Deck 17: Hot-Water Heat

Full screen (f)
exit full mode
Question
The _________________________ allows for the expansion of heated water.
Use Space or
up arrow
down arrow
to flip the card.
Question
Hydronic systems circulate hot water or steam to the occupied space for heating purposes.
Question
____________________ in the system is removed by using air separators and air vents.
Question
The _________________________ is responsible for circulating the water through the system and is located so that it pumps away from the point of no pressure change.
Question
The ______________________________ opens and closes to maintain the desired water pressure in the system.
Question
_________________________ systems utilize monoflo or diverter tees to balance water flow.
Question
The ______________________________ cycles the boiler off in the event that the water level falls below a safe level.
Question
______________________________ return systems often use balancing valves to evenly distribute water flow through each branch.
Question
_________________________ are used to control water flow to different zones in the structure in order to maintain different temperatures in those areas.
Question
The ___________________________________ is a safety device that opens to relieve system pressure if it rises above the preset limit.
Question
The _________________________ uses the primary loop as the expansion tank.
Question
___________________________________ prevent gravity flow through hot water loops when the circulators are off.
Question
Hot water is typically generated in the boiler, which can be gas-fired, oil-fired, or electric.
Question
______________________________ pumping systems use circulators in both the primary and secondary loops.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 17: Hot-Water Heat
1
The _________________________ allows for the expansion of heated water.
expansion tank
2
Hydronic systems circulate hot water or steam to the occupied space for heating purposes.
True
3
____________________ in the system is removed by using air separators and air vents.
Air
4
The _________________________ is responsible for circulating the water through the system and is located so that it pumps away from the point of no pressure change.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
The ______________________________ opens and closes to maintain the desired water pressure in the system.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
_________________________ systems utilize monoflo or diverter tees to balance water flow.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
The ______________________________ cycles the boiler off in the event that the water level falls below a safe level.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
______________________________ return systems often use balancing valves to evenly distribute water flow through each branch.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
_________________________ are used to control water flow to different zones in the structure in order to maintain different temperatures in those areas.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
The ___________________________________ is a safety device that opens to relieve system pressure if it rises above the preset limit.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
The _________________________ uses the primary loop as the expansion tank.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
___________________________________ prevent gravity flow through hot water loops when the circulators are off.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
Hot water is typically generated in the boiler, which can be gas-fired, oil-fired, or electric.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
______________________________ pumping systems use circulators in both the primary and secondary loops.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 14 flashcards in this deck.