Deck 5: Bonding

Full screen (f)
exit full mode
Question
Exposed structural metal that is interconnected to form a metal building frame that is not intentionally grounded and is likely to become ___________________ is required to be bonded.
Use Space or
up arrow
down arrow
to flip the card.
Question
"Normal" bonding methods are considered adequate for most circuits.
Question
Special assured bonding is required for some systems and circuits, including the service (250.92), over-____ volts-to-ground circuits (250.97), and hazardous locations (250.100).

A) 50
B) 100
C) 200
D) 250
Question
The term "____" is defined in NEC Article 100 as "connected to establish electrical continuity and conductivity."

A) bonded (bonding)
B) bended (bending)
C) shunted (shunting)
D) grounded (grounding)
Question
When bonding metal equipment is installed remotely from the service equipment, the metal raceway and meter enclosure must be bonded to the ____.

A) current transformer
B) grounding electrode
C) system neutral
D) transformer
Question
Bonding is required to be provided where necessary to ensure electrical continuity and the capacity to conduct safely any ____________________ likely to be imposed.
Question
According to the Code, which of the following is found in a Class II location?

A) flammable vapors
B) combustible dust
C) fibers
D) flyings
Question
Metal water pipes and structural metal qualify as grounding electrodes.
Question
All metal enclosures containing an ungrounded ("hot") service conductor are bonded together by use of the grounded ____ conductor.

A) supply-side
B) service
C) exit
D) entrance
Question
It is not uncommon for electrical designers to require an equipment grounding conductor to be installed in every raceway even though the raceway is metal and recognized in the NEC as an equipment grounding conductor.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Bonding
1
Exposed structural metal that is interconnected to form a metal building frame that is not intentionally grounded and is likely to become ___________________ is required to be bonded.
energized
2
"Normal" bonding methods are considered adequate for most circuits.
True
3
Special assured bonding is required for some systems and circuits, including the service (250.92), over-____ volts-to-ground circuits (250.97), and hazardous locations (250.100).

A) 50
B) 100
C) 200
D) 250
D
4
The term "____" is defined in NEC Article 100 as "connected to establish electrical continuity and conductivity."

A) bonded (bonding)
B) bended (bending)
C) shunted (shunting)
D) grounded (grounding)
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
When bonding metal equipment is installed remotely from the service equipment, the metal raceway and meter enclosure must be bonded to the ____.

A) current transformer
B) grounding electrode
C) system neutral
D) transformer
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
Bonding is required to be provided where necessary to ensure electrical continuity and the capacity to conduct safely any ____________________ likely to be imposed.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
According to the Code, which of the following is found in a Class II location?

A) flammable vapors
B) combustible dust
C) fibers
D) flyings
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Metal water pipes and structural metal qualify as grounding electrodes.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
All metal enclosures containing an ungrounded ("hot") service conductor are bonded together by use of the grounded ____ conductor.

A) supply-side
B) service
C) exit
D) entrance
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
It is not uncommon for electrical designers to require an equipment grounding conductor to be installed in every raceway even though the raceway is metal and recognized in the NEC as an equipment grounding conductor.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.