Deck 20: Screen-Film Radiographic Quality Control
1
Medical facilities have quality control programs in place in order to _________________.
A) have TJC approval and accreditation
B) ensure quality patient care
C) receive payment from insurance carriers
D) Do all of the above
A) have TJC approval and accreditation
B) ensure quality patient care
C) receive payment from insurance carriers
D) Do all of the above
Do all of the above
2
The determination of how consistently radiologists' image interpretations match patients' ultimate diagnoses is called _______________________.
A) exposure linearity
B) outcome analysis
C) reproducibility
D) uniformity
A) exposure linearity
B) outcome analysis
C) reproducibility
D) uniformity
outcome analysis
3
All general purpose radiographic units must have a minimum of _____ mm Al filtration.
A) 1.5
B) 2.0
C) 2.5
D) 3.0
A) 1.5
B) 2.0
C) 2.5
D) 3.0
2.5
4
The first step of the QA recommended by The Joint Commission (TJC) is to __________________.
A) collect and organize data
B) take action to improve care
C) assign responsibility
D) assess and document actions
A) collect and organize data
B) take action to improve care
C) assign responsibility
D) assess and document actions
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
5
A quality control program is for ____________________.
A) film processors
B) CT scanners
C) x-ray tubes
D) All of the above
A) film processors
B) CT scanners
C) x-ray tubes
D) All of the above
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
6
The minimum HVL for an x-ray machine operated at 70 kVp is _________________.
A) 1.0 mm Al
B) 5.0 mm Al
C) 2.0 mm Al
D) 20 mm Al
A) 1.0 mm Al
B) 5.0 mm Al
C) 2.0 mm Al
D) 20 mm Al
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
7
The x-ray field must center accurately to within ____% of SID.
A) 2
B) 3
C) 0.5
D) 1
A) 2
B) 3
C) 0.5
D) 1
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
8
A quality assurance program monitors __________.
A) films
B) imaging equipment
C) people
D) processors
A) films
B) imaging equipment
C) people
D) processors
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
9
Acceptance testing should never be done by a ______________________.
A) medical physicist
B) manufacturer's representative
C) QC technologist
D) radiologic engineer
A) medical physicist
B) manufacturer's representative
C) QC technologist
D) radiologic engineer
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
10
It is acceptable to perform a(n) _________ test instead of measuring the focal spot size.
A) line pair
B) exposure linearity
C) half-value layer
D) wire mesh pattern
A) line pair
B) exposure linearity
C) half-value layer
D) wire mesh pattern
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
11
Most quality control testing on radiographic equipment is done ______________.
A) annually
B) semiannually
C) monthly
D) weekly
A) annually
B) semiannually
C) monthly
D) weekly
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
12
When a light in a viewbox is out, _____________________.
A) that light bulb must be replaced
B) all bulbs in the viewbox must be replaced
C) all the bulbs must be matched to adjacent viewboxes
D) All of the above must be done
A) that light bulb must be replaced
B) all bulbs in the viewbox must be replaced
C) all the bulbs must be matched to adjacent viewboxes
D) All of the above must be done
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
13
Filtration is measured with _____________ measurements.
A) caliper
B) photometer
C) slit camera
D) half-value layer
A) caliper
B) photometer
C) slit camera
D) half-value layer
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
14
Comparing the mR output at 50 mA at 0.2 sec, 100 mA at 0.1 sec, and 200 mA at 0.05 sec is part of a test for ________________.
A) reciprocity
B) reproducibility
C) linearity
D) uniformity
A) reciprocity
B) reproducibility
C) linearity
D) uniformity
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
15
Quality control testing procedures should be performed on ______________ basis.
A) a daily and weekly
B) a monthly
C) an annual
D) All of the above
A) a daily and weekly
B) a monthly
C) an annual
D) All of the above
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
16
A QC program should include _________________, routine performance monitoring, and maintenance.
A) acceptance testing
B) outcome analysis
C) calibration
D) personnel monitoring
A) acceptance testing
B) outcome analysis
C) calibration
D) personnel monitoring
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
17
What is the testing device used to measure cassette screen-film contact?
A) Dosimeter
B) Wire-mesh
C) Sensitometer
D) Star pattern
A) Dosimeter
B) Wire-mesh
C) Sensitometer
D) Star pattern
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
18
The collimator must be accurately aligned to within ±_____% of the SID.
A) 2
B) 5
C) 10
D) 12
A) 2
B) 5
C) 10
D) 12
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
19
The measured kVp should be within ±_____% of the kVp indicated on the console.
A) 5
B) 10
C) 15
D) 20
A) 5
B) 10
C) 15
D) 20
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
20
Focal spot size is measured with ________________.
A) a pinhole camera
B) a star pattern
C) a slit camera
D) All of the above
A) a pinhole camera
B) a star pattern
C) a slit camera
D) All of the above
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
21
Following a good processor QC program reduces the need for __________ maintenance.
A) daily
B) unscheduled
C) scheduled
D) preventive
A) daily
B) unscheduled
C) scheduled
D) preventive
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
22
A positive beam limitation (PBL) device is involved in __________________.
A) collimation
B) exposure control
C) dose reduction
D) protocol monitoring
A) collimation
B) exposure control
C) dose reduction
D) protocol monitoring
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
23
Probably the most important patient protection characteristic of a radiographic imaging system is ______________.
A) filtration
B) focal spot size
C) accurate collimation
D) high contrast resolution
A) filtration
B) focal spot size
C) accurate collimation
D) high contrast resolution
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck