A 50 transmission line is terminated with a resistive load of 120 ft impedance. A generator puts a signal with a frequency of 70 MHz and a power level of 20 dBm into the other end of the line. The line has a velocity factor of 0.8.
(a) Calculate the reflection coefficient at the load.
(b) Calculate the voltage standing-wave ratio at the load.
(c) How much power is dissipated by the load
(d) Design a quarter-wave transformer that could be installed at the load to match it to the line. Sketch the transformer and calculate its length and characteristic impedance.
(a) Calculate the reflection coefficient at the load.
(b) Calculate the voltage standing-wave ratio at the load.
(c) How much power is dissipated by the load
(d) Design a quarter-wave transformer that could be installed at the load to match it to the line. Sketch the transformer and calculate its length and characteristic impedance.
Explanation
(a)
Due to impedance discontinuity in th...