fitting
B)high limit control
C)low-water fuel cutoff
D)flow control valve
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Modern fan coil unit controls provide what type of benefit?

A)allow control of individual units spread throughout building
B)allow for holistic view of building, with better control
C)allows for computer-controlled temperature management
D)all of the above
Unlock Deck