Question
A customer complains that the heater works sometimes, but sometimes only cold air comes out while Driving. Technician A says that the water pump is defective. Technician B says that the cooling system could be low on coolant. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Use Space or
up arrow
down arrow
to flip the card.
Question
Airflow through a typical HVAC system is being discussed. Technician A says that outside air is always used in all heating and cooling positions. Technician B says that the temperature is controlled by blending airflow through the evaporator and heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
The first step in the diagnostic procedure when attempting to solve an HVAC customer problem is ________.

A)Check for technical service bulletins
B)Visual inspection
C)Check for diagnostic trouble codes
D)Verify customer concern
Question
The last step in the diagnostic procedure is ________.

A)Recharge the system
B)Determine the root cause
C)Perform a visual inspection
D)Verify the repair
Question
Technician A says that one heater hose should be hot and the other hose cool if the heater is functioning okay. Technician B says that both hoses should be hot to the touch. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Nothing is seen in the sight glass (R-12 system). Technician A says that the system may be completely empty of refrigerant. Technician B says that the system may be completely charged. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says that evaporator leaks can be detected by installing dye into the system and looking for yellowish-green dye stains. Technician B says that a leak at the evaporator can be detected by removing the blower motor resistor pack and inserting an electronic leak detector probe into the air stream. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says that with a properly operating air-conditioning system, the inlet to the compressor should be cold and the outlet from the compressor hot. Technician B says that the condenser should be hot and the evaporator cold. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
A clogged orifice tube can cause a lack of cooling.
Question
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?

A)Turn the system off and allow the pressure to equalize
B)Overcharge the system by 10 oz.
C)Evacuate the system
D)Install dye in the system
Question
Technician A says heater temperature may be controlled by regulating the amount of coolant flowing Through the heater core. Technician B says heater temperature may be controlled by regulating the amount of air flowing through the heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says a thermostat which opens too soon can cause poor heater operation. Technician B says low coolant level can cause poor heater operation. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says AC system lines and hoses that are cold have lower refrigerant pressure than warmer lines and hoses. Technician B says frost on a system component usually indicates a refrigerant leak in that area. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says oily residue on hoses, components, or fittings indicates an area where refrigerant may be leaking. Technician B says damaged condenser fins may cause inefficient air conditioning operation at all blower speeds. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
The outlet line from the evaporator should be ________.

A)Frost-covered
B)Cool
C)Warm
D)Hot
Question
Technician A says electronic leak detectors make a noise when a leak is detected. Technician B says that often the same leak detector can be used for R-12 and R 134a. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
Technician A says refrigerant leaks are most common where components join together. Technician B says many manufacturers put leak-tracing dye in the refrigerant systems of new vehicles. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
An air conditioning performance check requires a ________.

A)Thermometer and a vacuum pump
B)Thermometer and a manifold gauge set
C)Manifold gauge set and a volt-ohmmeter
D)Thermometer and a hydrometer
Question
If both the low side and the high side show low readings, what might be the problem?

A)Condenser malfunction
B)Cooling fan malfunction
C)Low refrigerant charge
D)TXV stuck open
Question
Technician A checks ambient temperature as part of an AC performance test. Technician B says that if the AC compressor has not been operating, the high side and low side refrigerant pressure should be equal. Who is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Question
If the performance test shows less than 45° F at the center vent, the AC is working normally.
Question
On a cold day it is normal for the thermostat to stay closed for more than 15 minutes.
Question
An AC system has had about 0.5 lbs of R-22 refrigerant added. What would this cause?

A)Low high side pressures
B)Very high high side pressures
C)No problems, normal AC cooling
D)Increased cooling
Question
The ambient temperature is 70° F and the humidity is low. What should the high side gauge pressure be (AC system on)?

A)140 to 190 psi
B)300 to 350 psi
C)10 to 50 psi
D)Not enough information to tell
Question
It is 90°F in the shop and the humidity is high. What pressure will be shown on the high side pressure gauge (AC system on)?

A)10 to 50 psi
B)At least 350 psi
C)210 to 290 psi
D)40 to 140 psi
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 64: Heating and Air-Conditioning System Diagnosis
1
A customer complains that the heater works sometimes, but sometimes only cold air comes out while Driving. Technician A says that the water pump is defective. Technician B says that the cooling system could be low on coolant. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Technician B only
2
Airflow through a typical HVAC system is being discussed. Technician A says that outside air is always used in all heating and cooling positions. Technician B says that the temperature is controlled by blending airflow through the evaporator and heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Technician B only
3
The first step in the diagnostic procedure when attempting to solve an HVAC customer problem is ________.

A)Check for technical service bulletins
B)Visual inspection
C)Check for diagnostic trouble codes
D)Verify customer concern
Verify customer concern
4
The last step in the diagnostic procedure is ________.

A)Recharge the system
B)Determine the root cause
C)Perform a visual inspection
D)Verify the repair
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
Technician A says that one heater hose should be hot and the other hose cool if the heater is functioning okay. Technician B says that both hoses should be hot to the touch. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Nothing is seen in the sight glass (R-12 system). Technician A says that the system may be completely empty of refrigerant. Technician B says that the system may be completely charged. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Technician A says that evaporator leaks can be detected by installing dye into the system and looking for yellowish-green dye stains. Technician B says that a leak at the evaporator can be detected by removing the blower motor resistor pack and inserting an electronic leak detector probe into the air stream. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Technician A says that with a properly operating air-conditioning system, the inlet to the compressor should be cold and the outlet from the compressor hot. Technician B says that the condenser should be hot and the evaporator cold. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
A clogged orifice tube can cause a lack of cooling.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?

A)Turn the system off and allow the pressure to equalize
B)Overcharge the system by 10 oz.
C)Evacuate the system
D)Install dye in the system
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Technician A says heater temperature may be controlled by regulating the amount of coolant flowing Through the heater core. Technician B says heater temperature may be controlled by regulating the amount of air flowing through the heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Technician A says a thermostat which opens too soon can cause poor heater operation. Technician B says low coolant level can cause poor heater operation. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Technician A says AC system lines and hoses that are cold have lower refrigerant pressure than warmer lines and hoses. Technician B says frost on a system component usually indicates a refrigerant leak in that area. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Technician A says oily residue on hoses, components, or fittings indicates an area where refrigerant may be leaking. Technician B says damaged condenser fins may cause inefficient air conditioning operation at all blower speeds. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
The outlet line from the evaporator should be ________.

A)Frost-covered
B)Cool
C)Warm
D)Hot
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
Technician A says electronic leak detectors make a noise when a leak is detected. Technician B says that often the same leak detector can be used for R-12 and R 134a. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Technician A says refrigerant leaks are most common where components join together. Technician B says many manufacturers put leak-tracing dye in the refrigerant systems of new vehicles. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
An air conditioning performance check requires a ________.

A)Thermometer and a vacuum pump
B)Thermometer and a manifold gauge set
C)Manifold gauge set and a volt-ohmmeter
D)Thermometer and a hydrometer
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
If both the low side and the high side show low readings, what might be the problem?

A)Condenser malfunction
B)Cooling fan malfunction
C)Low refrigerant charge
D)TXV stuck open
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
Technician A checks ambient temperature as part of an AC performance test. Technician B says that if the AC compressor has not been operating, the high side and low side refrigerant pressure should be equal. Who is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
If the performance test shows less than 45° F at the center vent, the AC is working normally.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
On a cold day it is normal for the thermostat to stay closed for more than 15 minutes.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
An AC system has had about 0.5 lbs of R-22 refrigerant added. What would this cause?

A)Low high side pressures
B)Very high high side pressures
C)No problems, normal AC cooling
D)Increased cooling
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
The ambient temperature is 70° F and the humidity is low. What should the high side gauge pressure be (AC system on)?

A)140 to 190 psi
B)300 to 350 psi
C)10 to 50 psi
D)Not enough information to tell
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
It is 90°F in the shop and the humidity is high. What pressure will be shown on the high side pressure gauge (AC system on)?

A)10 to 50 psi
B)At least 350 psi
C)210 to 290 psi
D)40 to 140 psi
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.