Deck 47: Coagulation Instrumentation

Full screen (f)
exit full mode
Question
Aspirin-induced bleeding and Willebrand disease (VWD), type 1, are detected reliably by:

A) Bleeding time
B) Point-of-care testing (POCT)
C) PFA 100 Platelet Function Analyzer
D) Nephelometry
Use Space or
up arrow
down arrow
to flip the card.
Question
Which single instrument development has been the most important improvement in coagulation instrumentation?

A) Multiple-sample dilutions
B) Improved flagging
C) Random access testing
D) Graphing of clot formation
Question
Which of the following assays uses indirect measurement using a chromogenic substrate to quantitate heparin?

A) Protein C
B) Thrombin time (TT)
C) Anti-Xa assay
D) Fibrinogen assay
Question
Examples of instrument malfunction flags include all of the following except:

A) Temperature error
B) Probe not aspirating
C) No end point detected
D) Hemolysis
Question
Using which principle does plasma become more opaque as a clot forms and the amount of light being detected decreases?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Question
Automatic performance of certain tests based on the results of other tests is called:

A) Reflex testing
B) Interpretive liberty
C) Programming flexibility
D) Random access
Question
Who should select the coagulation instruments for a given laboratory?

A) Laboratory director
B) Department manager
C) Clinical laboratory scientists
D) All of the previously listed individuals working together
Question
Which of the following is the most common clot detection principle used for coagulation testing?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Question
Diagnostica Stago coagulation instruments are based on what clot detection principle?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Nephelometric
Question
Which of the following most improved safety for laboratory scientists?

A) Closed tube sampling
B) Random access
C) Expanded computer capabilities
D) Improved flagging capabilities
Question
All of the following are considered routine coagulation tests that are available in most large and small clinical laboratories except:

A) Prothrombin time (PT)
B) Fibrinogen assay
C) Partial thromboplastin time (PTT)
D) Antithrombin assay
Question
What is the greatest disadvantage to photo-optical coagulation instruments?

A) High cost
B) Complexity of operation
C) Availability is limited
D) Interference from lipemia, hemolysis, and hyperbilirubinemia
Question
Which of the following principles measures the actual coagulation protein rather than fibrin formation?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Question
Which of the following is true regarding advances in automated coagulation instrumentation?

A) Less staff training is required to operate and maintain the equipment than earlier semiautomatic instruments.
B) Single-sample testing is possible because of increased precision.
C) Newer instruments are less expensive.
D) Accuracy is so improved that controls do not need to be run.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 47: Coagulation Instrumentation
1
Aspirin-induced bleeding and Willebrand disease (VWD), type 1, are detected reliably by:

A) Bleeding time
B) Point-of-care testing (POCT)
C) PFA 100 Platelet Function Analyzer
D) Nephelometry
PFA 100 Platelet Function Analyzer
2
Which single instrument development has been the most important improvement in coagulation instrumentation?

A) Multiple-sample dilutions
B) Improved flagging
C) Random access testing
D) Graphing of clot formation
Random access testing
3
Which of the following assays uses indirect measurement using a chromogenic substrate to quantitate heparin?

A) Protein C
B) Thrombin time (TT)
C) Anti-Xa assay
D) Fibrinogen assay
Anti-Xa assay
4
Examples of instrument malfunction flags include all of the following except:

A) Temperature error
B) Probe not aspirating
C) No end point detected
D) Hemolysis
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
Using which principle does plasma become more opaque as a clot forms and the amount of light being detected decreases?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
Automatic performance of certain tests based on the results of other tests is called:

A) Reflex testing
B) Interpretive liberty
C) Programming flexibility
D) Random access
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
Who should select the coagulation instruments for a given laboratory?

A) Laboratory director
B) Department manager
C) Clinical laboratory scientists
D) All of the previously listed individuals working together
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
Which of the following is the most common clot detection principle used for coagulation testing?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
Diagnostica Stago coagulation instruments are based on what clot detection principle?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Nephelometric
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
Which of the following most improved safety for laboratory scientists?

A) Closed tube sampling
B) Random access
C) Expanded computer capabilities
D) Improved flagging capabilities
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
All of the following are considered routine coagulation tests that are available in most large and small clinical laboratories except:

A) Prothrombin time (PT)
B) Fibrinogen assay
C) Partial thromboplastin time (PTT)
D) Antithrombin assay
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
What is the greatest disadvantage to photo-optical coagulation instruments?

A) High cost
B) Complexity of operation
C) Availability is limited
D) Interference from lipemia, hemolysis, and hyperbilirubinemia
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following principles measures the actual coagulation protein rather than fibrin formation?

A) Photo-optical
B) Mechanical
C) Chromogenic
D) Immunologic
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following is true regarding advances in automated coagulation instrumentation?

A) Less staff training is required to operate and maintain the equipment than earlier semiautomatic instruments.
B) Single-sample testing is possible because of increased precision.
C) Newer instruments are less expensive.
D) Accuracy is so improved that controls do not need to be run.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 14 flashcards in this deck.