The cad cell relay is a safety device that uses which of the following to prove ignition ?

A) Heat in the flue.
B) Heat in the combustion chamber.
C) Light in the combustion chamber.
D) Heat in the blast tube.
Use Space or
up arrow
down arrow
to flip the card.
Question
If a technician inspects the interior of a combustion chamber and finds large quantities of unburned oil, he would correctly conclude that the ____ .

A) nozzle may be too small
B) stack switch or cad cell may be defective
C) primary control unit may be defective
D) Both b and c are correct.
Question
To make combustion efficiency tests, a hole must be made ____.

A) in the flue pipe after the draft control
B) in the flue pipe before the draft control
C) over the fire at the observation door
D) under the draft hood
Question
Tank piping should be inspected regularly for imperfections and leaks.
Question
An auxiliary tank and booster pump system is required if the oil supply is situated ____ below the oil burner pump .

A) any distance
B) 5 feet or more
C) 10 feet or more
D) 15 feet or more
Question
The grade of fuel used in residential and light commercial units is ____.

A) Number 1
B) Number 2
C) Number 4
D) Number 6
Question
Tanks that are to be installed underground must be protected against corrosion.
Question
Nozzles can be cleaned to remove any carbonization by using a very fine wire brush.
Question
Improper combustion can lead to ____.

A) excessive carbon monoxide production
B) smoke condition around furnace
C) wasted fuel oil
D) All of the above.
Question
The heat content of one gallon of No. 2 fuel oil is about ____________________ Btu.
Question
In a(n) ____________________ fuel oil supply system, one pipe is the supply and the other acts as the return .
Question
In a single-stage fuel oil pump, the oil is fed to the burner by capillary action.
Question
A condensing oil furnace operates at a higher efficiency because part of the heat output is ____.

A) sensible heat
B) latent heat
C) superheat
D) sub-cooling
Question
When nozzles problems are apparent, the nozzle should be removed using ____ and replaced .

A) a special nozzle wrench
B) adjustable pliers
C) a pipe wrench
D) Both a and b.
Question
____________________ is the amount of carbon left in a sample of oil after it is changed from a liquid to a vapor by being boiled in an oxygen-free atmosphere .
Question
When any product containing hydrogen and/or carbon reacts with oxygen to release heat energy, the process is called ____________________.
Question
The stack switch or stack relay ____.

A) starts the fan motor when the thermostat calls for heat
B) shuts down the burner if it does not sense heat in the stack
C) cuts off the ignition after the flame has been established
D) All of the above.
Question
Oil burner nozzles are rated at 100 psig nozzle pressure .
Question
Oil tanks should be checked for water at least once a month .
Question
When the oil tank is above the oil burner pump, the fuel oil supply system would normally be a ____.

A) gravity flow, one-pipe system
B) single-stage pump, two-pipe system
C) two-stage pump, one-pipe system
D) two-stage pump, two-pipe system
Question
Match between columns
Changes its resistance depending on the amount of light it senses
nozzle
Changes its resistance depending on the amount of light it senses
ignition transformer
Changes its resistance depending on the amount of light it senses
stack switch
Changes its resistance depending on the amount of light it senses
flame retention burner
Changes its resistance depending on the amount of light it senses
cad cell
Changes its resistance depending on the amount of light it senses
electrodes
Creates efficient tighter and more uniform flame
nozzle
Creates efficient tighter and more uniform flame
ignition transformer
Creates efficient tighter and more uniform flame
stack switch
Creates efficient tighter and more uniform flame
flame retention burner
Creates efficient tighter and more uniform flame
cad cell
Creates efficient tighter and more uniform flame
electrodes
Insulated with ceramic material to prevent electrical ground
nozzle
Insulated with ceramic material to prevent electrical ground
ignition transformer
Insulated with ceramic material to prevent electrical ground
stack switch
Insulated with ceramic material to prevent electrical ground
flame retention burner
Insulated with ceramic material to prevent electrical ground
cad cell
Insulated with ceramic material to prevent electrical ground
electrodes
Generates over 10,000 volts needed for spark
nozzle
Generates over 10,000 volts needed for spark
ignition transformer
Generates over 10,000 volts needed for spark
stack switch
Generates over 10,000 volts needed for spark
flame retention burner
Generates over 10,000 volts needed for spark
cad cell
Generates over 10,000 volts needed for spark
electrodes
Meters flow of fuel oil into the chamber
nozzle
Meters flow of fuel oil into the chamber
ignition transformer
Meters flow of fuel oil into the chamber
stack switch
Meters flow of fuel oil into the chamber
flame retention burner
Meters flow of fuel oil into the chamber
cad cell
Meters flow of fuel oil into the chamber
electrodes
B imetal-actuated device that will shut burner down in case the burner doesn't fire
nozzle
B imetal-actuated device that will shut burner down in case the burner doesn't fire
ignition transformer
B imetal-actuated device that will shut burner down in case the burner doesn't fire
stack switch
B imetal-actuated device that will shut burner down in case the burner doesn't fire
flame retention burner
B imetal-actuated device that will shut burner down in case the burner doesn't fire
cad cell
B imetal-actuated device that will shut burner down in case the burner doesn't fire
electrodes
Question
There are two main types of oil pumps used on gun-type burners, single-stage and ____________________ pumps .
Question
How can a technician tell the difference between an upflow furnace and a downflow furnace?
Question
Carbon monoxide is a(n) ____________________ and odorless gas .
Question
The portion of a nozzle assembly that produces rotation of the oil spray is called the ____________________  .
Question
Fill and ____________________ pipes should be pitched toward the tank opening to prevent the formation of oil traps .
Question
What tests can a technician perform on an oil furnace that will check the combustion efficiency?
Question
Fuel pumps are equipped with ____________________ at the inlet to prevent particulate matter from entering the pump.
Question
Oil lines are typically made of copper and should be sized at a minimum ____________________ OD .
Question
Name six parts of an oil burner nozzle .
Question
The ____________________ is an oil piping component that allows a one-pipe system to function as a two-pipe system .
Question
If an oil burner equipped with the cad cell relay ignites, runs for about ninety seconds, and cuts off. What is the first thing the service technician should do ?
Question
Define atomization.
Question
Modern oil burners are referred as high pressure burners, as the oil is delivered through the burner at a pressure of minimum ____________________ psi .
Question
The process of breaking up a liquid into fine droplets is called ____________________ .
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/35
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 32: Oil Heat
1
The cad cell relay is a safety device that uses which of the following to prove ignition ?

A) Heat in the flue.
B) Heat in the combustion chamber.
C) Light in the combustion chamber.
D) Heat in the blast tube.
C
2
If a technician inspects the interior of a combustion chamber and finds large quantities of unburned oil, he would correctly conclude that the ____ .

A) nozzle may be too small
B) stack switch or cad cell may be defective
C) primary control unit may be defective
D) Both b and c are correct.
D
3
To make combustion efficiency tests, a hole must be made ____.

A) in the flue pipe after the draft control
B) in the flue pipe before the draft control
C) over the fire at the observation door
D) under the draft hood
B
4
Tank piping should be inspected regularly for imperfections and leaks.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
5
An auxiliary tank and booster pump system is required if the oil supply is situated ____ below the oil burner pump .

A) any distance
B) 5 feet or more
C) 10 feet or more
D) 15 feet or more
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
6
The grade of fuel used in residential and light commercial units is ____.

A) Number 1
B) Number 2
C) Number 4
D) Number 6
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
7
Tanks that are to be installed underground must be protected against corrosion.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
8
Nozzles can be cleaned to remove any carbonization by using a very fine wire brush.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
9
Improper combustion can lead to ____.

A) excessive carbon monoxide production
B) smoke condition around furnace
C) wasted fuel oil
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
10
The heat content of one gallon of No. 2 fuel oil is about ____________________ Btu.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
11
In a(n) ____________________ fuel oil supply system, one pipe is the supply and the other acts as the return .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
12
In a single-stage fuel oil pump, the oil is fed to the burner by capillary action.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
13
A condensing oil furnace operates at a higher efficiency because part of the heat output is ____.

A) sensible heat
B) latent heat
C) superheat
D) sub-cooling
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
14
When nozzles problems are apparent, the nozzle should be removed using ____ and replaced .

A) a special nozzle wrench
B) adjustable pliers
C) a pipe wrench
D) Both a and b.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
15
____________________ is the amount of carbon left in a sample of oil after it is changed from a liquid to a vapor by being boiled in an oxygen-free atmosphere .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
16
When any product containing hydrogen and/or carbon reacts with oxygen to release heat energy, the process is called ____________________.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
17
The stack switch or stack relay ____.

A) starts the fan motor when the thermostat calls for heat
B) shuts down the burner if it does not sense heat in the stack
C) cuts off the ignition after the flame has been established
D) All of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
18
Oil burner nozzles are rated at 100 psig nozzle pressure .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
19
Oil tanks should be checked for water at least once a month .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
20
When the oil tank is above the oil burner pump, the fuel oil supply system would normally be a ____.

A) gravity flow, one-pipe system
B) single-stage pump, two-pipe system
C) two-stage pump, one-pipe system
D) two-stage pump, two-pipe system
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
21
Match between columns
Changes its resistance depending on the amount of light it senses
nozzle
Changes its resistance depending on the amount of light it senses
ignition transformer
Changes its resistance depending on the amount of light it senses
stack switch
Changes its resistance depending on the amount of light it senses
flame retention burner
Changes its resistance depending on the amount of light it senses
cad cell
Changes its resistance depending on the amount of light it senses
electrodes
Creates efficient tighter and more uniform flame
nozzle
Creates efficient tighter and more uniform flame
ignition transformer
Creates efficient tighter and more uniform flame
stack switch
Creates efficient tighter and more uniform flame
flame retention burner
Creates efficient tighter and more uniform flame
cad cell
Creates efficient tighter and more uniform flame
electrodes
Insulated with ceramic material to prevent electrical ground
nozzle
Insulated with ceramic material to prevent electrical ground
ignition transformer
Insulated with ceramic material to prevent electrical ground
stack switch
Insulated with ceramic material to prevent electrical ground
flame retention burner
Insulated with ceramic material to prevent electrical ground
cad cell
Insulated with ceramic material to prevent electrical ground
electrodes
Generates over 10,000 volts needed for spark
nozzle
Generates over 10,000 volts needed for spark
ignition transformer
Generates over 10,000 volts needed for spark
stack switch
Generates over 10,000 volts needed for spark
flame retention burner
Generates over 10,000 volts needed for spark
cad cell
Generates over 10,000 volts needed for spark
electrodes
Meters flow of fuel oil into the chamber
nozzle
Meters flow of fuel oil into the chamber
ignition transformer
Meters flow of fuel oil into the chamber
stack switch
Meters flow of fuel oil into the chamber
flame retention burner
Meters flow of fuel oil into the chamber
cad cell
Meters flow of fuel oil into the chamber
electrodes
B imetal-actuated device that will shut burner down in case the burner doesn't fire
nozzle
B imetal-actuated device that will shut burner down in case the burner doesn't fire
ignition transformer
B imetal-actuated device that will shut burner down in case the burner doesn't fire
stack switch
B imetal-actuated device that will shut burner down in case the burner doesn't fire
flame retention burner
B imetal-actuated device that will shut burner down in case the burner doesn't fire
cad cell
B imetal-actuated device that will shut burner down in case the burner doesn't fire
electrodes
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
22
There are two main types of oil pumps used on gun-type burners, single-stage and ____________________ pumps .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
23
How can a technician tell the difference between an upflow furnace and a downflow furnace?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
24
Carbon monoxide is a(n) ____________________ and odorless gas .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
25
The portion of a nozzle assembly that produces rotation of the oil spray is called the ____________________  .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
26
Fill and ____________________ pipes should be pitched toward the tank opening to prevent the formation of oil traps .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
27
What tests can a technician perform on an oil furnace that will check the combustion efficiency?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
28
Fuel pumps are equipped with ____________________ at the inlet to prevent particulate matter from entering the pump.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
29
Oil lines are typically made of copper and should be sized at a minimum ____________________ OD .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
30
Name six parts of an oil burner nozzle .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
31
The ____________________ is an oil piping component that allows a one-pipe system to function as a two-pipe system .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
32
If an oil burner equipped with the cad cell relay ignites, runs for about ninety seconds, and cuts off. What is the first thing the service technician should do ?
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
33
Define atomization.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
34
Modern oil burners are referred as high pressure burners, as the oil is delivered through the burner at a pressure of minimum ____________________ psi .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
35
The process of breaking up a liquid into fine droplets is called ____________________ .
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 35 flashcards in this deck.