Deck 16: Branch Circuits for the Garage and Outdoors

Full screen (f)
exit full mode
Question
Overhead conductors ____ permitted to be supported by trees.

A) are
B) are not
Use Space or
up arrow
down arrow
to flip the card.
Question
Conductors suitable for use in ____________________ locations will have the letter "W" in their type designation.
Question
Permanent overhead conductor spans are permitted to be supported by live or dead vegetation, such as trees.
Question
Minimum cover requirements for direct-buried cables and raceways under a variety of conditions are given in Table ____________________.
Question
When outdoor receptacles are installed where a cord will be plugged in permanently, such as for decorative lighting, the box cover ____ maintain weatherproof integrity when the cord is plugged in.

A) must
B) need not
Question
The minimum depth for a 120-volt, 15-ampere, GFCI-protected circuit to an outdoor pole light run under a paved driveway is ____.

A) 6 inches
B) 12 inches
C) 18 inches
D) 24 inches
Question
To provide shock protection, low-voltage wiring systems are required by Article 411 to be ____.

A) double-insulated
B) grounded
C) supplied through isolating transformers
D) all of the above
Question
According to NEC 210.52(G), at least ____ receptacle(s) must be installed in an attached residential garage.

A) one
B) two
C) three
D) no receptacles are required
Question
Outdoor lighting fixtures and associated equipment ____ permitted to be supported by trees.

A) are
B) are not
Question
The last sentence of 250.4(A)(5) states that "the earth shall not be considered as an effective ____________________."
Question
Explain why, in colder parts of the country, incandescent fixtures are more suitable than fluorescent for unheated spaces like garages.
Question
Explain the rationale for installing supplemental overcurrent protection, such as a "box cover unit" with a switch and fuse combination, to protect an appliance or utilization equipment such as a garage door opener.
Question
What type of cable is permitted to be used for direct burial applications?

A) Type NMB
B) Type UF
C) Type NMS
D) both a and c
Question
Type UF "underground feeder" cable ____ permitted to be used to supply service entrances.

A) is
B) is not
Question
If you are experiencing too much lamp burnout in your garage door opener, the culprit is probably vibration.
Question
Direct-burial cable is normally required to have a minimum of 24 inches of earth cover. Explain the conditions under which the minimum depth can be reduced to 12 inches for residential occupancies.
Question
Metallic conduit buried underground must be protected against ____.

A) backhoes
B) corrosion
C) galvanic action
D) all of the above
Question
Article ____________________ covers low-voltage lighting systems operating at 30 volts RMS or less.
Question
Explain why a post lamp cannot be grounded only with a local ground rod, but must have a separate grounding equipment conductor going back to the residential service.
Question
The recommended approach to provide adequate lighting in a residential garage is to install one ____-watt lamp on the ceiling above each side of an automobile.

A) 40
B) 60
C) 75
D) 100
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 16: Branch Circuits for the Garage and Outdoors
1
Overhead conductors ____ permitted to be supported by trees.

A) are
B) are not
B
2
Conductors suitable for use in ____________________ locations will have the letter "W" in their type designation.
wet
3
Permanent overhead conductor spans are permitted to be supported by live or dead vegetation, such as trees.
False
4
Minimum cover requirements for direct-buried cables and raceways under a variety of conditions are given in Table ____________________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
When outdoor receptacles are installed where a cord will be plugged in permanently, such as for decorative lighting, the box cover ____ maintain weatherproof integrity when the cord is plugged in.

A) must
B) need not
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The minimum depth for a 120-volt, 15-ampere, GFCI-protected circuit to an outdoor pole light run under a paved driveway is ____.

A) 6 inches
B) 12 inches
C) 18 inches
D) 24 inches
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
To provide shock protection, low-voltage wiring systems are required by Article 411 to be ____.

A) double-insulated
B) grounded
C) supplied through isolating transformers
D) all of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
According to NEC 210.52(G), at least ____ receptacle(s) must be installed in an attached residential garage.

A) one
B) two
C) three
D) no receptacles are required
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Outdoor lighting fixtures and associated equipment ____ permitted to be supported by trees.

A) are
B) are not
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
The last sentence of 250.4(A)(5) states that "the earth shall not be considered as an effective ____________________."
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Explain why, in colder parts of the country, incandescent fixtures are more suitable than fluorescent for unheated spaces like garages.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Explain the rationale for installing supplemental overcurrent protection, such as a "box cover unit" with a switch and fuse combination, to protect an appliance or utilization equipment such as a garage door opener.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
What type of cable is permitted to be used for direct burial applications?

A) Type NMB
B) Type UF
C) Type NMS
D) both a and c
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Type UF "underground feeder" cable ____ permitted to be used to supply service entrances.

A) is
B) is not
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
If you are experiencing too much lamp burnout in your garage door opener, the culprit is probably vibration.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Direct-burial cable is normally required to have a minimum of 24 inches of earth cover. Explain the conditions under which the minimum depth can be reduced to 12 inches for residential occupancies.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Metallic conduit buried underground must be protected against ____.

A) backhoes
B) corrosion
C) galvanic action
D) all of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Article ____________________ covers low-voltage lighting systems operating at 30 volts RMS or less.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Explain why a post lamp cannot be grounded only with a local ground rod, but must have a separate grounding equipment conductor going back to the residential service.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
The recommended approach to provide adequate lighting in a residential garage is to install one ____-watt lamp on the ceiling above each side of an automobile.

A) 40
B) 60
C) 75
D) 100
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.