Deck 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic

Full screen (f)
exit full mode
Question
Prior to the 1996 NEC, ____ receptacles and cords were permitted. However, now it is mandatory that a separate equipment grounding conductor be installed to ground the frames of electric clothes dryers and electric ranges.

A) 3-wire
B) 16 AWG
C) 4-wire
D) listed
Use Space or
up arrow
down arrow
to flip the card.
Question
For most residential electric ____, receptacles and cord sets are rated 30 amperes, 125/250 volts.

A) washers and dryers
B) clothes dryers
C) washers
D) ranges
Question
A powder room is considered a bathroom if it contains a(n) ____________________ and a toilet, urinal, tub, shower, bidet, or similar plumbing fixture.
Question
If an electric clothes dryer or electric range is to be installed in a residence where the dryer branch-circuit wiring had been installed according to pre-1996 NEC rules, how is the dryer frame grounded?
Question
The special permission that was put into effect in July of 1942 allowed the neutral conductor to serve a dual purpose as the neutral conductor and the ____________________.
Question
NEC 210.52(F) requires a(n) ____________________ in one-family dwellings.
Question
NEC 210.70(A)(3) addresses ____ that are used for storage and attics that contain equipment that might need servicing, such as air-conditioning equipment.

A) powder rooms
B) crawlspace areas
C) basements
D) attics
Question
When running cables parallel to framing members, at least ____________________ inches must be maintained between the cable and the edge of the framing member.
Question
Electric washer/dryer combinations generally require a ____-ampere branch circuit similar to that required for a typical electric clothes dryer.

A) 10
B) 20
C) 30
D) 40
Question
The NEC requires that an appliance nameplate show ____.

A) the appliance rating in volts and amperes
B) the recommended overcurrent protection
C) the appliance connected load in volts and watts
D) either a or c
Question
The maximum overcurrent protection for ____ AWG copper conductors is 30 amperes.

A) 10
B) 20
C) 25
D) none of the above
Question
A "unit switch" used as a disconnecting means for an electric clothes dryer shall ____.

A) be horsepower-rated
B) disconnects all the conductors in the appliance
C) have a nema 3r enclosure when installed outdoors
D) both a and b
Question
Describe one accepted grounding means for the frames of electric dryers and electric ranges in new installations.
Question
When electric clothes dryers and electric ranges are cord-and-plug connected, the receptacle and the cord set must be 4-wire, the fourth wire being the separate equipment grounding conductor.
Question
A minimum load of 5500 watts (volt-amperes) or the nameplate rating of the electric clothes dryer, whichever is larger, is used when calculating the dryer load for service-entrance requirements.
Question
All 125-volt, single-phase, 15- and 20-ampere receptacles within ____________________ ft of the outside edge of a sink shall be GFCI protected.
Question
When an existing dryer or electric range is replaced, the NEC ____ the grounded conductor of an existing individual branch circuit to be used for grounding the appliance frame.

A) permits
B) does not permit
Question
A(n) ____ is NOT an acceptable disconnecting means for appliances.

A) circuit-breaker in sight of the appliance
B) circuit-breaker or switch capable of being locked in the off position
C) horsepower-rated switch
D) attachment cord and plug
Question
In accessible attics, exposed cables must be protected by guard strips when ____.

A) they are run across the top of joists
B) they are run across the face of studs
C) they are installed within 7 feet of the floor or floor joists
D) all of the above
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/19
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic
1
Prior to the 1996 NEC, ____ receptacles and cords were permitted. However, now it is mandatory that a separate equipment grounding conductor be installed to ground the frames of electric clothes dryers and electric ranges.

A) 3-wire
B) 16 AWG
C) 4-wire
D) listed
A
2
For most residential electric ____, receptacles and cord sets are rated 30 amperes, 125/250 volts.

A) washers and dryers
B) clothes dryers
C) washers
D) ranges
B
3
A powder room is considered a bathroom if it contains a(n) ____________________ and a toilet, urinal, tub, shower, bidet, or similar plumbing fixture.
basin
4
If an electric clothes dryer or electric range is to be installed in a residence where the dryer branch-circuit wiring had been installed according to pre-1996 NEC rules, how is the dryer frame grounded?
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
5
The special permission that was put into effect in July of 1942 allowed the neutral conductor to serve a dual purpose as the neutral conductor and the ____________________.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
6
NEC 210.52(F) requires a(n) ____________________ in one-family dwellings.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
7
NEC 210.70(A)(3) addresses ____ that are used for storage and attics that contain equipment that might need servicing, such as air-conditioning equipment.

A) powder rooms
B) crawlspace areas
C) basements
D) attics
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
8
When running cables parallel to framing members, at least ____________________ inches must be maintained between the cable and the edge of the framing member.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
9
Electric washer/dryer combinations generally require a ____-ampere branch circuit similar to that required for a typical electric clothes dryer.

A) 10
B) 20
C) 30
D) 40
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
10
The NEC requires that an appliance nameplate show ____.

A) the appliance rating in volts and amperes
B) the recommended overcurrent protection
C) the appliance connected load in volts and watts
D) either a or c
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
11
The maximum overcurrent protection for ____ AWG copper conductors is 30 amperes.

A) 10
B) 20
C) 25
D) none of the above
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
12
A "unit switch" used as a disconnecting means for an electric clothes dryer shall ____.

A) be horsepower-rated
B) disconnects all the conductors in the appliance
C) have a nema 3r enclosure when installed outdoors
D) both a and b
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
13
Describe one accepted grounding means for the frames of electric dryers and electric ranges in new installations.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
14
When electric clothes dryers and electric ranges are cord-and-plug connected, the receptacle and the cord set must be 4-wire, the fourth wire being the separate equipment grounding conductor.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
15
A minimum load of 5500 watts (volt-amperes) or the nameplate rating of the electric clothes dryer, whichever is larger, is used when calculating the dryer load for service-entrance requirements.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
16
All 125-volt, single-phase, 15- and 20-ampere receptacles within ____________________ ft of the outside edge of a sink shall be GFCI protected.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
17
When an existing dryer or electric range is replaced, the NEC ____ the grounded conductor of an existing individual branch circuit to be used for grounding the appliance frame.

A) permits
B) does not permit
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
18
A(n) ____ is NOT an acceptable disconnecting means for appliances.

A) circuit-breaker in sight of the appliance
B) circuit-breaker or switch capable of being locked in the off position
C) horsepower-rated switch
D) attachment cord and plug
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
19
In accessible attics, exposed cables must be protected by guard strips when ____.

A) they are run across the top of joists
B) they are run across the face of studs
C) they are installed within 7 feet of the floor or floor joists
D) all of the above
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 19 flashcards in this deck.