Deck 13: System Protection
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
Play
Full screen (f)
Deck 13: System Protection
1
The three major types of circuit breakers are air, oil, and .
A) water
B) vacuum
C) alcohol
D) mercury
A) water
B) vacuum
C) alcohol
D) mercury
B
2
A system containing only is the easiest situation to coordinate.
A) main circuit breakers
B) branch-circuit breakers
C) ground-fault protectors
D) fuses
A) main circuit breakers
B) branch-circuit breakers
C) ground-fault protectors
D) fuses
D
3
When an electric arc occurs in air, gas molecules in the air .
A) become polarized
B) become ionized
C) form dimers
D) start a chain reaction
A) become polarized
B) become ionized
C) form dimers
D) start a chain reaction
B
4
One method used by circuit breakers to sense circuit current is to connect a(n) in series with the load.
A) battery
B) ammeter
C) coil
D) resistor
A) battery
B) ammeter
C) coil
D) resistor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
What is an auxiliary switch?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
In magnetic-type circuit breakers , there is time delay in the opening of the contacts when an overload occurs.
A) zero
B) very little
C) medium
D) very high
A) zero
B) very little
C) medium
D) very high
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
air circuit breakers are used in low-voltage (600 volts or less), low-current circuits.
A) Low-voltage
B) Molded-case
C) Medium-voltage
D) High-voltage
A) Low-voltage
B) Molded-case
C) Medium-voltage
D) High-voltage
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Classify low oil (also called oil poor) circuit breakers.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
Circuit breakers actually have two different current ratings. One is the trip rating, and the other is the rating.
A) fuse
B) ground
C) selective
D) interrupt
A) fuse
B) ground
C) selective
D) interrupt
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
There are two basic types of oil circuit breakers, the full tank or dead tank type and the low oil or type.
A) half tank
B) oil poor
C) low tank
D) oil-free
A) half tank
B) oil poor
C) low tank
D) oil-free
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Low-voltage power circuit breakers commonly have set(s) of contacts.
A) one
B) two
C) three
D) four
A) one
B) two
C) three
D) four
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The is the point at which a breaker responds to a short-circuit current through a magnetically actuated trip arrangement.
A) long-time delay
B) frame size
C) instantaneous pickup current
D) instantaneous opening
A) long-time delay
B) frame size
C) instantaneous pickup current
D) instantaneous opening
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
A ground-fault protective device consists of a ground-fault sensor and a .
A) relay
B) circuit breaker
C) transformer
D) fuse
A) relay
B) circuit breaker
C) transformer
D) fuse
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
What are some required and recommended uses for ground-fault protection devices?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
trips are used to open the circuit breaker contacts by energizing the solenoid from an external source.
A) Shunt
B) Fuse
C) Interrupt
D) Coil
A) Shunt
B) Fuse
C) Interrupt
D) Coil
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Coordination among multiple ground-fault protectors is achieved by using a lower setting and progressively shorter time settings on each of the downstream devices.
A) trip
B) interrupt
C) fuse
D) arc
A) trip
B) interrupt
C) fuse
D) arc
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
What is indicated by the long-time delay portion of the time-current curve?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
means that when an overload or fault condition occurs, only the part of the electrical system that is in jeopardy is disconnected.
A) Dependent coordination
B) Ground-fault protection
C) Selective coordination
D) System protection
A) Dependent coordination
B) Ground-fault protection
C) Selective coordination
D) System protection
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
The amount of current that will flow during a short-circuit condition is determined by two factors: the voltage and the ____.
A) impedance
B) power
C) coil strength
D) fuse strength
A) impedance
B) power
C) coil strength
D) fuse strength
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
What is the mechanism behind the operation of a thermal circuit breaker?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck