Deck 4: Understanding Grounding and Earthing in Electrical Systems
1
Which of the following decreases within turn decreases the charging rate?
A)temperature
B)pressure
C)enthalpy
D)entropy
A)temperature
B)pressure
C)enthalpy
D)entropy
temperature
2
Which of the following causes the corrosion of terminals and clamps?
A)spilled electrolyte
B)increase in temperature
C)decrease in pressure
D)due to high current
A)spilled electrolyte
B)increase in temperature
C)decrease in pressure
D)due to high current
spilled electrolyte
3
Grounding transformer is used where neutral .........available
A)is
B)is not
C)either a or b
D). none of the above
A)is
B)is not
C)either a or b
D). none of the above
is not
4
In equipment grounding, the enclosure is connected to ...........wire
A)ground
B)neutral
C)phase
D)either a or b
A)ground
B)neutral
C)phase
D)either a or b
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
5
Earthing is necessary to give protection against
A)danger of electric shock
B)voltage fluctuation
C)overloading
D)high temperature of the conductors
A)danger of electric shock
B)voltage fluctuation
C)overloading
D)high temperature of the conductors
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
6
In case of earth fault, the underground neutral system----------------lead to arcing ground
A)does
B)does not
C)any of above
D)none of above
A)does
B)does not
C)any of above
D)none of above
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
7
The advantage of neutral earthing
A)safety of personnel
B)reduction of earth fault current
C)elimination of arcing ground
D)none of the above
A)safety of personnel
B)reduction of earth fault current
C)elimination of arcing ground
D)none of the above
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
8
In a substation the equipment used to limit short circuit current level is
A)series reactor
B)coupling capacitor
C)lightening switch
D)isolator.
A)series reactor
B)coupling capacitor
C)lightening switch
D)isolator.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
9
In a star connected system without neutral grounding, zero sequence currents are
A)zero
B)phaser sum of phase currents
C)same as rms value of phase currents
D)same as peak value of phase currents
A)zero
B)phaser sum of phase currents
C)same as rms value of phase currents
D)same as peak value of phase currents
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
10
Grounding transformer is used where neutral available
A)is
B)is not
C)any of above
D)none of above
A)is
B)is not
C)any of above
D)none of above
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
11
Ground resistance value for sensitive installations is
A)less than 5 ?
B)more than 5 ?
C)equal to 50 ?
D)any of above
A)less than 5 ?
B)more than 5 ?
C)equal to 50 ?
D)any of above
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck