Deck 40: Typical Operating Conditions

Full screen (f)
exit full mode
Question
The larger the EER rating, the less efficient the equipment.
Use Space or
up arrow
down arrow
to flip the card.
Question
A 4-ton air-conditioning system that requires an input power of 5 kW would have an energy efficiency ratio of ____________________.
Question
Most occupants will normally operate their system at about ____°F.

A) 68
B) 72
C) 75
D) 80
Question
For residential air-conditioning units, ____________________ V single-phase is the typical voltage.
Question
At typical operating conditions, the high efficiency air-conditioning system will operate with an evaporator boiling point of ____°F.

A) 40
B) 45
C) 50
D) 55
Question
Ratings that are not completely accurate are known as ____.

A) load ratings
B) maximal ratings
C) nominal ratings
D) floor ratings
Question
The condenser ____________________ heat.
Question
A four-pole motor runs at ____________________ rpm.
Question
The evaporator ____________________ heat.
Question
Since the evaporator absorbs both sensible and latent heat, humidity must be taken into account and considered part of the load on the evaporator.
Question
AHRI rates condensers with ____°F air passing over them.

A) 70
B) 75
C) 85
D) 95
Question
Typically, the fan will run on high speed when the outdoor temperature is above ____________________°F.
Question
High efficiency condensers can actually be too efficient on cool days.
Question
A more accurate rating system for air-conditioning equipment that takes into consideration operation during the complete cycle is the ____ standard.

A) ARI
B) ACCA
C) SEER
D) EER
Question
At typical operating conditions, the standard air-conditioning system will operate with an evaporator boiling point of ____°F.

A) 40
B) 45
C) 50
D) 55
Question
A normal evaporator superheat at the evaporator outlet in a standard efficiency air-conditioning system operating under design conditions will be ____°F.

A) 10
B) 15
C) 20
D) 25
Question
Air-conditioning systems normally move about ____________________ cfm of air per ton.
Question
At what conditions are air-conditioning systems rated?

A) 95°F outdoors - 70°F DB - 50% indoors
B) 95°F outdoors - 75°F DB - 50% indoors
C) 95°F outdoors - 80°F DB - 50% indoors
D) 100°F outdoors - 80°F DB - 60% indoors
Question
The electrical operating conditions are measured with a voltohmmeter and a(n) ____________________ .
Question
The ____ rating is a steady-state rating and does not account for the time the unit operates before reaching peak efficiency.

A) ARR
B) SAR
C) DER
D) EER
Question
Why does the high efficiency system have a higher operating efficiency?
Question
What are the three major power-consuming devices that may have to be analyzed from time to time on an air-conditioning unit?
Question
Why does high-efficiency air-conditioning equipment use a thermostatic expansion valve?
Question
What are three things that must be considered when the manufacturer publishes typical operating conditions?
Question
What is starting point for considering electrical operating conditions?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 40: Typical Operating Conditions
1
The larger the EER rating, the less efficient the equipment.
False
2
A 4-ton air-conditioning system that requires an input power of 5 kW would have an energy efficiency ratio of ____________________.
9.6
3
Most occupants will normally operate their system at about ____°F.

A) 68
B) 72
C) 75
D) 80
C
4
For residential air-conditioning units, ____________________ V single-phase is the typical voltage.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
At typical operating conditions, the high efficiency air-conditioning system will operate with an evaporator boiling point of ____°F.

A) 40
B) 45
C) 50
D) 55
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Ratings that are not completely accurate are known as ____.

A) load ratings
B) maximal ratings
C) nominal ratings
D) floor ratings
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
The condenser ____________________ heat.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
A four-pole motor runs at ____________________ rpm.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
The evaporator ____________________ heat.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Since the evaporator absorbs both sensible and latent heat, humidity must be taken into account and considered part of the load on the evaporator.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
AHRI rates condensers with ____°F air passing over them.

A) 70
B) 75
C) 85
D) 95
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Typically, the fan will run on high speed when the outdoor temperature is above ____________________°F.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
High efficiency condensers can actually be too efficient on cool days.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
A more accurate rating system for air-conditioning equipment that takes into consideration operation during the complete cycle is the ____ standard.

A) ARI
B) ACCA
C) SEER
D) EER
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
At typical operating conditions, the standard air-conditioning system will operate with an evaporator boiling point of ____°F.

A) 40
B) 45
C) 50
D) 55
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
A normal evaporator superheat at the evaporator outlet in a standard efficiency air-conditioning system operating under design conditions will be ____°F.

A) 10
B) 15
C) 20
D) 25
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Air-conditioning systems normally move about ____________________ cfm of air per ton.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
At what conditions are air-conditioning systems rated?

A) 95°F outdoors - 70°F DB - 50% indoors
B) 95°F outdoors - 75°F DB - 50% indoors
C) 95°F outdoors - 80°F DB - 50% indoors
D) 100°F outdoors - 80°F DB - 60% indoors
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
The electrical operating conditions are measured with a voltohmmeter and a(n) ____________________ .
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
The ____ rating is a steady-state rating and does not account for the time the unit operates before reaching peak efficiency.

A) ARR
B) SAR
C) DER
D) EER
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Why does the high efficiency system have a higher operating efficiency?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
What are the three major power-consuming devices that may have to be analyzed from time to time on an air-conditioning unit?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Why does high-efficiency air-conditioning equipment use a thermostatic expansion valve?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
What are three things that must be considered when the manufacturer publishes typical operating conditions?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
What is starting point for considering electrical operating conditions?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.