Deck 9: Gas Piping, Venting, and Appliance Efficiency

Full screen (f)
exit full mode
Question
If there is too much primary air, the gas flame can ____.

A) get blown out
B) "lift" off the burner rack
C) make noise
D) both b and c
Use Space or
up arrow
down arrow
to flip the card.
Question
What is the difference between a yellow gas flame and an orange gas flame?
Question
When a gas furnace ignites and is under "full-fire," why does the fan not come on immediately?
Question
In a conventional gas furnace, the hot flue gases are ____.

A) forced out a PVC vent with a blower
B) recycled through a secondary heat exchanger and then vented through a draft diverter
C) forced through a type B vent by a blower
D) vented by natural convection
Question
Why do propane and butane gas furnaces require 100% shut off in the event of pilot outage?
Question
The flame in a gas fired furnace is burning with heavy yellow tips. What is the problem?
Question
Match between columns
blower located above heat exchanger
low boy
blower located above heat exchanger
upflow
blower located above heat exchanger
horizontal
blower located above heat exchanger
downflow
Question
Match between columns
primarily used in crawl spaces
low boy
primarily used in crawl spaces
upflow
primarily used in crawl spaces
horizontal
primarily used in crawl spaces
downflow
Question
Match between columns
blower located below heat exchanger
low boy
blower located below heat exchanger
upflow
blower located below heat exchanger
horizontal
blower located below heat exchanger
downflow
Question
Match between columns
return and supply ducts are both on top
low boy
return and supply ducts are both on top
upflow
return and supply ducts are both on top
horizontal
return and supply ducts are both on top
downflow
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 9: Gas Piping, Venting, and Appliance Efficiency
1
If there is too much primary air, the gas flame can ____.

A) get blown out
B) "lift" off the burner rack
C) make noise
D) both b and c
D
2
What is the difference between a yellow gas flame and an orange gas flame?
A yellow flame represents an air-starved flame-carbon monoxide is being produced! An orange flame represents the burning of dust-not dangerous.
3
When a gas furnace ignites and is under "full-fire," why does the fan not come on immediately?
The chamber must warm up first or the blower will circulate cold air.
4
In a conventional gas furnace, the hot flue gases are ____.

A) forced out a PVC vent with a blower
B) recycled through a secondary heat exchanger and then vented through a draft diverter
C) forced through a type B vent by a blower
D) vented by natural convection
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Why do propane and butane gas furnaces require 100% shut off in the event of pilot outage?
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
The flame in a gas fired furnace is burning with heavy yellow tips. What is the problem?
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
Match between columns
blower located above heat exchanger
low boy
blower located above heat exchanger
upflow
blower located above heat exchanger
horizontal
blower located above heat exchanger
downflow
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Match between columns
primarily used in crawl spaces
low boy
primarily used in crawl spaces
upflow
primarily used in crawl spaces
horizontal
primarily used in crawl spaces
downflow
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Match between columns
blower located below heat exchanger
low boy
blower located below heat exchanger
upflow
blower located below heat exchanger
horizontal
blower located below heat exchanger
downflow
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Match between columns
return and supply ducts are both on top
low boy
return and supply ducts are both on top
upflow
return and supply ducts are both on top
horizontal
return and supply ducts are both on top
downflow
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.