An abc -phase-sequence balanced three-phase source feeds a balanced load. The system is connected wye-wye and V an = 0°. The line impedance is 0.5 + j 0.2 , the load impedance is 16 + j 10 , and the total power absorbed by the load is 2000 W. Determine the magnitude of the source voltage V an.
Explanation
Verified
like image
like image

Consider the circuit diagram shown in Fi...