Deck 25: Special Refrigeration System Components

Full screen (f)
exit full mode
Question
When a system pumps down, where is the refrigerant stored?

A) Condenser and receiver.
B) Evaporator and compressor.
C) Condenser and compressor.
D) Both a and c.
Use Space or
up arrow
down arrow
to flip the card.
Question
The crankcase pressure regulator (CPR) puts a limit on the pressure that can return to the compressor.
Question
Two-temperature operation of a refrigeration system is necessary when ____.

A) the compressor must be protected from overloading
B) more than one evaporator is used with a compressor
C) the coil in the evaporator is excessively long
D) a multiple-circuit distributor is used
Question
Which of the following is a type of low-ambient temperature head pressure control ?

A) CPR.
B) EPR.
C) Fan cycling.
D) Off-cycle defrost.
Question
EPR valves are also referred to as ____ valves.

A) DRP
B) ORC
C) ORN
D) ORI
Question
Defrost using internal heat is accomplished using ____.

A) a sail switch
B) electric heating elements
C) hot gas from the compressor
D) mullion heaters
Question
To protect the compressor during periods of hot pull down, a(n) ____ valve is used.

A) TXV (thermostatic expansion valve)
B) EPR (evaporator pressure regulator)
C) CPR (crankcase pressure regulator)
D) LAC (low ambient control)
Question
The normal position for a suction service valve during normal operation is ____.

A) back-seated
B) front seated
C) midseated
D) Any of the three.
Question
The EPR valve is installed in the suction line at the evaporator outlet and it ____.

A) modulates the refrigerant vapor to the compressor
B) prevents the boiling point in the evaporator from dropping below a pre-set point
C) when used with a TX valve the system has the characteristics of maintaining a constant superheat and keeping the pressure from going too low
D) All of the above.
Question
Frequently on smaller condensing units, one fan will run continuously and the other fan will be cycled on and off with a(n) ____.

A) ambient temperature controller
B) ambient pressure valve
C) thermal expansion valve
D) thermal control valve
Question
Refrigeration systems are designed to operate year round. For this reason they are equipped with ____.

A) relief valves
B) a low-ambient control
C) oversized evaporator coils
D) EEPR valves
Question
The refrigeration compressor motor can be operated at about ____% over its rated capacity without harm during the pulldown .

A) 5
B) 10
C) 15
D) 20
Question
How does the receiver ensure that only 100% liquid refrigerant enters the liquid line?

A) By means of a dip tube.
B) It only allows refrigerant to enter the liquid line when it is filled with liquid.
C) The spring loaded relief valve opens.
D) None of the above are correct.
Question
Which of the following is another type of low-ambient temperature head pressure control ?

A) Air volume control using shutters and fan cycling.
B) Programmed defrost timer.
C) Timer and liquid line solenoid for automatic pump down.
D) Compressor internal heat.
Question
Oil separators work on the principle of low refrigerant and oil velocity.
Question
____ are snap-acting valves that open and close very fast when the electrical energy is applied to the coil .

A) Contactors
B) Condensers
C) Relays
D) Solenoid valves
Question
Technician "A" says that a multi-evaporator system equipped with three evaporators (one high temperature, one medium temperature, and one low temperature) will use one evaporator pressure regulator and two flow check valves. Technician "B" says that the crankcase pressure regulator is used to keep the low-temperature compressor from overloading on a hot pulldown. Which of the following statements is correct?

A) Technician "A" is correct. Technician "B" is correct.
B) Technician "A" is correct. Technician "B" is incorrect.
C) Technician "A" is incorrect. Technician "B" is correct.
D) Technician "A" is incorrect. Technician "B" is incorrect.
Question
A suction line accumulator is used to ensure that liquid refrigerant enters the compressor.
Question
Random defrost is accomplished ____.

A) with a timer
B) using a high pressure control
C) using a low pressure control
D) when the refrigeration system has enough reserve capacity to cool more than the load requirement
Question
Two-temperature operation is desirable when more than one evaporator is used with a compressor .
Question
Where is the refrigerant filter drier found?
Question
The ____________________ is a mechanical control that keeps the refrigerant pressure in the evaporator from going below a predetermined point.
Question
What is a check valve?
Question
Discuss the king valve .
Question
The spring-loaded type of relief valve is normally brass with a(n) ____________________ seat.
Question
What prevents the oil pressure safety control from de-energizing a compressor immediately after start-up?
Question
List four causes of liquid floodback.
Question
The one-time relief valve is caused to relieve by ____________________.
Question
Automatic pumpdown systems are equipped with a(n) ____________________ to prevent refrigerant from reaching the evaporator .
Question
Where is the refrigerant sight glass normally located?
Question
Helical oil separators are about 58% efficient in separating oil.
Question
What are the two forces that control the EPR valve?
Question
To protect a refrigeration compressor when refrigerant loss occurs, a(n) ____________________ control is used.
Question
What is the temperature range in medium-temperature refrigeration?
Question
Two types of relief valves are the spring-loaded valve and the ____________________ valve .
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/35
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 25: Special Refrigeration System Components
1
When a system pumps down, where is the refrigerant stored?

A) Condenser and receiver.
B) Evaporator and compressor.
C) Condenser and compressor.
D) Both a and c.
A
2
The crankcase pressure regulator (CPR) puts a limit on the pressure that can return to the compressor.
True
3
Two-temperature operation of a refrigeration system is necessary when ____.

A) the compressor must be protected from overloading
B) more than one evaporator is used with a compressor
C) the coil in the evaporator is excessively long
D) a multiple-circuit distributor is used
more than one evaporator is used with a compressor
4
Which of the following is a type of low-ambient temperature head pressure control ?

A) CPR.
B) EPR.
C) Fan cycling.
D) Off-cycle defrost.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
5
EPR valves are also referred to as ____ valves.

A) DRP
B) ORC
C) ORN
D) ORI
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
6
Defrost using internal heat is accomplished using ____.

A) a sail switch
B) electric heating elements
C) hot gas from the compressor
D) mullion heaters
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
7
To protect the compressor during periods of hot pull down, a(n) ____ valve is used.

A) TXV (thermostatic expansion valve)
B) EPR (evaporator pressure regulator)
C) CPR (crankcase pressure regulator)
D) LAC (low ambient control)
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
8
The normal position for a suction service valve during normal operation is ____.

A) back-seated
B) front seated
C) midseated
D) Any of the three.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
9
The EPR valve is installed in the suction line at the evaporator outlet and it ____.

A) modulates the refrigerant vapor to the compressor
B) prevents the boiling point in the evaporator from dropping below a pre-set point
C) when used with a TX valve the system has the characteristics of maintaining a constant superheat and keeping the pressure from going too low
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
10
Frequently on smaller condensing units, one fan will run continuously and the other fan will be cycled on and off with a(n) ____.

A) ambient temperature controller
B) ambient pressure valve
C) thermal expansion valve
D) thermal control valve
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
11
Refrigeration systems are designed to operate year round. For this reason they are equipped with ____.

A) relief valves
B) a low-ambient control
C) oversized evaporator coils
D) EEPR valves
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
12
The refrigeration compressor motor can be operated at about ____% over its rated capacity without harm during the pulldown .

A) 5
B) 10
C) 15
D) 20
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
13
How does the receiver ensure that only 100% liquid refrigerant enters the liquid line?

A) By means of a dip tube.
B) It only allows refrigerant to enter the liquid line when it is filled with liquid.
C) The spring loaded relief valve opens.
D) None of the above are correct.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following is another type of low-ambient temperature head pressure control ?

A) Air volume control using shutters and fan cycling.
B) Programmed defrost timer.
C) Timer and liquid line solenoid for automatic pump down.
D) Compressor internal heat.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
15
Oil separators work on the principle of low refrigerant and oil velocity.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
16
____ are snap-acting valves that open and close very fast when the electrical energy is applied to the coil .

A) Contactors
B) Condensers
C) Relays
D) Solenoid valves
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
17
Technician "A" says that a multi-evaporator system equipped with three evaporators (one high temperature, one medium temperature, and one low temperature) will use one evaporator pressure regulator and two flow check valves. Technician "B" says that the crankcase pressure regulator is used to keep the low-temperature compressor from overloading on a hot pulldown. Which of the following statements is correct?

A) Technician "A" is correct. Technician "B" is correct.
B) Technician "A" is correct. Technician "B" is incorrect.
C) Technician "A" is incorrect. Technician "B" is correct.
D) Technician "A" is incorrect. Technician "B" is incorrect.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
18
A suction line accumulator is used to ensure that liquid refrigerant enters the compressor.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
19
Random defrost is accomplished ____.

A) with a timer
B) using a high pressure control
C) using a low pressure control
D) when the refrigeration system has enough reserve capacity to cool more than the load requirement
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
20
Two-temperature operation is desirable when more than one evaporator is used with a compressor .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
21
Where is the refrigerant filter drier found?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
22
The ____________________ is a mechanical control that keeps the refrigerant pressure in the evaporator from going below a predetermined point.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
23
What is a check valve?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
24
Discuss the king valve .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
25
The spring-loaded type of relief valve is normally brass with a(n) ____________________ seat.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
26
What prevents the oil pressure safety control from de-energizing a compressor immediately after start-up?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
27
List four causes of liquid floodback.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
28
The one-time relief valve is caused to relieve by ____________________.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
29
Automatic pumpdown systems are equipped with a(n) ____________________ to prevent refrigerant from reaching the evaporator .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
30
Where is the refrigerant sight glass normally located?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
31
Helical oil separators are about 58% efficient in separating oil.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
32
What are the two forces that control the EPR valve?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
33
To protect a refrigeration compressor when refrigerant loss occurs, a(n) ____________________ control is used.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
34
What is the temperature range in medium-temperature refrigeration?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
35
Two types of relief valves are the spring-loaded valve and the ____________________ valve .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 35 flashcards in this deck.