Deck 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher

Full screen (f)
exit full mode
Question
Dishwashers and kitchen waste disposers may be connected to any of the required 20-ampere small-appliance branch circuits in the kitchen.
Use Space or
up arrow
down arrow
to flip the card.
Question
NEC 210.23(A)(2) limits cord-connected equipment to ____________________ percent of the branch-circuit ampere rating.
Question
The two general methods of connecting food-waste disposers are hard-wired and ____________________.
Question
Article ____, Part VI, covers equipment grounding and equipment grounding conductors.

A) 210
B) 250
C) 400
D) 422
Question
A duplex grounding-type receptacle is usually installed in an accessible location under the sink for plugging in the dishwasher and food waste disposer, and it does not have to be ____ protected.

A) AFCI
B) GFCI
C) assured grounding conductor
D) IDCI
Question
Because of the problem of people being scalded, many municipalities and states have implemented code requirements that water heater thermostats be set at not over 120 degrees F (49 degrees C).
Question
Small-appliance circuits are intended to serve countertops for cord-connected ____ appliances only.

A) under 1/3 horsepower
B) portable
C) fixed-in-place
D) none of the above
Question
Portable dishwashers are supplied with a 3-wire cord and plug. If the 3-wire plug cap is plugged into a properly connected ____________________ receptacle, the dishwasher is adequately grounded.
Question
Explain why a 125-volt, 15- or 20-ampere receptacle installed in an under-cabinet space to supply a dishwasher and/or food-waste disposer is not required to have GFCI protection for personnel.
Question
Per the specifications, the branch-circuit conductors for food waste disposers and dishwashers are ____ AWG.

A) 6
B) 12
C) 24
D) 36
Question
The maximum flexible cord length permitted for a kitchen waste disposer is ____.

A) 18 in. (450 mm)
B) 24 in. (600 mm)
C) 3 ft (900 mm)
D) 6 ft (1.8 m)
Question
A dual-element fuse sized at approximately 125% of the full-load current rating of the motor adds extra overcurrent protection to the overload protection built into a food-waste disposer.
Question
All motor-driven appliances must be provided with a means disconnecting the appliance from the ungrounded conductors. The branch-circuit breaker can serve as the disconnecting means if within sight of the appliance or capable of being ____________________.
Question
When a food-waste disposer has an integral ON-OFF switch, an additional separately installed switch ____ required.

A) is
B) is not
Question
Lock-off provisions for appliances must be permanently installed on the ____________________ or switch.
Question
The Code Article that specifically addresses electrical appliances is ____________________.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/16
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher
1
Dishwashers and kitchen waste disposers may be connected to any of the required 20-ampere small-appliance branch circuits in the kitchen.
False
2
NEC 210.23(A)(2) limits cord-connected equipment to ____________________ percent of the branch-circuit ampere rating.
80
eighty
3
The two general methods of connecting food-waste disposers are hard-wired and ____________________.
cord-and-plug connection
cord and plug connection
4
Article ____, Part VI, covers equipment grounding and equipment grounding conductors.

A) 210
B) 250
C) 400
D) 422
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
5
A duplex grounding-type receptacle is usually installed in an accessible location under the sink for plugging in the dishwasher and food waste disposer, and it does not have to be ____ protected.

A) AFCI
B) GFCI
C) assured grounding conductor
D) IDCI
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
6
Because of the problem of people being scalded, many municipalities and states have implemented code requirements that water heater thermostats be set at not over 120 degrees F (49 degrees C).
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
7
Small-appliance circuits are intended to serve countertops for cord-connected ____ appliances only.

A) under 1/3 horsepower
B) portable
C) fixed-in-place
D) none of the above
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
8
Portable dishwashers are supplied with a 3-wire cord and plug. If the 3-wire plug cap is plugged into a properly connected ____________________ receptacle, the dishwasher is adequately grounded.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
9
Explain why a 125-volt, 15- or 20-ampere receptacle installed in an under-cabinet space to supply a dishwasher and/or food-waste disposer is not required to have GFCI protection for personnel.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
10
Per the specifications, the branch-circuit conductors for food waste disposers and dishwashers are ____ AWG.

A) 6
B) 12
C) 24
D) 36
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
11
The maximum flexible cord length permitted for a kitchen waste disposer is ____.

A) 18 in. (450 mm)
B) 24 in. (600 mm)
C) 3 ft (900 mm)
D) 6 ft (1.8 m)
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
12
A dual-element fuse sized at approximately 125% of the full-load current rating of the motor adds extra overcurrent protection to the overload protection built into a food-waste disposer.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
13
All motor-driven appliances must be provided with a means disconnecting the appliance from the ungrounded conductors. The branch-circuit breaker can serve as the disconnecting means if within sight of the appliance or capable of being ____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
14
When a food-waste disposer has an integral ON-OFF switch, an additional separately installed switch ____ required.

A) is
B) is not
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
15
Lock-off provisions for appliances must be permanently installed on the ____________________ or switch.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
16
The Code Article that specifically addresses electrical appliances is ____________________.
Unlock Deck
Unlock for access to all 16 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 16 flashcards in this deck.