Deck 4: Oscilloscopes and Dsos

Full screen (f)
exit full mode
Question
A signal showing the voltage of a battery displayed on an analog oscilloscope is being discussed. Technician A says that the display will show one horizontal line above the zero line. Technician B says that the display will show a line sloping upward from zero to the battery voltage level. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Use Space or
up arrow
down arrow
to flip the card.
Question
A TP sensor signal voltage is being observed using a digital storage oscilloscope. The pattern on the scope occasionally rises to the source voltage level. What does this indicate?

A) Normal operation
B) A momentary short in the TP sensor
C) A momentary open circuit
D) A fault with the scope leads
Question
Two technicians are discussing pulse train signals. Technician A says that a pulse train is a DC signal waveform that goes above and below zero volts. Technician B says that a pulse train is a DC voltage that turns on and off in a series of pulses and they do not go below zero. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
Which type of oscilloscope displays all voltages without taking samples?

A) Complex
B) Analog
C) Digital
D) None of these
Question
Technician A says that analog scopes use an LCD display. Technician B says that digital scopes may use a CRT display. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
A digital storage oscilloscope is set to begin displaying a waveform when a certain voltage is detected. This minimum voltage is called ________.

A) threshold
B) trigger
C) trip
D) None of these
Question
A typical DSO display screen is arranged in an ________ grid.

A) 6 × 8
B) 8 × 10
C) 8 × 8
D) None of these
Question
Technician A says that voltage is usually indicated on the horizontal display axis. Technician B says that time is usually indicated on the horizontal display axis. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Question
________ the time base setting reduces the number of samples per second.

A) Increasing
B) Dividing
C) Decreasing
D) None of these
Question
A time base setting of 1ms/div will show a total time of ________ on the scope display

A) 100 ms
B) 1 ms
C) 10 ms
D) None of these
Question
Which is the correct voltage division setting for testing a throttle position sensor?

A) 1V
B) 3V
C) 5V
D) 10V
Question
Which of these is measured as a percentage?

A) Pulse width
B) Duty cycle
C) Dwell
D) None of these
Question
Which of these terms is a measure of the actual on-time measured in milliseconds?

A) Period
B) Pulse width
C) Frequency
D) Amplitude
Question
A DSO and a ________ are useful tools when diagnosing a fuel pump circuit.

A) hose clamp
B) current clamp
C) vacuum transducer
D) test light
Question
With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________. <strong>With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________.  </strong> A) 8 volts; 500mS B) 1 volt; 1 second C) 1 volt; 500 mS D) None of these <div style=padding-top: 35px>

A) 8 volts; 500mS
B) 1 volt; 1 second
C) 1 volt; 500 mS
D) None of these
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 4: Oscilloscopes and Dsos
1
A signal showing the voltage of a battery displayed on an analog oscilloscope is being discussed. Technician A says that the display will show one horizontal line above the zero line. Technician B says that the display will show a line sloping upward from zero to the battery voltage level. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
A
2
A TP sensor signal voltage is being observed using a digital storage oscilloscope. The pattern on the scope occasionally rises to the source voltage level. What does this indicate?

A) Normal operation
B) A momentary short in the TP sensor
C) A momentary open circuit
D) A fault with the scope leads
B
3
Two technicians are discussing pulse train signals. Technician A says that a pulse train is a DC signal waveform that goes above and below zero volts. Technician B says that a pulse train is a DC voltage that turns on and off in a series of pulses and they do not go below zero. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
B
4
Which type of oscilloscope displays all voltages without taking samples?

A) Complex
B) Analog
C) Digital
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Technician A says that analog scopes use an LCD display. Technician B says that digital scopes may use a CRT display. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
A digital storage oscilloscope is set to begin displaying a waveform when a certain voltage is detected. This minimum voltage is called ________.

A) threshold
B) trigger
C) trip
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
A typical DSO display screen is arranged in an ________ grid.

A) 6 × 8
B) 8 × 10
C) 8 × 8
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Technician A says that voltage is usually indicated on the horizontal display axis. Technician B says that time is usually indicated on the horizontal display axis. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
________ the time base setting reduces the number of samples per second.

A) Increasing
B) Dividing
C) Decreasing
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
A time base setting of 1ms/div will show a total time of ________ on the scope display

A) 100 ms
B) 1 ms
C) 10 ms
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Which is the correct voltage division setting for testing a throttle position sensor?

A) 1V
B) 3V
C) 5V
D) 10V
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Which of these is measured as a percentage?

A) Pulse width
B) Duty cycle
C) Dwell
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Which of these terms is a measure of the actual on-time measured in milliseconds?

A) Period
B) Pulse width
C) Frequency
D) Amplitude
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
A DSO and a ________ are useful tools when diagnosing a fuel pump circuit.

A) hose clamp
B) current clamp
C) vacuum transducer
D) test light
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________. <strong>With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________.  </strong> A) 8 volts; 500mS B) 1 volt; 1 second C) 1 volt; 500 mS D) None of these

A) 8 volts; 500mS
B) 1 volt; 1 second
C) 1 volt; 500 mS
D) None of these
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck