Deck 39: Digital Imaging, Dental Film, and Processing Radiographs

Full screen (f)
exit full mode
Question
Automatic film processing requires _____ than manual film processing does.

A)more time
B)less equipment
C)more equipment
D)more space
Use Space or
up arrow
down arrow
to flip the card.
Question
The category of digital imaging similar to faxes and video equipment that uses a sensor with a cord attached to the computer is:

A)computed radiograph programs.
B)indirect digital radiography.
C)direct digital radiography.
D)none of the above.
Question
The extraoral film placed outside the mouth during x-ray exposure is:

A)periapical.
B)bite-wing.
C)panoramic.
D)occlusal.
Question
The most commonly used film size for adult intraoral dentistry is size:

A)#0.
B)#2.
C)#3.
D)#4.
Question
____ -speed film is the newest and fastest film currently available.

A)E
B)F
C)Ultra D
D)High speed E
Question
The radiographic image is located within the _____ of the radiographic film.

A)acetate film base
B)adhesive layer that attaches the emulsion to the film base
C)gelatin that suspends the emulsion
D)protective layer that protects the emulsion surface
Question
The device that intensifies or increases the effect of the radiation and decreases the amount of exposure time needed when exposing an extraoral radiograph is a(n):

A)screen film.
B)film cassette.
C)intensifying screen.
D)nonscreen film.
Question
The CCD in direct digital imaging sensors is made of:

A)silicon.
B)phosphor.
C)tungsten.
D)silver halide.
Question
All the following are true statements about image plates except they:

A)need to be protected in the patient's mouth with barriers.
B)should be autoclaved.
C)require care not to scratch when handling.
D)are positioned in the mouth like dental film.
Question
Film speed is determined by the:

A)thickness of silver bromide salt.
B)thickness of cellulose acetate base.
C)size of the silver bromide crystals.
D)Both a and c are correct.
Question
A plastic or metal film cassette holds and protects the extraoral film.During exposure,the side of the cassette the must face the patient is the _____ side.

A)front
B)back
C)right
D)left
Question
_____ hardens the film emulsion during film processing.

A)Rinsing
B)Developing
C)Fixing
D)Washing
Question
Developer cutoff will result in a _____ border.

A)straight white
B)straight black
C)curved white
D)curved black
Question
The purpose of the lead foil in the dental film packet is to:

A)provide stiffness to the film.
B)reduce film fogging.
C)absorb the primary beam.
D)make the packet more flexible and resilient.
Question
Dental film holders,used to position and hold the dental x-ray films in the patient's mouth,include:

A)PID.
B)XCP and disposable block.
C)EeZee-Grip and EndoRay.
D)both b and c
Question
Positioning instruments in digital radiography:

A)assist in film placement.
B)keep the patient's fingers from being exposed.
C)should not be used.
D)Both a and b are correct.
Question
All of following are true statements about storage plates used with (PSP)except:

A)they are made of phosphor.
B)the latent image will stay on the plate for hours.
C)they should not be exposed to light before scanning.
D)they are disposable.
Question
Which of the following time and temperature errors will result in reticulation of the film emulsion?

A)Inadequate development time
B)Developer solution too hot
C)Sudden temperature change between developer and water bath
D)Inaccurate timer or thermometer
Question
All the following are true statements about the emulsion on a duplicating film except that it:

A)is only on one side.
B)appears shiny.
C)appears dull.
D)is exposed by light.
Question
When placing a dental film in the patient's mouth,the white side is placed ____ the tube and the raised dot to the ____.

A)toward; apical
B)toward; occlusal or incisal
C)away; apical
D)away; occlusal or incisal
Question
When film emulsion interacts with x-rays,the result is:

A)a visible distortion.
B)a distorted light source.
C)a latent image.
D)none of the above.
Question
The safest place to store unopened boxes of dental film is in the:

A)darkroom.
B)furnace room.
C)refrigerator.
D)treatment room.
Question
The correct order of steps in manual film processing is:

A)fix, rinse, develop, wash.
B)develop, rinse, fix, wash.
C)fix, wash, rinse, wash.
D)rinse, develop, fix, wash.
Question
An extraoral dental x-ray film is:

A)not sensitive to light.
B)less sensitive to light than intraoral film.
C)just as sensitive to light as intraoral film.
D)more sensitive to light than intraoral film.
Question
Clear spots on a processed film can be caused by:

A)static electricity.
B)solutions are too warm.
C)fixer contacts film prior to processing.
D)drops of developer on a fixed film.
Question
The life of the processing solutions is affected by:

A)the number of films processed.
B)the time elapsed since last change.
C)the size of films processed.
D)all of the above.
Question
One reason for a lighter than normal radiograph is the:

A)developer solution is too weak.
B)developer solution is too warm.
C)fixer solution is too weak.
D)film was not properly rinsed.
Question
The recommended distance between the safelight and where the films are unwrapped is:

A)2 feet.
B)4 feet.
C)6 feet.
D)as close as possible.
Question
Digital radiography requires less radiation than traditional radiography because the:

A)exposure time is increased.
B)sensor is smaller.
C)sensor is more sensitive to x-ray energy.
D)sensor is attached to the computer.
Question
When developer solution in an automatic processor is warmer than 83° F,the processed film will appear:

A)dark or black.
B)gray.
C)clear.
D)light.
Question
When loading the film into the cassette before exposure (in extraoral radiography),the:

A)film comes preloaded in the cassette.
B)procedure must be done in the darkroom.
C)film may be placed in the holder outside the darkroom.
D)film does not need an intensifying screen.
Question
All the following are true statements about digitizing film-based radiographs except:

A)the process is similar to other film duplication.
B)desktop scanners capture the light signal.
C)it duplicates the same detail as the original film.
D)All of the above are true.
Question
Solutions should have been changed in the processor 1 week ago.Continuing to use exhausted developer will result in ____ films.

A)dark
B)light
C)white
D)clear
Question
The ideal time and temperature for manual developing is:

A)45 seconds at 85° F.
B)5 minutes at 65° C.
C)5 minutes at 68° F.
D)5 minutes at 60° F.
Question
When a film passes through fixer solutions before developing,the film will appear:

A)clear.
B)completely black.
C)gray.
D)yellowish-brown.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/35
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 39: Digital Imaging, Dental Film, and Processing Radiographs
1
Automatic film processing requires _____ than manual film processing does.

A)more time
B)less equipment
C)more equipment
D)more space
less equipment
2
The category of digital imaging similar to faxes and video equipment that uses a sensor with a cord attached to the computer is:

A)computed radiograph programs.
B)indirect digital radiography.
C)direct digital radiography.
D)none of the above.
direct digital radiography.
3
The extraoral film placed outside the mouth during x-ray exposure is:

A)periapical.
B)bite-wing.
C)panoramic.
D)occlusal.
panoramic.
4
The most commonly used film size for adult intraoral dentistry is size:

A)#0.
B)#2.
C)#3.
D)#4.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
5
____ -speed film is the newest and fastest film currently available.

A)E
B)F
C)Ultra D
D)High speed E
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
6
The radiographic image is located within the _____ of the radiographic film.

A)acetate film base
B)adhesive layer that attaches the emulsion to the film base
C)gelatin that suspends the emulsion
D)protective layer that protects the emulsion surface
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
7
The device that intensifies or increases the effect of the radiation and decreases the amount of exposure time needed when exposing an extraoral radiograph is a(n):

A)screen film.
B)film cassette.
C)intensifying screen.
D)nonscreen film.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
8
The CCD in direct digital imaging sensors is made of:

A)silicon.
B)phosphor.
C)tungsten.
D)silver halide.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
9
All the following are true statements about image plates except they:

A)need to be protected in the patient's mouth with barriers.
B)should be autoclaved.
C)require care not to scratch when handling.
D)are positioned in the mouth like dental film.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
10
Film speed is determined by the:

A)thickness of silver bromide salt.
B)thickness of cellulose acetate base.
C)size of the silver bromide crystals.
D)Both a and c are correct.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
11
A plastic or metal film cassette holds and protects the extraoral film.During exposure,the side of the cassette the must face the patient is the _____ side.

A)front
B)back
C)right
D)left
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
12
_____ hardens the film emulsion during film processing.

A)Rinsing
B)Developing
C)Fixing
D)Washing
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
13
Developer cutoff will result in a _____ border.

A)straight white
B)straight black
C)curved white
D)curved black
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
14
The purpose of the lead foil in the dental film packet is to:

A)provide stiffness to the film.
B)reduce film fogging.
C)absorb the primary beam.
D)make the packet more flexible and resilient.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
15
Dental film holders,used to position and hold the dental x-ray films in the patient's mouth,include:

A)PID.
B)XCP and disposable block.
C)EeZee-Grip and EndoRay.
D)both b and c
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
16
Positioning instruments in digital radiography:

A)assist in film placement.
B)keep the patient's fingers from being exposed.
C)should not be used.
D)Both a and b are correct.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
17
All of following are true statements about storage plates used with (PSP)except:

A)they are made of phosphor.
B)the latent image will stay on the plate for hours.
C)they should not be exposed to light before scanning.
D)they are disposable.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
18
Which of the following time and temperature errors will result in reticulation of the film emulsion?

A)Inadequate development time
B)Developer solution too hot
C)Sudden temperature change between developer and water bath
D)Inaccurate timer or thermometer
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
19
All the following are true statements about the emulsion on a duplicating film except that it:

A)is only on one side.
B)appears shiny.
C)appears dull.
D)is exposed by light.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
20
When placing a dental film in the patient's mouth,the white side is placed ____ the tube and the raised dot to the ____.

A)toward; apical
B)toward; occlusal or incisal
C)away; apical
D)away; occlusal or incisal
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
21
When film emulsion interacts with x-rays,the result is:

A)a visible distortion.
B)a distorted light source.
C)a latent image.
D)none of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
22
The safest place to store unopened boxes of dental film is in the:

A)darkroom.
B)furnace room.
C)refrigerator.
D)treatment room.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
23
The correct order of steps in manual film processing is:

A)fix, rinse, develop, wash.
B)develop, rinse, fix, wash.
C)fix, wash, rinse, wash.
D)rinse, develop, fix, wash.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
24
An extraoral dental x-ray film is:

A)not sensitive to light.
B)less sensitive to light than intraoral film.
C)just as sensitive to light as intraoral film.
D)more sensitive to light than intraoral film.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
25
Clear spots on a processed film can be caused by:

A)static electricity.
B)solutions are too warm.
C)fixer contacts film prior to processing.
D)drops of developer on a fixed film.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
26
The life of the processing solutions is affected by:

A)the number of films processed.
B)the time elapsed since last change.
C)the size of films processed.
D)all of the above.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
27
One reason for a lighter than normal radiograph is the:

A)developer solution is too weak.
B)developer solution is too warm.
C)fixer solution is too weak.
D)film was not properly rinsed.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
28
The recommended distance between the safelight and where the films are unwrapped is:

A)2 feet.
B)4 feet.
C)6 feet.
D)as close as possible.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
29
Digital radiography requires less radiation than traditional radiography because the:

A)exposure time is increased.
B)sensor is smaller.
C)sensor is more sensitive to x-ray energy.
D)sensor is attached to the computer.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
30
When developer solution in an automatic processor is warmer than 83° F,the processed film will appear:

A)dark or black.
B)gray.
C)clear.
D)light.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
31
When loading the film into the cassette before exposure (in extraoral radiography),the:

A)film comes preloaded in the cassette.
B)procedure must be done in the darkroom.
C)film may be placed in the holder outside the darkroom.
D)film does not need an intensifying screen.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
32
All the following are true statements about digitizing film-based radiographs except:

A)the process is similar to other film duplication.
B)desktop scanners capture the light signal.
C)it duplicates the same detail as the original film.
D)All of the above are true.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
33
Solutions should have been changed in the processor 1 week ago.Continuing to use exhausted developer will result in ____ films.

A)dark
B)light
C)white
D)clear
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
34
The ideal time and temperature for manual developing is:

A)45 seconds at 85° F.
B)5 minutes at 65° C.
C)5 minutes at 68° F.
D)5 minutes at 60° F.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
35
When a film passes through fixer solutions before developing,the film will appear:

A)clear.
B)completely black.
C)gray.
D)yellowish-brown.
Unlock Deck
Unlock for access to all 35 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 35 flashcards in this deck.