Deck 15: Luminaires

Full screen (f)
exit full mode
Question
What are the stipulations relevant to lamps in new energy conservation laws that have been enacted in some states?
Use Space or
up arrow
down arrow
to flip the card.
Question
Multiwire branch circuits are defined in NEC® Article 100 as a branch circuit that consists of two or more conductors that have a voltage between them, and a grounded conductor that has equal voltage between it and each ungrounded conductor of the circuit and that is connected to the neutral or grounded conductor of the system.

A) "hot"
B) grounded
C) ungrounded
D) semi-
Question
Beginning with the 2008 edition of the National Electrical Code, the term luminaire is used exclusively. Previous editions of the NEC® used the term luminaire followed by the term in parentheses.

A) lamp
B) lighting source
C) fixture
D) lightbulb
Question
Incandescent, open, or lamps in lampholders; pendant luminaires; and pendant lampholders are not permitted in clothes closets.

A) recessed
B) surface-mounted
C) partially open
D) enclosed
Question
A(n) branch circuit must supply only line-to-neutral loads if the luminaires are connected line-to-neutral.

A) multiwire
B) regular
C) irregular
D) dual-wire
Question
All recessed incandescent luminaires must be equipped with factory-installed thermal protection, unless the luminaire is identified for use and installed in .

A) copper
B) aluminum
C) stainless steel
D) poured concrete
Question
For fluorescent and HID luminaires, the volt-ampere allowance is based on the rating of the .

A) ballast
B) filament
C) tubing
D) phosphor
Question
The installation of luminaires, lighting outlets, and supports is covered in Article 410 of the NEC®. Article 410 sets forth the basic requirements for the installation, commonly referred to as the " "

A) light-up
B) grounding
C) pre-set
D) rough-in
Question
that have the light source completely enclosed are permitted in clothes closets.

A) Incandescent open lamps in lampholders
B) Pendant luminaires
C) Pendant lampholders
D) Surface-mounted or recessed fluorescent luminaires
Question
What are the guidelines for recessed incandescent luminaires not marked IC?
Question
Recessed luminaires are usually supported by that are attached to the luminaires' rough­in box.

A) screws
B) nails
C) adjustable rails
D) outlet boxes
Question
Both Type THWN-2 and Type conductors have an insulation temperature rating of 90 degrees Celsius and generally meet the temperature requirement for connecting luminaires.

A) THW
B) THHN
C) RHW
D) USE
Question
For surface-mounted and pendant-hung luminaires, support rods should be placed so that they extend about in. below the finished ceiling.

A) one
B) two
C) three
D) four
Question
What are the requirements for multiwire branch circuits?
Question
Why are there special requirements for clothes closets?
Question
Type luminaires are permitted to be installed in direct contact with thermal insulation.

A) IIC
B) IC
C) RC
D) XC
Question
Recessed luminaires have to be securely fastened to the ceiling framing members using bolts, screws, or .

A) tacks
B) rivets
C) grid elements
D) flexible cables
Question
It is necessary that the illumination of a building comply with energy codes. These codes usually evaluate the illumination on the basis of the average per square foot (meter) of illumination load.

A) watts
B) volt-amperes
C) lumens
D) candelas
Question
Most fluorescent lamps with energy savings ballasts, compact fluorescent lamps (CFLs), LEDs, and halogen lamps meet the high-efficacy requirement. do not.

A) Most fluorescent lamps with energy savings ballasts
B) Conventional incandescent lamps
C) Compact fluorescent lamps
D) Halogen Lamps
Question
Describe the rules governing the disconnecting means for fluorescent luminaires.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Luminaires
1
What are the stipulations relevant to lamps in new energy conservation laws that have been enacted in some states?
The new laws in these states simply require that lamps in permanently installed luminaires:
-have high efficacy rating (high lumens per watt), or
-be controlled by occupancy sensors, or
-have a combination of lamp efficacy, occupancy sensor control, and/or dimmers.
Cord-connected floor or table lamps are not governed by current energy conservation laws. Most fluorescent lamps with energy savings ballasts, compact fluorescent lamps (CFLs), LEDs, and halogen lamps meet this high-efficacy requirement. Conventional incandescent lamps do not.
2
Multiwire branch circuits are defined in NEC® Article 100 as a branch circuit that consists of two or more conductors that have a voltage between them, and a grounded conductor that has equal voltage between it and each ungrounded conductor of the circuit and that is connected to the neutral or grounded conductor of the system.

A) "hot"
B) grounded
C) ungrounded
D) semi-
C
3
Beginning with the 2008 edition of the National Electrical Code, the term luminaire is used exclusively. Previous editions of the NEC® used the term luminaire followed by the term in parentheses.

A) lamp
B) lighting source
C) fixture
D) lightbulb
C
4
Incandescent, open, or lamps in lampholders; pendant luminaires; and pendant lampholders are not permitted in clothes closets.

A) recessed
B) surface-mounted
C) partially open
D) enclosed
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
A(n) branch circuit must supply only line-to-neutral loads if the luminaires are connected line-to-neutral.

A) multiwire
B) regular
C) irregular
D) dual-wire
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
All recessed incandescent luminaires must be equipped with factory-installed thermal protection, unless the luminaire is identified for use and installed in .

A) copper
B) aluminum
C) stainless steel
D) poured concrete
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
For fluorescent and HID luminaires, the volt-ampere allowance is based on the rating of the .

A) ballast
B) filament
C) tubing
D) phosphor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
The installation of luminaires, lighting outlets, and supports is covered in Article 410 of the NEC®. Article 410 sets forth the basic requirements for the installation, commonly referred to as the " "

A) light-up
B) grounding
C) pre-set
D) rough-in
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
that have the light source completely enclosed are permitted in clothes closets.

A) Incandescent open lamps in lampholders
B) Pendant luminaires
C) Pendant lampholders
D) Surface-mounted or recessed fluorescent luminaires
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
What are the guidelines for recessed incandescent luminaires not marked IC?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Recessed luminaires are usually supported by that are attached to the luminaires' rough­in box.

A) screws
B) nails
C) adjustable rails
D) outlet boxes
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Both Type THWN-2 and Type conductors have an insulation temperature rating of 90 degrees Celsius and generally meet the temperature requirement for connecting luminaires.

A) THW
B) THHN
C) RHW
D) USE
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
For surface-mounted and pendant-hung luminaires, support rods should be placed so that they extend about in. below the finished ceiling.

A) one
B) two
C) three
D) four
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
What are the requirements for multiwire branch circuits?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Why are there special requirements for clothes closets?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Type luminaires are permitted to be installed in direct contact with thermal insulation.

A) IIC
B) IC
C) RC
D) XC
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Recessed luminaires have to be securely fastened to the ceiling framing members using bolts, screws, or .

A) tacks
B) rivets
C) grid elements
D) flexible cables
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
It is necessary that the illumination of a building comply with energy codes. These codes usually evaluate the illumination on the basis of the average per square foot (meter) of illumination load.

A) watts
B) volt-amperes
C) lumens
D) candelas
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Most fluorescent lamps with energy savings ballasts, compact fluorescent lamps (CFLs), LEDs, and halogen lamps meet the high-efficacy requirement. do not.

A) Most fluorescent lamps with energy savings ballasts
B) Conventional incandescent lamps
C) Compact fluorescent lamps
D) Halogen Lamps
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Describe the rules governing the disconnecting means for fluorescent luminaires.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.