Deck 18: Lighting Branch Circuit, Receptacle Circuits for Workshop
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/21
Play
Full screen (f)
Deck 18: Lighting Branch Circuit, Receptacle Circuits for Workshop
1
What does NEC 406.5(C) prohibit?
It prohibits mounting and supporting a receptacle to a cover by only one screw unless the device assembly or box cover is listed and identified for securing by a single screw.
2
The branch circuit feeding the required laundry receptacle ____ permitted to supply other dedicated equipment in the laundry room, including lighting and an exhaust fan.
A) is
B) is not
A) is
B) is not
B
3
The NEC fill calculations for a conduit nipple not over 24 in. (600 mm) allows what fill percentage for three or more conductors?
A) 31%
B) 40%
C) 53%
D) 60%
A) 31%
B) 40%
C) 53%
D) 60%
D
4
What Code section makes it mandatory to install at least one receptacle outlet in each unfinished basement area?
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
5
The derating factor that must be used when four to six current-carrying conductors are installed in a conduit is ____ percent.
A) 50
B) 70
C) 80
D) none of the above
A) 50
B) 70
C) 80
D) none of the above
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
6
When a nonmetallic wiring method is installed where short sections of metal raceway are provided for mechanical protection-or for appearance-these short sections of raceway ____ be grounded.
A) need not
B) need to
A) need not
B) need to
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
7
In many parts of the country, the wiring method in unfinished basements is ____ in the ceiling and EMT on the walls for receptacles and switches.
A) metallic-sheathed cable
B) nonmetallic cable
C) nonmetallic-sheathed cable
D) armored cable
A) metallic-sheathed cable
B) nonmetallic cable
C) nonmetallic-sheathed cable
D) armored cable
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
8
The NEC requires that all 125-volt, ____, 15- or 20-ampere receptacles installed in unfinished basements must be GFCI protected.
A) two-phase
B) multi-wire
C) single-phase
D) ungrounded
A) two-phase
B) multi-wire
C) single-phase
D) ungrounded
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
9
When a single receptacle of any rating is installed on an individual branch circuit, the receptacle rating must not be ____ than the rating of the branch circuit.
A) more
B) less
A) more
B) less
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
10
When metal raceways are used in house construction, in most cases the type of raceway will be ____________________.
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
11
The advantage(s) of pull-chain switches for lighting fixtures include ____.
A) local control of task lighting
B) energy conservation
C) increased safety from wall switches
D) both a and b
A) local control of task lighting
B) energy conservation
C) increased safety from wall switches
D) both a and b
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
12
Some additional rules apply when nonmetallic-sheathed cable and armored cable are ____, because of possible physical damage to the cables.
A) run exposed
B) present
C) run unexposed
D) connected
A) run exposed
B) present
C) run unexposed
D) connected
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
13
The circuit feeding the required laundry area receptacle(s) shall have ____ outlets connected to it.
A) no other
B) no more than one other
C) only one other
D) an unlimited number of
A) no other
B) no more than one other
C) only one other
D) an unlimited number of
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
14
Many electrical ordinances require that a separate equipment grounding conductor be installed in all raceways, whether rigid or flexible, whether ____________________.
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
15
All 125-volt, single-phase, 15 or 20-ampere receptacles installed in ____________________ basements must be GFCI protected.
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
16
For the typical ____________________, the duplex receptacle would be fastened to it by two small No. 6-32 bolts and nuts.
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
17
To ensure that the conductor insulation will not be injured, be sure to ream the cut ends of rigid conduit and electrical metallic tubing to remove ____.
A) rough edges
B) loose ends
C) burrs
D) both a and c
A) rough edges
B) loose ends
C) burrs
D) both a and c
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
18
When transitions between cable and conduit must be made, usually this will be a(n) ____________________.
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
19
Raceways ____ required be installed as a complete system between pull points before pulling in the wires.
A) are
B) are not
A) are
B) are not
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
20
Many workshop fluorescent luminaires are furnished with a 3-wire (____) flexible cord suitable for the purpose that has the attachment plug cap factory-attached to the cord.
A) black, white, green
B) black, white, orange
C) black, red, green
D) grey, white, green
A) black, white, green
B) black, white, orange
C) black, red, green
D) grey, white, green
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck
21
A(n) ____________________ conductor carrying the unbalanced currents from the other conductors need not be counted when determining the ampacity of the conductor, according to NEC 310.15(B)(5)(a).
Unlock Deck
Unlock for access to all 21 flashcards in this deck.
Unlock Deck
k this deck