Exercise 3
A V-6 is being checked for starter amperage draw. The initial surge current was about 210 amperes and about 160 amperes during cranking. Technician A says the starter is defective and should be replaced because the current flow exceeds 200 amperes. Technician B says this is normal current draw for a starter motor on a V-6 engine. Which technician is correct?
A) Technician A only
B) Technician B only
C) Both Technicians A and B
D) Neither Technician A nor B
Explanation
Verified
like image
like image

The 6-cylinder engines have current rati...