Deck 41: Troubleshooting
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Match between columns
Premises:
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
improper system balancing
improper system balancing
improper system balancing
improper system balancing
improper system balancing
improper system balancing
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
Responses:
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/28
Play
Full screen (f)
Deck 41: Troubleshooting
1
The liquid line temperature is used to determine the ____ of a condenser.
A) superheat
B) lowside pressure
C) suction pressure
D) subcooling
A) superheat
B) lowside pressure
C) suction pressure
D) subcooling
D
2
With a rise in outdoor temperature, the head pressure will rise.
True
3
The instrument to use to check for a short in the compressor motor winding is a(n) ____.
A) ohmmeter
B) ammeter
C) voltmeter
D) milliammeter
A) ohmmeter
B) ammeter
C) voltmeter
D) milliammeter
A
4
A service valve can be used to ____.
A) check the electrical service to the compressor
B) isolate the refrigerant so the system can be serviced
C) check the air flow across the evaporator
D) check the ambient temperature at the condenser
A) check the electrical service to the compressor
B) isolate the refrigerant so the system can be serviced
C) check the air flow across the evaporator
D) check the ambient temperature at the condenser
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
5
As a rule of thumb, the air leaving the evaporator will be about ____ than the air entering the evaporator.
A) 10-15° warmer
B) 10-15° cooler
C) 17-20° cooler
D) 17-20° warmer
A) 10-15° warmer
B) 10-15° cooler
C) 17-20° cooler
D) 17-20° warmer
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
6
Reducing the CFM through the evaporator will cause the amperage draw of the compressor to ____________________.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
7
The best way to tell if a compressor's discharge line is at the correct temperature is to grab hold of it.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
8
Why do we measure temperatures at the evaporator rather than the suction pressure?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
9
On a 95°F day, the R-22 refrigerant pressure on the high side should be about ____ psig.
A) 108
B) 182
C) 243
D) 297
A) 108
B) 182
C) 243
D) 297
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
10
On most gauge manifolds, the suction or low side gauge is located on the ____________________.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
11
Temperature difference is used to describe the difference in the inlet and _________ temperature of a heat exchanger.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
12
Reducing the CFM through the evaporator will cause the head pressure to ____________________.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
13
If a compressor has a partially shorted winding, it could run for a while, overheat, and shut off.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
14
Why should a technician visually inspect the equipment before installing gauges?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
15
When checking the electrical circuits of an air-conditioning system, each parallel circuit should be isolated and checked separately.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
16
Two types of fixed-bore metering devices are capillary tubes and _________________________.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
17
A typical evaporator superheat reading at the evaporator outlet for a central air-conditioning system on a 95°F day would be ____°F.
A) 5-7
B) 8-10
C) 10-12
D) 12-15
A) 5-7
B) 8-10
C) 10-12
D) 12-15
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
18
Subcooling occurs in the evaporator as well as the condenser.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
19
To accurately add refrigerant to a system, a condenser ambient temperature of ____°F should be simulated.
A) 75
B) 85
C) 95
D) 100
A) 75
B) 85
C) 95
D) 100
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
20
Superheat occurs in the condenser as well as the evaporator.
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
21
Match between columns
Premises:
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
refrigerant undercharge
improper system balancing
improper system balancing
improper system balancing
improper system balancing
improper system balancing
improper system balancing
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
refrigerant overcharge
Responses:
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
high operating pressures
frozen evaporator coil
low superheat
high superheat
low operating pressures
uneven cooling
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
22
What is the process that normally begins the electrical troubleshooting of the system?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
23
How would too much refrigerant affect the operation of a system with capillary tubes?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
24
While passing through the condenser, refrigerant is in three different states. What are they?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
25
When is it necessary to connect gauges onto a system?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
26
Why is the head pressure raised to 278 psig to check the subcooling of the system?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
27
Where is the correct location for a sight glass in order to check the charge?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck
28
If a technician finds the circuit protection for an air-conditioning component has been tripped, what should the technician do?
Unlock Deck
Unlock for access to all 28 flashcards in this deck.
Unlock Deck
k this deck